Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
No Bots, Just Experts
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C2WG36TE-DQME2L66/C 60A 3-Phase Switched Rack PDU
Overview
The Server Technology C2WG36TE-DQME2L66/C is a 0U vertical rackmount switched PDU built for data center and server room racks that need per-outlet power control on a 3-phase 60A circuit. With 36 outlets delivering 120V AC output, this unit is sized for dense equipment racks running mixed loads — servers, switches, storage arrays — where individual outlet switching matters more than raw outlet count alone. The C2WG36TE-DQME2L66/C mounts vertically along the rack rail, keeping outlets accessible down the full height of the cabinet instead of consuming U-space that could otherwise hold compute or networking gear.
Key Features
- 36 Outlets: Enough outlet density to power a fully loaded rack of servers, switches, and PDUs downstream without daisy-chaining extra strips — fewer cable runs, cleaner rack cabling.
- 3-Phase Input: Balances load across all three phases instead of overloading a single-phase circuit, which is the standard approach for high-density racks pulling more current than a single-phase feed can safely carry.
- 60A Input Current: Supports a higher-draw rack population than typical 20A or 30A strips, reducing the need to split a single rack across multiple lower-amperage PDUs.
- 120V AC Output: Matches standard US data center equipment power inputs, so no step-down or additional conversion hardware is needed for common server and network gear.
- 0U Rackmount, Vertical Orientation: Installs in the space between the rack posts and the cabinet frame rather than occupying rack unit space — every U stays available for compute, storage, or networking equipment.
- 10ft Cord Length: Long enough to reach overhead or underfloor power whips in most cabinet layouts without an extension, reducing the chance of a mid-install length problem.
- Switched Outlet Control: Individual outlet switching lets you power-cycle a single hung server or network device remotely instead of walking the data center floor, and lets you stagger equipment power-up to avoid inrush current spikes across the whole rack.
Integration & Compatibility
The C2WG36TE-DQME2L66/C's vertical 0U form factor is designed to integrate into standard server rack enclosures alongside the rest of a rack's power chain — feeding downstream network switches, servers, and storage. Pairing it with rack-mounted network components or a network video recorder deployment in a shared equipment room is a common configuration where centralized, switchable power control simplifies remote troubleshooting. For broader power planning across multiple racks, a PoE and power planning guide is a useful reference before finalizing circuit sizing. The C2WG36TE-DQME2L66/C (often searched as C2WG36TE DQME2L66/C) fits into the broader Server Technology PDU lineup, which spans different outlet counts and phase configurations for racks of varying density. Facilities standardizing on rack power distribution units across a data hall should confirm phase and amperage requirements against actual rack load before ordering, since 3-phase 60A service is a different electrical circuit than single-phase alternatives in the same family. If your rack population is lighter, a lower-amperage or single-phase variant in the same product family is worth evaluating instead of over-provisioning a 60A 3-phase feed. For racks requiring physical security monitoring alongside power infrastructure, coordinating with a camera selection guide for server room coverage rounds out the room-level deployment plan.
What's in the Box
Contents beyond the C2WG36TE-DQME2L66/C PDU unit itself were not specified in available documentation.
Frequently Asked Questions
Q: How many outlets does the C2WG36TE-DQME2L66/C have?
A: The C2WG36TE-DQME2L66/C provides 36 outlets on a single 3-phase 60A input.
Q: What input current and phase configuration does the C2WG36TE-DQME2L66/C use?
A: It runs on a 3-phase circuit rated for 60A input current, with 120V AC output at the outlets.
Q: What rack space does the C2WG36TE-DQME2L66/C occupy?
A: It's a 0U vertical rackmount unit, mounted along the rack posts rather than consuming horizontal rack unit space.
Q: How long is the power cord on the C2WG36TE-DQME2L66/C?
A: The unit ships with a 10ft cord.
Q: Is the C2WG36TE-DQME2L66/C a switched PDU?
A: Yes, it is a switched PDU, indicated by the outlet control designation in its model configuration.

The C2WG36TE-DQME2L66/C is a 3-phase 60A switched PDU with 36 outlets — that's a lot of switchable outlet density on one circuit, and it tells you this is meant for a full rack of mixed equipment rather than a half-populated cabinet.
Technical Highlights:
- 36 Outlets on 3-Phase 60A Input: Balancing load across three phases at 60A lets you power a dense rack without splitting it across two or three lower-amp PDUs — fewer power paths to manage per rack.
- 0U Vertical Rackmount: Mounting vertically along the rack posts means all 36 outlets stay accessible without eating into usable rack unit space — every U in the cabinet stays available for compute or network gear.
- 120V AC Output, 10ft Cord: Standard 120V output matches typical US server and network equipment power inputs, and the 10ft cord reaches most overhead or underfloor whip drops without an extension.
Deployment Considerations:
- Confirm your facility's 3-phase 60A circuit availability before ordering — this isn't a drop-in replacement for a single-phase 20A or 30A strip, it's a different electrical service.
- Switched outlet control means remote power-cycling per outlet, which is worth the added cost over a basic PDU if you're managing racks that aren't staffed around the clock.
This is the right call for a data center or colocation rack running a full 42U of mixed servers and switches on 3-phase power, where per-outlet remote power-cycling saves a truck roll for a single hung device. If your rack is lightly populated or only has single-phase service, look at a lower-amperage or single-phase model in the same C2W family instead.
Compare with similar
Server Technology Switched Pops Primary - C2WG36TE-DQME2L66/C
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology