Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C2WG36TE-2CAF2M66/GB Switched Rack PDU
Overview
The Server Technology C2WG36TE-2CAF2M66/GB is a switched POPS (Per Outlet Power Sensing) primary PDU built for data center racks that need granular outlet-level control across a mixed device load. It pairs 24 standard C13 outlets with 12 CX ALT-BRANCH HDOT outlets on a 208V, 3-branch circuit configuration — a layout aimed at racks running a combination of standard IEC power cords and higher-density HDOT (Horizontal Display Outlet Technology) connections. This is a primary unit, meaning it's positioned as the main distribution point in a primary/secondary PDU pairing rather than a standalone strip. If you're specifying rack power for a colo cage, server room, or telecom closet where remote outlet switching and load visibility matter, the C2WG36TE-2CAF2M66/GB fits that role.
Key Features
- Switched, per-outlet control: Individual outlets can be remotely powered on/off/rebooted — useful when a hung server or network device needs a hard power cycle without a technician walking the row.
- 24x C13 outlets: Covers standard IEC C14-cord servers, switches, and storage arrays — the most common rack power connector, so compatibility with existing PDU cabling is straightforward.
- 12x CX ALT-BRANCH HDOT outlets: HDOT outlets add a physical locking mechanism that keeps power cords seated during vibration or accidental tugging — worth having on any rack that sees frequent hands-on maintenance.
- 208V input: Matches standard North American commercial/data-center 3-phase or split-phase distribution, letting the unit slot into existing 208V rack power infrastructure without a step-down.
- 3-branch (3BR) circuit design: Splits the 36 outlets across three separate branch circuits, so a single breaker trip or overload on one branch doesn't take down every device on the PDU — meaningful for racks mixing critical and non-critical loads.
- TAA compliance: Confirms the unit meets Trade Agreements Act sourcing rules, a hard requirement for federal and federally-funded procurement where non-compliant hardware gets rejected during purchase review.
Integration & Compatibility
As a primary POPS unit, the C2WG36TE-2CAF2M66/GB is designed to work within Server Technology's Sentry power management architecture, which typically pairs a primary PDU with secondary units for extended rack coverage. Confirm your specific secondary-unit pairing and network management module needs against your existing power distribution units deployment before ordering, since primary/secondary compatibility is model-specific. For racks also running IP cameras, NVRs, or access control hardware, this PDU sits alongside a broader network video recorder or server rack build — pairing outlet-level power cycling with your existing remote management stack cuts truck rolls for stuck devices. Review a PoE and rack power planning guide before finalizing branch allocation across mixed camera, switch, and server loads.
Frequently Asked Questions
Q: Is the C2WG36TE-2CAF2M66/GB TAA compliant?
A: Yes, this unit is TAA compliant, making it eligible for federal and federally-funded procurement that requires Trade Agreements Act sourcing.
Q: What outlet types does the C2WG36TE-2CAF2M66/GB provide?
A: It provides 24 standard C13 outlets plus 12 CX ALT-BRANCH HDOT locking outlets, for a total of 36 outlets across three branch circuits.
Q: What input voltage does this PDU require?
A: It's designed for 208V input power.
Q: Is the C2WG36TE-2CAF2M66/GB a primary or secondary PDU unit?
A: It's a primary unit (PRIMARY PRO2 in the product designation), intended as the main distribution point in a Server Technology primary/secondary PDU configuration.

The C2WG36TE-2CAF2M66/GB is a 36-outlet switched PDU, and the outlet mix is the detail worth pausing on: 24 C13 plus 12 CX ALT-BRANCH HDOT, split across a 3-branch 208V circuit.
Technical Highlights:
- 24x C13 + 12x CX HDOT outlets: covers standard IEC-corded gear and locking HDOT connections in one strip, so you're not running two separate PDU types for mixed equipment racks.
- 3-branch (3BR) circuit split: isolates faults so one overloaded branch doesn't drop all 36 outlets at once.
- 208V input: lines up with standard commercial data-center power without a transformer or step-down in the path.
Deployment Considerations:
- This is a primary (PRIMARY PRO2) unit — confirm your secondary-unit pairing and network module before ordering if you're extending coverage to a second half of the rack.
- HDOT outlets require HDOT-compatible cords to get the locking benefit; standard C14 cords will seat fine in the C13 side but won't lock on the CX ALT-BRANCH ports.
I'd spec the C2WG36TE-2CAF2M66/GB for a federal or federally-funded data center buildout where TAA compliance is a hard gate and the rack mixes standard servers with HDOT-terminated equipment on a 208V 3-phase feed.
Compare with similar
Server Technology Switched Pops Primary - C2WG36TE-2CAF2M66/GB
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology