Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: PMG4S-A
UPC: 731304265139
Condition: New
Write a Review 33% OFF

APC by Schneider Electric Surgearrest Panelmount 480/277V 160KA with Surge Counter - PMG4S-A

APC by Schneider Electric PMG4S-A Panel-Mount Surge Suppressor 480/277V 160kAOverviewThe PMG4S-A is a hardwired panel-mount surge suppressor rated for…

$3,075.00 $2,045.99 SAVE $1029
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric Surgearrest Panelmount 480/277V 160KA with Surge Counter - PMG4S-A

$3,075.00
$2,045.99

Overview

SKU: PMG4S-A
UPC: 731304265139
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric PMG4S-A Panel-Mount Surge Suppressor 480/277V 160kA

Overview

The PMG4S-A is a hardwired panel-mount surge suppressor rated for 480/277V three-phase wye distribution systems — the supply voltage found in most mid-to-large commercial buildings, manufacturing facilities, and data-center utility rooms. At 160,000A peak let-through current in normal mode, it is sized for sites where a utility-side strike or capacitor-bank switching event would otherwise damage downstream power distribution equipment, security infrastructure, or building automation hardware. The built-in surge counter provides a verifiable maintenance record: when the counter climbs, you have documented evidence of cumulative stress on the device without pulling meters or guessing. The grey steel enclosure measures 316 × 152 × 356 mm, designed for direct panel or wall mounting adjacent to the service entrance or main distribution board.

Compatibility

Designed for 480/277V four-wire wye (WYE) services operating at 50–60 Hz — the standard utility delivery voltage across North American commercial and light-industrial facilities. The PMG4S-A installs at the service entrance or main distribution panel to protect the full downstream load, making it appropriate upstream of PoE switch panels, UPS arrays, and building-wide low-voltage systems. It is not rated for 208/120V wye systems or 480V delta services — confirm your service configuration before ordering. The 30 dB EMI/RFI attenuation also benefits sensitive analog and IP security cameras and access control equipment fed from the same distribution panel.

Installation Notes

Operating temperature range is -20°C to 65°C; the unit can be pre-installed in unconditioned electrical rooms or exterior utility cabinets that stay within that window. Storage temperature extends to -40°C. Humidity tolerance runs 0–95% non-condensing for both operating and storage. The on/off disconnect switch is built in, allowing the SPD branch to be isolated for service without shutting down the panel. Certifications include UL 1449 (TVSS), UL 1283, and cUL — required for most AHJ sign-offs on commercial electrical installations. Verify conduit and conductor sizing against NEC Article 285 requirements for SPD branch circuits before rough-in.

Specifications
Nominal input voltage: 480 V
AC input frequency: 50 - 60 Hz
Peak current, normal mode: 160000 A
Peak current, common mode: 80000 A
Product colour: Grey
EMI/RFI noise filtering: 30 dB
On/off switch: Yes
Weight: 8.64 kg
Operating temperature (T-T: -20 - 65 °C
Storage temperature (T-T: -40 - 65 °C
Operating relative humidity (H-H: 0 - 95%
Storage relative humidity (H-H: 0 - 95%
Certification: UL 1283, UL 1449, cUL, UL 1449 TVSS
Dimensions (WxDxH: 316 x 152 x 356 mm
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources