FLIR 427-0045-01-00 Fixed Thermal Security Camera
Overview
The FLIR 427-0045-01-00 is a fixed thermal security camera built around an uncooled VOx microbolometer detector, delivering 320x240 thermal resolution for perimeter and site security applications where detecting a heat signature matters more than resolving facial detail. This is a detection-and-classification tool, not a license-plate camera — it is built to answer "is something there" in total darkness, heavy smoke, or fog, conditions where visible-light cameras lose usefulness entirely. The 427-0045-01-00 (often searched as 427 0045 01 00) targets commercial and industrial sites — fence lines, tank farms, substations, rail yards — where thermal contrast, not color detail, drives the detection decision.
Key Features
- 320x240 Uncooled VOx Microbolometer: a thermal-specific sensor architecture that reads heat differential rather than visible light, so the 427-0045-01-00 keeps working through smoke, fog, and complete darkness where a standard IR-illuminated camera goes blind past its IR throw distance.
- NETD <50 mK Thermal Sensitivity: sub-50-millikelvin sensitivity means the sensor resolves small temperature differences between a person or vehicle and the background — the spec that actually determines whether a distant heat signature registers as a detectable object instead of noise.
- 30 Hz (US) / 8.3 Hz (export) Frame Rate: the domestic 30 Hz frame rate delivers smooth, video-rate thermal output for live monitoring and motion-based analytics; the 8.3 Hz export variant reflects ITAR/export-control frame-rate limits on thermal imaging hardware shipped outside the US.
- IP66 Rating: sealed against dust ingress and high-pressure water jets, so the 427-0045-01-00 mounts outdoors — on a pole, wall, or fence line — without a separate enclosure. IP66 covers rain and washdown spray; it is not a submersion rating.
- -50°C to 75°C Operating Range: an operating window this wide covers Arctic cold and desert heat without a heater/blower kit, which matters for unattended perimeter installs where nobody is checking on the camera daily.
- PoE+ or 24 VAC Power: run a single Cat5e/Cat6 cable for both power and data via PoE+, or wire 24 VAC where existing site power infrastructure already uses that standard — flexibility that simplifies retrofits into sites with established conduit runs.
- ONVIF Profile S, RTSP, H.264: standards-based streaming and control means the 427-0045-01-00 integrates into ONVIF-compliant VMS platforms without a proprietary bridge, and H.264 keeps bandwidth and storage load predictable on existing recording infrastructure.
- NDAA Compliant: clears Section 889 procurement restrictions, which is a hard requirement for federal, state, and many municipal and critical-infrastructure bids where non-compliant hardware is disqualified outright.
Integration & Compatibility
ONVIF Profile S support means the 427-0045-01-00 registers as a standard video source in any ONVIF-compliant VMS, with RTSP available as a direct stream-pull fallback for platforms that prefer it. Because this is a thermal-only fixed camera, most deployments pair it with a visible-light camera covering the same field of view for identification purposes once the thermal unit flags activity — thermal detects, visible-light confirms. For sites building out full perimeter coverage, pairing thermal units with an NVR sized for the added channel count and a PoE switch with enough budget per port keeps power delivery simple on a single cable run. Review the rest of the FLIR camera lineup for visible-light pairing options, browse the broader outdoor IP camera category for complementary fixed and PTZ units, and check a PoE planning guide before finalizing switch and cable-run budgets on multi-camera thermal deployments.
Frequently Asked Questions
Q: Is the FLIR 427-0045-01-00 NDAA compliant?
A: Yes, the 427-0045-01-00 is NDAA compliant, meeting Section 889 procurement requirements for federal and state agencies.
Q: What resolution does the 427-0045-01-00 thermal sensor capture?
A: The 427-0045-01-00 uses a 320x240 uncooled VOx microbolometer detector.
Q: What frame rate does the 427-0045-01-00 run at?
A: 30 Hz for US-market units; export units are limited to 8.3 Hz per export control regulations.
Q: Can the 427-0045-01-00 be mounted outdoors?
A: Yes. It carries an IP66 rating for dust and water-jet ingress protection and an operating range of -50°C to 75°C.
Q: How is the 427-0045-01-00 powered?
A: It accepts PoE+ or 24 VAC power.
Q: Does the 427-0045-01-00 support ONVIF?
A: Yes, it supports ONVIF Profile S along with RTSP and H.264 streaming.
The 427-0045-01-00 is a thermal-only fixed camera, and the spec that tells you most of what you need to know is the NETD rating: under 50 mK. That's the sensitivity threshold, and it's what separates a camera that reliably picks a person out of a warm fence line at range from one that just shows a blurry hot blob.
Technical Highlights:
- 320x240 VOx Microbolometer: uncooled thermal sensors this class trade raw resolution for reliability and lower power draw compared to cooled thermal — no cryocooler to maintain, which matters on unattended perimeter installs.
- NETD <50 mK: sub-50-millikelvin sensitivity is the number that determines whether a distant heat source resolves as a detectable target instead of thermal noise — this is the spec to check before committing to a detection range claim.
- -50°C to 75°C Operating Range: a 125°C operating window covers both sub-Arctic winters and desert summers without supplemental heating or cooling hardware, which keeps unattended remote sites simpler to maintain.
Deployment Considerations:
- Export units are capped at 8.3 Hz frame rate versus 30 Hz domestic — confirm which variant you're quoting before assuming smooth video-rate output, since export-controlled thermal frame rates are a hard regulatory limit, not a firmware setting.
- This is a thermal-only unit with no stated visible-light sensor — plan on pairing it with a separate visible camera on the same pole or FOV if your use case needs identification-grade footage after a thermal detection event.
Reach for the 427-0045-01-00 on perimeter and critical-infrastructure sites — fence lines, substations, tank farms, rail corridors — where NDAA-compliant thermal detection through darkness, smoke, or fog is the requirement and visible-light identification is handled by a second camera.