APC by Schneider Electric Smart-ups RT 15KVA RM 230V - SURT15KRMXLI

APC by Schneider Electric SURT15KRMXLI Smart-UPS RT 15kVA Rackmount Online UPS 230VOverviewThe SURT15KRMXLI is a 15 kVA / 12,000 W double-conversion o…

$26,965.00 $17,475.99 SAVE $9489
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric Smart-ups RT 15KVA RM 230V - SURT15KRMXLI

$26,965.00
$17,475.99

Overview

SKU: SURT15KRMXLI
UPC: 731304255727
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric SURT15KRMXLI Smart-UPS RT 15kVA Rackmount Online UPS 230V

Overview

The SURT15KRMXLI is a 15 kVA / 12,000 W double-conversion online UPS designed for rack-mounted critical infrastructure — server rooms, network closets, broadcast environments, and industrial control systems that cannot tolerate even a momentary transfer gap. Unlike line-interactive or standby designs, the double-conversion topology keeps connected equipment running off a continuously regenerated sine wave output at all times, so there is zero transfer time to battery during a utility failure. If your load is sensitive to voltage transients, frequency deviations, or waveform distortion, this architecture eliminates all three simultaneously.

Built for rackmount UPS systems, the SURT15KRMXLI delivers 12,000 W of real power capacity at a 0.8 power factor — meaningful headroom for high-density server and storage loads that draw close to rated wattage rather than just VA. Output voltage is selectable between 220 V and 240 V to match regional distribution requirements across European, Middle Eastern, and international installations.

Key Features

  • Double-Conversion (Online) Topology: The inverter is always in the power path — zero transfer time to battery means connected equipment never experiences a switchover event. For loads running real-time databases, VoIP systems, or industrial PLCs, this is the only topology that guarantees uninterrupted, conditioned power regardless of input quality.
  • 15 kVA / 12,000 W Output Capacity: At a 0.8 power factor, you get 12 kW of usable wattage — enough to support a dense rack of servers, storage arrays, and networking gear without derating headroom. Size your actual load to no more than 80% of rated watts (9,600 W) for thermal margin and runtime buffer.
  • Pure Sine Wave Output: Output waveform is a true sine wave — not a stepped or simulated approximation. Active PFC power supplies, variable frequency drives, and medical-grade equipment all require this; quasi-square wave outputs from cheaper UPS units can cause premature failure or erratic behavior in these loads.
  • 95% Efficiency: Operating at 95% efficiency in online mode is notably high for a double-conversion unit at this capacity. Lower efficiency translates directly to heat dissipation and operating cost — a less efficient 15 kVA unit running 24/7 can add hundreds of dollars annually in wasted energy. At this efficiency rating, the gap between double-conversion protection and line-interactive cost-of-ownership narrows substantially.
  • Wide Input Frequency Range (40–70 Hz): Accepts input frequency between 40 and 70 Hz, making the SURT15KRMXLI compatible with generator power as well as unstable utility grids. Generators often drift outside the 47–53 Hz band under load — a unit with a narrow frequency window will transfer to battery unnecessarily, cycling the battery and reducing its lifespan.
  • 3:1 Crest Factor Handling: A crest factor tolerance of 3:1 means the UPS can supply short-duration peak currents three times the RMS load current — important for loads with high inrush, such as motors, large switching power supplies, and laser printers. Under-specified UPS units clip these peaks, causing distorted waveforms that damage equipment over time.
  • Emergency Power Off (EPO): Hardwired EPO support allows integration with building management systems or emergency shutoff panels. In a fire suppression event or emergency evacuation, a single EPO signal drops all connected loads immediately — a code requirement in many data center and raised-floor environments.
  • C19 Outlet Configuration: Output connections are IEC C19 couplers, rated for 16 A per outlet. C19 is the standard connector for high-density server PDUs and rack-mounted equipment — if your downstream distribution uses C19/C20 pairs, no adapters are needed. Verify outlet count against your load count before finalizing the installation.
  • Audible Alarm with Auto-Restart: The unit provides audible alarm notification for fault conditions and supports auto-restart after utility restoration — no manual intervention required to resume operation after a power event. In unmanned equipment rooms, auto-restart prevents extended downtime from a brief outage that resolved before anyone checked.
  • Surge Protection: Integrated surge suppression protects connected equipment from transient voltage spikes on the input line, adding a layer of protection beyond what the double-conversion topology itself provides during normal operation.
  • 50 dB Noise Level: At 50 dB(A), the SURT15KRMXLI is audible in a quiet office environment but within normal range for a UPS of this capacity. For installations in occupied spaces adjacent to server rooms, factor this into your acoustic planning — wall penetration or a dedicated closet eliminates the concern.
  • Output Frequency Regulation (50/60 Hz): Output frequency is regulated to either 50 or 60 Hz regardless of input frequency variation, ensuring downstream equipment receives stable frequency even when running on generator or unstable grid. This decouples your load from input quality entirely — the definition of true online conditioning.

Integration and Compatibility

The SURT15KRMXLI is designed for integration into rack infrastructure serving network and server environments. The single-phase 230 V output targets European and international markets where three-phase input is distributed to single-phase rack-level UPS units. The C19 outlet format pairs directly with rack PDUs in standard data center deployments.

For systems requiring centralized power management, the Smart-UPS RT platform supports external management cards (sold separately) for SNMP, Modbus, and building automation integration — verify compatibility with your specific management card against the SURT15KRMXLI's expansion bay before ordering. If you are designing a monitored power chain, pair this unit with a compatible network management card to enable remote monitoring, alerting, and scheduled shutdowns.

Input frequency tolerance of 40–70 Hz makes this unit suitable for generator-fed installations common in critical power applications such as healthcare facilities, broadcast infrastructure, and industrial automation. The EPO interface should be mapped to your facility's emergency systems during commissioning — consult local electrical code for EPO wiring requirements and enclosure specifications.

Refer to APC's Smart-UPS product family for the full range of capacity options if 15 kVA is above or below your calculated load requirements. Proper UPS sizing starts with a measured load audit — not nameplate ratings — since actual server draw is typically 40–60% of rated power supply capacity.

Frequently Asked Questions

Q: What is the difference between the double-conversion topology of the SURT15KRMXLI and a line-interactive UPS?

A: The SURT15KRMXLI uses double-conversion (online) topology, meaning the inverter is always active and connected equipment always runs off the regenerated sine wave output — transfer time to battery is zero. A line-interactive UPS only engages its inverter during a power failure, resulting in a 2–8 ms transfer gap. For loads sensitive to any power interruption or waveform distortion, double-conversion is the correct choice.

Q: What is the real power output of the SURT15KRMXLI in watts?

A: The SURT15KRMXLI delivers 12,000 W (12 kW) of real power at a 0.8 power factor. When sizing your load, keep actual draw at or below 9,600 W (80% of rated watts) to maintain thermal headroom and maximize battery runtime during outages.

Q: Does the SURT15KRMXLI support generator input?

A: Yes. The input frequency range of 40–70 Hz accommodates generator power, which often drifts outside the standard 50/60 Hz ±3 Hz band under varying load conditions. The double-conversion architecture isolates the output from input frequency instability entirely, so connected equipment sees clean, regulated 50 or 60 Hz regardless of generator behavior.

Q: What output voltage options are available on the SURT15KRMXLI?

A: Output voltage is adjustable between 220 V and 240 V, covering the standard single-phase distribution voltages used across European, Middle Eastern, African, and Asia-Pacific markets. Select the output voltage during commissioning to match your downstream equipment's rated input voltage.

Q: What outlet type does the SURT15KRMXLI use?

A: Output connections are IEC C19 couplers, the standard high-current (16 A) outlet used in data center and rack environments. These mate directly with C20 inlets on rack PDUs, servers, and networking equipment without adapters.

Q: Does the SURT15KRMXLI have an Emergency Power Off (EPO) feature?

A: Yes. The SURT15KRMXLI includes a hardwired EPO interface that allows integration with building emergency shutoff systems or fire suppression controls. When triggered, EPO immediately cuts power to all connected loads — a requirement in many raised-floor data center and commercial facility codes.

Eden Phillips
Eden Phillips

The SURT15KRMXLI is one of the more capable single-phase online UPS units in its class — 12,000 W at 95% efficiency is the spec that jumps out to me. Most double-conversion units at this capacity run 92–93%, so that 2–3 point difference is real money over a 3–5 year deployment cycle in a 24/7 environment. If you're running a full server rack continuously, that efficiency delta can offset a meaningful fraction of the unit's capital cost.

Technical Highlights:

  • 95% Efficiency (Online Mode): At 15 kVA / 12 kW continuous, even a 2% efficiency improvement over a typical 93% competitor unit saves roughly 240 W of heat dissipation — that's less cooling load, less facility power draw, and lower operating cost every hour the unit runs.
  • 40–70 Hz Input Frequency Range: Most online UPS units accept 45–65 Hz. The SURT15KRMXLI's wider 40–70 Hz window is an explicit generator-compatibility spec — relevant for any installation where utility backup is a diesel or natural-gas generator that may not hold tight frequency regulation under variable load.
  • 3:1 Crest Factor Tolerance: High-inrush loads — laser printers, motor starters, large switching PSUs — demand peak current well above RMS draw. A 3:1 crest factor means the inverter can deliver three times the RMS current in short bursts without clipping, which prevents waveform distortion on the output bus that would otherwise show up as load resets or power supply damage over time.

Deployment Considerations:

  • The C19 outlet configuration assumes your downstream distribution layer uses C20 inlets — confirm this before finalizing your PDU selection. If your rack gear uses C13 inlets, you'll need C19-to-C13 adapter cords, which add a connection point and reduce the per-outlet current rating to 13 A (C13 spec).
  • At 50 dB(A) operating noise, this unit is unsuitable for open-plan office or light commercial spaces without acoustic separation. Plan for a dedicated equipment room or enclosed rack with adequate ventilation if the installation is near occupied areas.

The SURT15KRMXLI is the right fit for a high-density server rack room or colocation cage serving European or international 230 V single-phase distribution — particularly where generator backup is part of the power chain and you need a UPS that won't cycle to battery every time the generator drifts in frequency under load.

Specifications
UPS topology: Double-conversion (Online)
Output power capacity: 15 kVA
Output power: 12000 W
Waveform: Sine
Input frequency: 40 - 70 Hz
Output operation voltage (min: 220 V
Output operation voltage (max: 240 V
Output frequency regulation: 50/60 Hz
Maximum current: 90 A
Number of output phases: 1
Efficiency: 95%
Crest factor: 3:1
Emergency Power Off (EPO: Yes
Noise level: 50 dB
Surge protection: Yes
Audible alarm(s: Yes
Auto-restart: Yes
AC outlet types: C19 coupler
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources