Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C2SG36TE-4PAE2M66 22.0kW 3-Phase Switched Outlet-Metered Rack PDU
Overview
The Server Technology C2SG36TE-4PAE2M66 is a 3-phase, 400V input Smart POPS rack PDU built for data center racks that need outlet-level power data without guessing at load balance across phases. Rated for 22.0kW at a 32A input current, it feeds 36 total outlets — 24x C13 and 12x HDOT Cx — through a 32A IEC 60309 3P+N+PE 6Hr plug. This is a PRO2 HDOT platform unit, meaning every outlet reports individually through POPS (Per-Outlet Power Sensing), and the whole unit reports inlet-level draw through PIPS (Per-Inlet Power Sensing). For colocation and hyperscale racks running mixed C14/C20 loads off one strip, the C2SG36TE-4PAE2M66 removes the need to guess which outlet is overloaded during a capacity review.
Key Features
- HDOT Cx Hybrid Outlets (12x): Cx outlets are UL-tested to accept both C14 and C20 plugs on the same receptacle, so a rack with mixed 10A and 16A device cords doesn't need two different PDU models — one strip handles both.
- 24x C13 Outlets rated <=10A @230V L-N: Standard density for servers, switches, and network gear pulling sub-10A loads — the bulk of typical rack hardware.
- Per-Outlet Power Sensing (POPS): Reports current (A), voltage (V), power (W), apparent power (VA), crest factor, power factor, and energy at every individual outlet — useful when billing colocation tenants by actual draw rather than circuit allocation.
- Per-Inlet Power Sensing (PIPS): Same measurement set at the inlet level, so you can catch a developing overload at the circuit before it cascades to a tripped breaker.
- Branch Circuit Monitoring with 2-pole 20A Breakers: Each branch is monitored independently with SNMP alerting on high usage — you get a warning before a breaker trips, not a post-mortem after a rack goes dark.
- Branch Circuit Protection (UL 489 / UL 248): Meets UL and IEC 62368-1 branch protection requirements via magnetic-hydraulic breakers, satisfying code requirements integrators are held to on data center builds.
- Hot-Swap Network Card with Star Multi-Linking: Links up to four power circuits under one IP address, and if the Primary unit loses power, the Linked unit keeps network access alive — you don't lose remote visibility into the rest of the chain during a partial outage.
- Temperature/Humidity Monitoring (2x 4P4C inputs): Accepts two external 10ft probes with SNMP alerts and email notification — worth wiring into hot-aisle/cold-aisle monitoring rather than relying on room-level sensors alone.
- Auto-Flip Current Display: LED readout cycles per-phase current automatically, so a technician doing a visual load check on a three-phase unit doesn't need a laptop to spot an unbalanced phase.
- 1% Measurement Accuracy (Voltage/Current, Input and Output): Input and output measurement accuracy both hold to +/-1% (branch-level accuracy is +/-3%), tight enough for capacity planning models that assume metered PDU data is trustworthy.
- 10/100/1000 Mbps Ethernet + RS-232 Serial: Gigabit management plus a serial fallback path, with HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, and LDAP(S) all supported — fits into environments standardizing on LDAP-based access control for infrastructure devices.
- Operating Range 0°C to 60°C, 6,500ft Elevation: The extended thermal range and altitude rating support edge and telecom sites as well as standard data center floors, not just climate-controlled white space.
Integration & Compatibility
The C2SG36TE-4PAE2M66 (often searched as C2SG36TE 4PAE2M66) is part of the Server Technology PDU catalog, specifically the PRO2 HDOT line built for 11.0kW-22.0kW / 36-42 outlet configurations. It fits alongside other rack-mounted infrastructure in data center and colocation deployments where per-outlet billing or capacity accountability matters. Network management runs over standard protocols (SNMP, SSH, HTTP(S)) so it integrates into existing DCIM tooling without a proprietary agent. For planning rack power budgets alongside networking gear, see the PoE and power planning guide — while this unit isn't a PoE injector, the same load-balancing logic applies to three-phase branch circuit planning. Pair it with rack mounting accessories appropriate for a 70in vertical strip, and consult the data center infrastructure category for compatible monitoring and cooling gear.
Frequently Asked Questions
Q: What's the total outlet count on the C2SG36TE-4PAE2M66?
A: 36 outlets total — 24x C13 (rated <=10A @230V L-N) and 12x HDOT Cx hybrid outlets (rated <=16A @230V L-N) that accept both C14 and C20 plugs.
Q: What input power does this PDU require?
A: 400V 3-phase input at 32A rated current, terminating in a 32A IEC 60309 3P+N+PE 6Hr plug, for a total capacity of 22.0kW.
Q: Does the C2SG36TE-4PAE2M66 support per-outlet power monitoring?
A: Yes. It includes POPS (Per-Outlet Power Sensing), reporting current, voltage, power, apparent power, crest factor, power factor, and energy at each individual outlet, plus PIPS (Per-Inlet Power Sensing) at the inlet level.
Q: What network protocols does the management card support?
A: HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, and LDAP(S), over a 10/100/1000 Mbps Ethernet interface, with an RS-232 serial port as a secondary access path.
Q: What's the operating temperature range?
A: 0°C to 60°C with 8%RH to 90%RH non-condensing humidity, rated to 6,500ft elevation — suited to both standard data center floors and less climate-controlled edge sites.
Q: Can I link multiple C2SG36TE-4PAE2M66 units under one IP address?
A: Yes. Star Multi-Linking allows up to four power circuits to be linked under a single IP address, with the Primary unit's Expansion PDU providing backup power to the network card if the Primary loses power.

What gets my attention on the C2SG36TE-4PAE2M66 is the outlet mix: 24x C13 plus 12x HDOT Cx hybrid outlets on one 36-outlet strip. That Cx outlet accepting both C14 and C20 plugs means you're not stuck ordering a second PDU variant when a rack has a couple of higher-draw devices mixed in with standard servers.
Technical Highlights:
- 22.0kW at 400V / 32A 3-phase input: That's enough headroom for a dense rack running mixed compute and network gear without derating concerns at typical data center loads.
- POPS + PIPS dual-level metering at +/-1% accuracy: You get outlet-level and inlet-level readings both accurate to within 1%, which is tight enough to trust for tenant billing or capacity models — branch-level accuracy runs +/-3%, still fine for overload alerting.
- 2-pole 20A branch breakers with SNMP alerting: Branch circuit monitoring flags high usage before a breaker trips, which beats finding out about an overload when the rack goes dark.
Deployment Considerations:
- The 70in height means this is a full vertical zero-U strip — plan cable management and rack depth clearance before ordering, especially in high-density cabinets with already-tight PDU-to-rail spacing.
- Branch interrupt rating is 10kAIC in North America but drops to 5kAIC rest-of-world — confirm which rating applies before speccing it against local electrical code if this is going outside North America.
This is the right call for a colocation cage or hyperscale row where you need per-tenant or per-rack billing data down to the outlet, and where a mixed C13/C20 device population means a single fixed-outlet-type PDU won't cover the rack without a second unit.
Compare with similar
Server Technology Smart Pops - C2SG36TE-4PAE2M66
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology