Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Server Technology C2SG36TE-EQAF2M66 Switched Metered-by-Outlet Rack PDU
Overview
The Server Technology C2SG36TE-EQAF2M66 is a vertical 0U rack power distribution unit built for data center and network operations center racks that need outlet-level control and monitoring rather than a dumb power strip behind the rails. It runs on a 230V, 50/60 Hz input rated at 63A (48A rated current) through an IEC 230V/63A 2P+PE 6Hr plug, feeding an 11 kW capacity across 36 total outlets — 24x IEC 60320/C13 rated up to 10A at 230V L-N and 12x Cx outlets rated up to 16A at 230V L-N. At 70 inches tall, 2.2 inches wide, and 2.5 inches deep, it mounts in the vertical 0U rail space common to full-height cabinets, keeping horizontal U space open for servers, switches, and patch panels.
Key Features
- 36-outlet mixed C13/Cx layout: 24 C13 outlets plus 12 higher-capacity Cx outlets on a single strip means mixed-load racks — 1U servers on C13 whips alongside higher-draw switches or blade chassis on Cx — don't need a second PDU.
- 11 kW input capacity at 63A/230V: enough headroom for a densely populated rack without derating individual outlets, so you size the circuit once and don't revisit it as gear gets added.
- Branch circuit breakers at ≤16A with 10 kAIC (North America) / 5 kAIC (ROW) interrupt rating: a fault on one outlet branch trips locally instead of taking down the whole strip, and the interrupt rating means the breaker survives a real fault current instead of welding shut.
- Per-outlet and per-branch measurement accuracy (±1% voltage/power, ±3% branch current): C2SG36TE-EQAF2M66 reports outlet-level draw accurate enough to trust for capacity planning and chargeback, not just a rough estimate.
- Quiescent unloaded draw under 10W: the PDU's own overhead barely registers against an 11 kW budget, so your capacity math is about the load, not the metering hardware.
- Gigabit management port (10/100/1000 Mbps) plus RS-232 serial: network management for day-to-day monitoring, with a local serial console as a fallback path if the network segment is down during commissioning or a network outage.
- Encrypted management protocol set — HTTPS, TLSv1.2, SSHv2, SNMPv2c/v3, LDAPv3/LDAPS, TACACS+, RADIUS, SFTP: lets you fold the PDU into existing AAA infrastructure (RADIUS/TACACS+/LDAP) instead of managing local accounts on every unit, and drop Telnet/FTP in favor of the encrypted equivalents once commissioning is done.
- Dual temperature/humidity sensor inputs (4P4C): two independent probes let you monitor both the top and bottom of a hot rack, or intake and exhaust, from the same unit instead of running separate environmental monitoring.
- RJ-12 link port: daisy-chains additional PDUs or link-capable devices back to a single management point, reducing the number of IP addresses and network drops you need to provision per rack.
- Operating range 0°C to 60°C (32°F to 140°F), 8-90% RH non-condensing, to 6,500 ft elevation: the extended thermal ceiling covers hot-aisle conditions in poorly-conditioned or edge facilities where ambient can run well above a typical 40°C data hall spec.
- Storage range -30°C to 80°C (-22°F to 176°F), to 50,000 ft: gives logistics and staging teams wide margin for warehousing or air freight before the unit is racked and powered.
Integration & Compatibility
The C2SG36TE-EQAF2M66's IPv4/IPv6 dual-stack support and standards-based protocol list (SNMPv2c/v3, HTTP/HTTPS) mean it drops into existing data center infrastructure management (DCIM) and network monitoring platforms without a proprietary agent. For facilities standardizing on centralized authentication, TACACS+, RADIUS, and LDAPv3/LDAPS support keep PDU login credentials under the same policy as switches and consoles rather than a separate local user database. Pair it with rack-mounted NVRs or edge servers where outlet-level power cycling of hung devices avoids a truck roll, and review a PoE and power planning guide before finalizing circuit allocation across a multi-rack deployment. For the broader lineup, the Server Technology catalog includes lower-outlet-count and single-phase variants for smaller cabinets, and the network video recorder and PoE switch categories are common companions in the same racks this PDU powers.
Frequently Asked Questions
Q: What input voltage and plug does the C2SG36TE-EQAF2M66 require?
A: It requires a 230V, 50/60 Hz supply terminated in an IEC 230V/63A 2P+PE 6Hr plug, rated for 63A input current (48A rated).
Q: How many outlets does the C2SG36TE-EQAF2M66 have and what are they rated for?
A: It has 36 total outlets: 24x IEC 60320/C13 rated up to 10A at 230V L-N, and 12x Cx outlets rated up to 16A at 230V L-N.
Q: Does the C2SG36TE-EQAF2M66 provide per-outlet power monitoring?
A: Yes. It measures output current, voltage, active power, apparent power, power factor, crest factor, and energy at ±1% to ±3% accuracy depending on the metric, plus branch-level current at ±3%.
Q: What management protocols does the C2SG36TE-EQAF2M66 support?
A: HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c/v3, IPv4/IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, and FTP/SFTP, along with a Gigabit Ethernet port and an RS-232 serial console.
Q: What's the operating temperature range for the C2SG36TE-EQAF2M66?
A: 0°C to 60°C (32°F to 140°F) at 8-90% RH non-condensing, up to 6,500 ft elevation.
Q: What are the physical dimensions of the C2SG36TE-EQAF2M66?
A: 70 inches tall, 2.2 inches wide, and 2.5 inches deep — sized for vertical 0U mounting in a full-height rack.

What stands out on the C2SG36TE-EQAF2M66 is the outlet mix — 24 C13 plus 12 Cx across 36 total positions on an 11 kW, 63A/230V feed. That's a strip built for a rack that isn't uniform, which is most of them once you've got a mix of 1U servers and higher-draw network gear.
Technical Highlights:
- 63A input at 48A rated current: gives you real headroom below the breaker trip point, so transient inrush from switching gear on doesn't nuisance-trip the branch.
- Branch breakers ≤16A at 10 kAIC (NA) / 5 kAIC (ROW): a short on one Cx outlet takes down that branch only, not the 35 other outlets on the strip.
- ±1% voltage/power and ±3% branch current accuracy: good enough to use for actual capacity planning and billback, not just a rough gauge on the front panel.
Deployment Considerations:
- At 70 inches tall and 2.2 inches wide, this is a 0U vertical mount — confirm your cabinet's rear channel depth clears the 2.5-inch body plus cable bend radius before ordering.
- The quiescent draw under 10W is negligible against 11 kW, but remember the 230V input means this unit is not a drop-in for a 120V North American circuit — verify your PDU whip and receptacle match the IEC 230V/63A 2P+PE plug before it ships to site.
This is the right strip for a European or international 230V data hall row with mixed C13/high-draw equipment, where per-outlet metering and RADIUS/TACACS+ integration matter as much as raw outlet count — not a fit for a 120V North American cabinet without a different input variant.
Compare with similar
Server Technology Smart Pops Master PRO2 - C2SG36TE-EQAF2M66
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Server Technology products? Shop the full Server Technology catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology