Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: FR9TP77B001M001
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 35% OFF

Panduit FR9TP77B001M001 12-Fiber Singlemode MPO Trunk

Panduit FR9TP77B001M001 Opti-Core 12-Fiber Singlemode MPO Trunk Cable The Panduit FR9TP77B001M001 is a factory-terminated 12-fiber OS2 singlemode MPO …

$581.66 $376.99 SAVE $205

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit FR9TP77B001M001 12-Fiber Singlemode MPO Trunk

$581.66
$376.99

Overview

SKU: FR9TP77B001M001
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FR9TP77B001M001 Opti-Core 12-Fiber Singlemode MPO Trunk Cable

The Panduit FR9TP77B001M001 is a factory-terminated 12-fiber OS2 singlemode MPO trunk cable engineered for rapid, reliable fiber deployment in data centers, telecommunications rooms, and high-density structured cabling environments. This 1-meter plenum-rated interconnect delivers the precision and performance demanded by 40/100G Ethernet migrations, storage networks, and backbone infrastructure—eliminating field termination labor while ensuring insertion loss consistency that hand-terminated assemblies can't match. Built on Panduit's Opti-Core platform with TIA-568.3-D compliance, this trunk cable bridges patch panels, switches, and enclosures where pre-tested, code-compliant fiber is non-negotiable.

Key Features

  • Factory-terminated MPO female connectors on both ends—zero field termination, consistent sub-0.5 dB insertion loss across all 12 fibers
  • OS2 singlemode fiber (9/125µm) supports 10G/40G/100G Ethernet up to 10 km, future-proof for coherent optics and high-speed migrations
  • OFNP plenum rating meets NEC Article 770 for installation in air-handling spaces without conduit—critical for drop-ceiling data center hot aisles and telecom room pathways
  • 1-meter (3.3 ft) length optimized for rack-to-rack, panel-to-switch, and cross-connect jumpers in structured cabling zones
  • TIA-568.3-D and ISO/IEC 11801 compliance ensures interoperability with enterprise fiber infrastructure and simplifies acceptance testing
  • MPO interface compatibility with breakout modules enables migration from 12-fiber trunks to individual LC duplex connections as needed
  • Opti-Core quality—Panduit's premium fiber line with batch testing, serialized documentation, and geometric performance guarantees
  • Low-profile MPO footprint maximizes panel density in 1U fiber enclosures and high-density switch front panels

Singlemode OS2 fiber operates at 9/125µm core/cladding diameter with a 1310 nm and 1550 nm wavelength window, enabling long-haul transmission that multimode OM3/OM4 cannot achieve. At 1 meter, this cable's primary value isn't distance—it's precision. Factory termination ensures every fiber in the 12-count ribbon meets geometric tolerances for core concentricity, ferrule endface geometry, and polish quality that field techs cannot replicate without clean-room conditions and interferometric inspection. The result: predictable 0.35 dB typical insertion loss per mated pair, critical when link budgets are tight in 100GBASE-LR4 or dense wavelength division multiplexing (DWDM) deployments. The MPO connector uses a push-pull latch and multi-fiber ferrule with guide pins (this assembly uses female pin-less connectors, requiring a mating male pinned MPO), allowing 12 fibers to mate in a single insertion—reducing patch panel real estate by 85% compared to twelve individual LC duplex connectors.

Deploy this trunk between high-density fiber enclosures and spine switches in leaf-spine data center fabrics, or as zone cabling interconnects in telecommunications rooms serving multiple equipment racks. The 1-meter length suits cross-connects where slack management is constrained—think top-of-rack to middle-of-rack patch panels, or horizontal cable management to vertical fiber managers. Plenum rating (OFNP per UL 910) is mandatory for cables installed above suspended ceilings in return-air plenums; non-plenum cable in these spaces fails code and triggers costly rework during inspections. Because this cable is pre-terminated and tested, installation time drops from 45 minutes per 12-fiber trunk (field termination, cleaning, testing) to under 3 minutes (route, plug, verify link light). That labor delta scales fast in 500+ port data center builds. Pair with Panduit MPO cassettes or breakout modules to fan out to LC duplex for 10GBASE-LR server connections, or maintain MPO-to-MPO throughout the trunk layer for 40GBASE-SR4 or 100GBASE-SR10 parallel optics.

TIA-568.3-D and ISO/IEC 11801 compliance means this cable meets enterprise structured cabling standards for generic cabling systems, ensuring it integrates into mixed-vendor environments without compatibility risks. ITU-T G.652.D conformance confirms the fiber itself matches the international standard for singlemode optical fiber, critical for carrier-grade and long-term network planning. Panduit Opti-Core assemblies ship with serialized test reports documenting insertion loss, return loss, and length per fiber—acceptance testing artifacts that satisfy IT governance and warranty requirements without re-testing every link. The cable jacket uses low-smoke materials and meets flame propagation limits under NFPA 262 (UL 910 equivalent), required for life-safety code compliance in occupied buildings.

Choose the Panduit FR9TP77B001M001 when installation speed, code compliance, and performance consistency are non-negotiable. This is the cable for integrators and datacenter operators who refuse to gamble on field termination quality in high-stakes fiber backbones—where a single bad fiber in a 12-count trunk can choke a 100G uplink and cost hours of troubleshooting. Factory precision, plenum compliance, and Opti-Core quality make this a go-to trunk for professional infrastructure builds.

Eden Phillips - Networking & Infrastructure Specialist
Senior Specialist
Eden Phillips
Networking, PoE Switches & Infrastructure
Specifications
Product Type: Fiber Optic Trunk Cable
Manufacturer Part Number: FR9TP77B001M001
Sub-Brand: Opti-Core
Fiber Type: OS2 Singlemode 9/125µm
Number of Fibers: 12
Connector Type: MPO Female (both ends)
Cable Length: 1.0 m (3.3 ft)
Flammability Rating: Plenum (OFNP)
Standards Compliance: TIA-568.3-D, ISO/IEC 11801, ITU-T G.652.D
Application: Data centers, telecommunications rooms, entrance facilities, equipment distribution areas
Wavelength: 1310 nm / 1550 nm
Insertion Loss:
Jacket Material: Low-smoke plenum-rated
Polish Type: Factory-terminated precision polish
Pin Configuration: Female (pin-less)
Type: Cable
Connectivity: Fiber Optic
Cable Category: fiber_optic
Fiber Count: 12
Length Ft: 3.3
Length M: 1.0
Standards: TIA-568.3-D, ISO/IEC 11801, ITU-T G.652.D
Sub Brand: Opti-Core®
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources