Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: FR9TP77B001F001
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 31% OFF

Panduit FR9TP77B001F001 12-Fiber MPO Plenum Trunk Cable

Panduit FR9TP77B001F001 12-Fiber Singlemode MPO Plenum Trunk Cable The Panduit FR9TP77B001F001 is a 1-foot, 12-fiber singlemode trunk cable designed f…

$578.10 $399.99 SAVE $178

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit FR9TP77B001F001 12-Fiber MPO Plenum Trunk Cable

$578.10
$399.99

Overview

SKU: FR9TP77B001F001
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FR9TP77B001F001 12-Fiber Singlemode MPO Plenum Trunk Cable

The Panduit FR9TP77B001F001 is a 1-foot, 12-fiber singlemode trunk cable designed for high-density fiber deployments in data centers, telecommunications rooms, and enterprise network cores. Featuring factory-terminated MPO female connectors on both ends, this plenum-rated (OFNP) trunk eliminates field termination labor while delivering guaranteed insertion loss performance straight out of the package. Built on OS2 9/125µm singlemode fiber, it supports 40GBASE-SR4, 100GBASE-SR10, and future 400G applications across structured cabling backbones where speed, reliability, and installation efficiency matter.

Key Features

  • Factory Pre-Terminated MPO Connectors: Both ends ship with precision-polished MPO female connectors, eliminating the cost, time, and variability of field terminations—critical when deploying dozens or hundreds of trunk links under tight project timelines.
  • Plenum-Rated OFNP Jacket: Meets NEC Article 770 requirements for installation in air-handling spaces without conduit, simplifying compliance in ceiling plenums, raised floors, and HVAC pathways common to modern data centers.
  • OS2 Singlemode 9/125µm Fiber: Engineered for low attenuation and wide bandwidth across C-band and L-band wavelengths, supporting 10G, 40G, 100G, and emerging 400G Ethernet standards over distances from 1 meter to 10+ kilometers depending on transceiver optics.
  • Type B Polarity, Standard IL: Ships with Type B (straight-through) polarity and standard insertion loss grade, integrating seamlessly into TIA-568.3-D and ISO/IEC 11801-compliant structured cabling systems without adapter complexity.
  • High-Density 12-Fiber Configuration: Delivers six duplex channels in a single compact trunk, ideal for 40GBASE-SR4 breakout applications or as a cost-effective backbone segment in modular cassette-based distribution architectures.
  • Panduit Opti-Core® System Component: Part of Panduit's end-to-end pre-terminated fiber platform, ensuring mechanical and optical compatibility with Opti-Core® cassettes, panels, and enclosures across the entire physical layer.
  • 1-Foot Length for Rack-to-Rack or Panel Interconnects: Short enough to minimize cable management challenges in dense equipment rows, yet long enough to provide service loop and strain relief when connecting adjacent patch panels, zone distribution enclosures, or top-of-rack switches.
  • Factory Tested and Certified: Every trunk undergoes end-to-end insertion loss and return loss testing before shipping, with test results available upon request—eliminating the risk of bad fibers discovered only after installation.

The FR9TP77B001F001 addresses the central challenge of modern data center and telecom infrastructure: delivering Tier 1 optical performance at Tier 2 deployment speed. Field termination of singlemode MPO connectors demands specialized training, expensive tooling, and rigorous inspection—each adding days to project schedules and introducing points of failure. This trunk cable shifts that termination process to Panduit's controlled manufacturing environment, where automated polishing, interferometric inspection, and statistical process control ensure every connector meets TIA-568.3-D Category OS2 specifications for insertion loss (≤0.75 dB typical) and return loss (≥50 dB typical). For network engineers managing 40G spine-leaf fabrics, 100G DCI links, or staged migrations to 400G, that factory assurance translates directly to predictable link budgets, faster troubleshooting, and fewer truck rolls.

The plenum-rated (OFNP) jacket compound is engineered for low smoke and flame propagation per UL 910 and NFPA 262, making the cable code-compliant for installation in return-air plenums, suspended ceilings, and under raised floors without the expense and space penalty of conduit or cable tray. In retrofit environments where existing pathways are congested, the small bend radius and flexible jacket of this 12-fiber trunk enable routing through tight corners and narrow cable trays that would reject rigid armored assemblies. The 1-foot length is particularly valuable in high-density MDA (main distribution area) and HDA (horizontal distribution area) deployments, where dozens of trunks interconnect cassette modules, breakout panels, and switch uplinks within a single 42U rack or adjacent equipment row. Unlike 3-meter or 5-meter trunks that create service-loop management headaches, this short jumper keeps the optical path clean, the cable management legible, and the airflow unobstructed—essential when rack power densities exceed 10 kW and every cubic inch of obstructed airflow costs cooling capacity.

The 12-fiber count maps cleanly to the dominant use cases in contemporary structured cabling: breakout to six LC duplex channels for 10GBASE-LR uplinks, native 40GBASE-SR4 using parallel optics across four lanes, or a single 100GBASE-SR10 link when paired with 24-fiber MPO breakout cassettes. Type B polarity (straight-through key-up to key-up) simplifies integration into TIA-568.3-D Method B architectures, which remain the most widely deployed polarity scheme in North American enterprise and hyperscale data centers. Standard insertion loss grade ensures compatibility with IEEE 802.3 link budgets for 40G and 100G Ethernet without requiring premium (low-loss) transceivers, keeping optics costs in check. For installations planning a future migration to 400GBASE-DR4 or 400GBASE-FR4, the OS2 fiber's intrinsic bandwidth and attenuation characteristics provide headroom for PAM4 modulation and DWDM overlays, protecting the physical layer investment as speeds scale.

This trunk cable is qualified to TIA-568.3-D, ISO/IEC 11801, and ITU-T G.652.D standards, ensuring interoperability with transceivers, cassettes, and test equipment from any standards-compliant vendor. The Panduit Opti-Core® system architecture—of which this trunk is a component—ships as a cohesive ecosystem where trunks, cassettes, panels, and enclosures share common mechanical interfaces, polarity schemes, and port densities, reducing the risk of mismatched keying, incorrect polarity, or incompatible port counts that plague mixed-vendor fiber deployments. For network operators managing multi-building campuses, co-location facilities, or staged data center expansions, that vendor-neutral standards compliance combined with single-source system integration delivers the best of both worlds: competitive bidding on optics and active equipment, with a known-good physical layer that won't become the scapegoat when a new switch vendor's optics won't link up.

Eden Phillips
Eden Phillips
Senior Specialist - Network Infrastructure
Fiber backbone deployments succeed or fail on three factors: polarity discipline, loss budget accuracy, and installation speed. Pre-terminated MPO trunks like the FR9TP77B001F001 remove the single largest source of field failures—hand-terminated connectors—while cutting deployment time by 70% compared to fusion splicing or field-polish methods. For network teams managing 40G/100G spine fabrics or DCI links, this is the difference between a two-day maintenance window and a two-week project with unpredictable outcomes.
Specifications
Product Type: Fiber Optic Trunk Cable
Manufacturer Part Number: FR9TP77B001F001
Sub-Brand: Opti-Core®
Number of Fibers: 12
Fiber Type: OS2 Singlemode (9/125µm)
Connector Type A: MPO Female
Connector Type B: MPO Female
Polarity: Type B (Straight-Through)
Insertion Loss Grade: Standard
Cable Length: 1.0 ft (0.3 m)
Jacket Rating: Plenum (OFNP)
Flammability Standard: UL 910, NFPA 262
Application: Data centers, telecommunications rooms, entrance facilities, equipment distribution areas
Standards Compliance: TIA-568.3-D, ISO/IEC 11801, ITU-T G.652.D
Supported Data Rates: 10G, 40G, 100G, 400G Ethernet
Temperature Range: -20°C to +70°C
Package Quantity: 1
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources