Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv VP5N41A0 is a switched, three-phase horizontal rack PDU rated at 35A and 208V delta, delivering up to 10.0kW of managed power across 12 outlets in a 0U horizontal footprint. It's built for data center racks and colocation environments where administrators need remote outlet-level control — the ability to sequence power, hard-reboot hung servers, and cut individual circuits without touching the rack. If your ops team needs to manage power from a NOC or across a distributed campus, this is the class of PDU that makes that possible.
The VP5N41A0 ships with a 3-meter input cord, an LED display for at-a-glance load monitoring, and a network stack broad enough to drop into virtually any enterprise environment without friction.
The VP5N41A0 integrates with rack PDU management platforms via SNMP v1/v2c/v3 — compatible with leading DCIM tools, NMS platforms, and BMS systems through Modbus TCP. LDAP, RADIUS, and TACACS+ authentication hooks align with enterprise AAA infrastructure. HTTP and HTTPS access supports browser-based management without a dedicated client application. The unit's RSTP support enables resilient network topologies where the management network itself has redundant paths. Pair this PDU with a compatible UPS from the Vertiv power management line for a fully monitored power chain from utility input to individual outlet. For high-density compute deployments, review the rack PDU selection guide to match inlet configuration and current rating to your panel's branch circuit capacity before ordering. Three-phase delta input at 208V requires a compatible three-phase panel or RPP — confirm your facility's wiring configuration against the VP5N41A0's inlet spec before installation.
Q: What input voltage and phase configuration does the VP5N41A0 require?
A: The VP5N41A0 requires a 208V delta three-phase input rated at 35A. It supports 50/60 Hz and is not compatible with single-phase panel feeds. Confirm your facility's branch circuit and panel configuration before installation.
Q: Can I switch individual outlets remotely on the VP5N41A0?
A: Yes. The VP5N41A0 is a switched PDU with outlet-level control across all 12 receptacles (C13 and C19 mix). Each outlet can be turned on, off, or sequenced independently via the network management interface.
Q: What network protocols does the VP5N41A0 support for management?
A: The VP5N41A0 supports SNMP v1/v2c/v3, HTTP, HTTPS, SSH, DHCP, NTP, SMTP, Syslog, LDAP, RADIUS, TACACS+, Modbus TCP, RSTP, and both IPv4 and IPv6.
Q: Does the VP5N41A0 support enterprise authentication (LDAP, RADIUS, TACACS+)?
A: Yes. All three enterprise AAA protocols — LDAP, RADIUS, and TACACS+ — are supported natively, allowing management access to be authenticated against your existing directory infrastructure.
Q: What does the VP5N41A0 monitor at the unit level?
A: The unit monitors current (amps), power (watts/kW), and voltage continuously. This data is accessible via SNMP, the web interface, and the front-panel LED display.
Q: What is the rack mounting orientation of the VP5N41A0?
A: The VP5N41A0 is a horizontal (0U footprint in standard horizontal orientation) mount PDU designed for installation in a standard 19-inch equipment rack.

The VP5N41A0 is a unit I'd spec without hesitation into a high-density colocation bay or a managed hosting rack where the ops team needs hard power-cycle capability without a hands-and-eyes dispatch. The 35A three-phase delta input at 208V means you're drawing balanced current across all three legs — that's what keeps your branch circuit breakers from nuisance-tripping in a dense compute environment, and 10.0kW of usable capacity covers a fully populated 42U rack of modern 1U/2U servers without headroom anxiety.
Technical Highlights:
Deployment Considerations:
The VP5N41A0 is the right call for managed colocation operators, enterprise data center teams, and hosting providers who need per-outlet control, DCIM-ready monitoring, and AAA-integrated security in a single horizontal PDU — and who are running a three-phase 208V delta infrastructure to support it.