Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv VP4N41A1 is a 0U horizontal, three-phase monitored rack PDU rated at 35A/208V delta and 10.0kW — built for dense data center and equipment room deployments where real-time power visibility at the unit level is a non-negotiable operational requirement. With six locking C19 outlets, a 3-meter input cord, and an onboard LCD display, the VP4N41A1 gives power and facilities engineers the instrumentation they need without adding rack-unit overhead to already-tight enclosures.
This is a rack power distribution unit designed for environments running high-density servers, storage arrays, or network gear on three-phase 208V circuits. If your team manages uptime SLAs, the per-outlet locking mechanism and unit-level current/voltage/power monitoring directly reduce the two most common failure modes: accidental disconnects and undetected overloads.
The VP4N41A1's protocol breadth — SNMP v1/v2c/v3, Modbus TCP, HTTP/HTTPS — positions it for integration with leading data center infrastructure management platforms and BMS systems. SNMP v3 traps can feed directly into monitoring stacks like Nagios, Zabbix, SolarWinds, or any DCIM tool with an SNMP receiver. Modbus TCP extends compatibility to building automation controllers that don't support SNMP. LDAP, RADIUS, and TACACS+ authentication support means user access can be centrally managed through existing directory services — no local account sprawl.
If you're planning a monitored Vertiv power distribution deployment across multiple racks, the RSTP support enables loop-free network topologies when daisy-chaining management connections, and IPv6 readiness future-proofs the management plane as networks migrate away from IPv4. For SMTP alerting, the PDU can send threshold-breach notifications directly to operations email or ticketing system webhooks — removing the dependency on a polling-only DCIM setup.
Pair this unit with appropriate PDU mounting hardware and cable management accessories to complete the horizontal installation in open-frame or enclosed racks.
Q: What outlet type does the VP4N41A1 use, and why does it matter?
A: The VP4N41A1 uses six C19 locking outlets. C19 is the correct connector for server and network equipment PSUs rated above 10A, and the locking mechanism prevents accidental disconnects — a common cause of unplanned downtime in dense rack environments.
Q: What monitoring parameters does the VP4N41A1 measure?
A: The VP4N41A1 monitors current, voltage, and power at the unit level. This gives operators a real-time view of rack load without a separate power meter, and enables capacity planning before adding new equipment.
Q: Does the VP4N41A1 support SNMP v3?
A: Yes. The VP4N41A1 supports SNMP v1, v2c, and v3, along with SSH, HTTPS, LDAP, RADIUS, TACACS+, Syslog, SMTP, NTP, Modbus TCP, RSTP, IPv4, and IPv6 — a full enterprise management protocol stack.
Q: What is the maximum current and power rating of the VP4N41A1?
A: The VP4N41A1 is rated at 35A maximum current and 10.0kW load capacity on a 208V delta three-phase input. The input voltage range is 200–240V AC at 50 or 60 Hz.
Q: How does the VP4N41A1 mount in a rack?
A: The VP4N41A1 is a 0U horizontal unit, meaning it mounts to the rack frame without consuming any rack units. It ships with a 3-meter input cord, which reaches standard floor PDU strips or overhead busway in most raised-floor data center configurations.
Q: Can the VP4N41A1 integrate with DCIM or BMS platforms?
A: Yes. SNMP v3 is compatible with most DCIM and network monitoring platforms (Nagios, Zabbix, SolarWinds, etc.). Modbus TCP extends integration to building management systems and BAS controllers that don't support SNMP. SMTP alerting enables direct notification to operations teams or ticketing systems on threshold breaches.

The VP4N41A1 is the unit I reach for when a client needs three-phase power monitoring in a horizontal 0U form factor without giving up rack space. The 35A/208V delta rating at 10.0kW means it's sized for real high-density loads — not the 6–8kW you see on lighter-duty units that run out of headroom when the rack fills up.
Technical Highlights:
Deployment Considerations:
The VP4N41A1 is the correct specification for colocation operators, enterprise data center teams, and edge deployments running high-density compute or storage racks on three-phase 208V infrastructure where unit-level power accountability and DCIM/BMS integration are non-negotiable requirements.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Vertiv products? Shop the full Vertiv catalog →