Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv VP5N30AP is a 0U vertical switched rack PDU designed for high-density data center and server room deployments where remote outlet-level control and real-time power monitoring are non-negotiable. Rated at 30A/208V (4.9kW), it delivers 24 mixed C13/C19 outlets on a NEMA L6-30P input — a format that fits directly into standard 3m power whips without adapters in most raised-floor and hot-aisle/cold-aisle cabinets. If you're managing colocation gear, network infrastructure, or rack power distribution at scale, the VP5N30AP gives you per-outlet switching and unit-level current, voltage, and power monitoring from a single device.
The vertical 0U form factor keeps all 42U of usable rack space intact. This matters in fully loaded cabinets where a 1U or 2U horizontal PDU would displace revenue-generating equipment. A built-in LCD display provides at-a-glance readings without requiring a network connection during initial commissioning or troubleshooting.
The VP5N30AP connects to managed network infrastructure via its dual RJ-45 ports and integrates with DCIM platforms, NMS tools, and SIEM systems through SNMP v1/v2c/v3 and Syslog. RADIUS and TACACS+ authentication align with enterprise AAA frameworks common in colocation and enterprise data centers. Modbus TCP support extends compatibility to building management systems (BMS) and industrial monitoring platforms that don't speak SNMP natively.
For organizations running Vertiv's Intelligent Infrastructure Management (IIM) suite or third-party DCIM tools, the VP5N30AP's standard SNMP MIB structure and dual-IP daisy chain topology are compatible with most row-level polling architectures. Verify MIB file availability and firmware version requirements with Vertiv's support documentation before deploying at scale.
Pair this unit with a compatible UPS upstream to complete a fully monitored and switched power distribution chain from UPS output to individual server inlet. For data center power planning, factor the 4.9kW maximum load and the L6-30P input requirement when sizing circuits and specifying upstream breaker panels.
Q: What is the maximum continuous load the VP5N30AP should carry?
A: The VP5N30AP is rated at 30A/208V (4.9kW maximum). Per standard data center practice, continuous loads should not exceed 80% of the breaker rating — 24A continuous in this case. Exceeding this threshold risks nuisance tripping of upstream breakers.
Q: Can I manage multiple VP5N30AP units from a single IP address?
A: Yes. The VP5N30AP supports daisy chaining via its dual RJ-45 Ethernet ports, allowing multiple units to be managed from a single network address. This reduces switch port consumption in dense row deployments.
Q: Does the VP5N30AP support SNMP v3?
A: Yes. The VP5N30AP supports SNMP v1, v2c, and v3, along with HTTPS, SSH, RADIUS, TACACS+, LDAP, Syslog, NTP, Modbus TCP, and both IPv4 and IPv6 — the full enterprise monitoring and authentication stack.
Q: What type of power plug does the VP5N30AP use?
A: The VP5N30AP uses a NEMA L6-30P input plug, which connects to standard 30A/208V locking receptacles common in North American data centers and colocation facilities.
Q: Does the VP5N30AP monitor power at the outlet level or only at the unit level?
A: The VP5N30AP provides unit-level monitoring of current, voltage, and power. Per-outlet switching is supported, but verify outlet-level metering capabilities against the current Vertiv datasheet if granular per-outlet power measurement is a requirement for your deployment.
Q: Can the VP5N30AP be mounted horizontally in a standard rack?
A: The VP5N30AP is designed for vertical 0U mounting in the side or rear channel of standard 4-post cabinets, preserving all rack unit space for active equipment. It is not intended for horizontal 1U/2U rack mounting.

The VP5N30AP is the unit I reach for when a client needs switched, monitored power distribution in a fully loaded cabinet and can't afford to sacrifice rack U-space to a horizontal PDU. The 0U vertical form factor combined with a 30A/208V NEMA L6-30P input and 24 mixed C13/C19 outlets covers the majority of enterprise server room and colocation deployments I encounter — and the dual-port daisy chain is what makes it practical to deploy at row scale without burning a switch port per PDU.
Technical Highlights:
Deployment Considerations:
The VP5N30AP is the right call for enterprise colocation buildouts, high-density server rooms, and managed service provider infrastructure where remote outlet control, enterprise authentication integration, and row-level daisy-chain management are requirements rather than nice-to-haves.