SKU: VP5N30AU
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv VP5N30AN is a 0U vertical rack PDU delivering switched, outlet-level power management at 30A/208V (4.9 kW) across 36 receptacles — the right unit when you need remote power cycling, granular load visibility, and protocol-rich integration in a dense rack without burning a rack unit on horizontal PDU real estate. The NEMA L6-30P input plug and 200–240 V single-phase design pair it directly with the stepped-down 208 V circuits found in most North American data center and IDF environments. The 3-meter cord gives you clean reach from floor-level whips or overhead busway without extension adapters in most standard 42U–48U cabinets.
The VP5N30AN integrates with any DCIM or building management system that can consume SNMP v1/v2c/v3 or Modbus TCP — including Vertiv's own Trellis platform, Schneider EcoStruxure, and third-party tools like PRTG, SolarWinds, or Nagios. HTTPS and SSH secure the management interface at rest and in transit. RADIUS, LDAP, and TACACS+ support means you're not managing a separate local credential store — tie it into your existing AAA infrastructure on day one. For environments running mixed IPv4/IPv6, dual-stack support avoids the need for translation or separate management segments. DHCP simplifies initial addressing in managed environments; static IP assignment is available for production. Check your rack power distribution requirements and review the full Vertiv PDU catalog for matched input cord, outlet count, and amperage variants before finalizing your order.
Q: What input plug does the VP5N30AN use, and what circuit does it require?
A: The VP5N30AN ships with a NEMA L6-30P input plug and requires a 30A/208V single-phase circuit. In most North American data centers, this maps directly to a standard 30A/208V dedicated branch circuit with an L6-30 receptacle.
Q: How many outlets does the VP5N30AN have, and what types are they?
A: The unit provides 36 AC outlets in a mix of C13 and C19 coupler types, with locking receptacles to prevent accidental cord disconnection. This covers both standard server power supplies (C13) and higher-draw devices (C19).
Q: Can I remotely power-cycle individual outlets on the VP5N30AN?
A: Yes. The VP5N30AN is a switched PDU with outlet-level control, allowing you to individually switch outlets on, off, or sequence their reboot via the network management interface — no physical access to the rack required.
Q: What network protocols does the VP5N30AN support for management integration?
A: The VP5N30AN supports SNMP v1/v2c/v3, HTTP, HTTPS, SSH, DHCP, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SMTP, Syslog, TACACS+, and Modbus TCP — providing broad compatibility with DCIM platforms, monitoring tools, and enterprise AAA infrastructure.
Q: Does the VP5N30AN support IPv6?
A: Yes, the VP5N30AN supports both IPv4 and IPv6 dual-stack, so it can be managed on either or both addressing schemes without additional translation hardware.
Q: What is the maximum power capacity of the VP5N30AN?
A: The VP5N30AN delivers up to 4.9 kW at 30A/208V single-phase. For safe continuous operation, plan loads at 80% of rated capacity — approximately 3.9 kW — in line with standard NEC branch circuit derate practice.

The VP5N30AN stands out in the switched PDU category specifically because of its protocol depth — SNMP v3 with LDAP/RADIUS/TACACS+ authentication isn't standard on every vertical PDU at this price tier, and it matters the moment you're managing more than a handful of racks. I spec this unit when the facility team requires rack-level power metering (current, voltage, and wattage all reported at the inlet) alongside IT's need for outlet-level cycling — you're getting both in a single 0U device.
Technical Highlights:
Deployment Considerations:
This is the right unit for a colocation customer or enterprise IT team managing mixed-density racks (servers + storage + networking) in a 208V environment where remote power cycling and DCIM-grade telemetry need to coexist on a single vertical PDU without consuming rack units.