Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The VP7N60A0 is a vertical 0U switched PDU engineered for high-density data center racks where per-outlet visibility and remote power cycling aren't optional — they're operational requirements. Drawing up to 60A at 200–240V three-phase (208V Delta), it delivers 17.2kW of usable capacity across 24 IEC C13 receptacles, fed via an IEC 60309 input plug. If you're managing dense server rows, colocation cages, or high-availability network equipment and need granular power accountability without dedicating rack U-space to the PDU, the VP7N60A0 is built for that job. Browse the full Vertiv power distribution lineup for the broader family context.
The VP7N60A0 fits into existing data center infrastructure management (DCIM) platforms via SNMP v1/v2c/v3 and Modbus TCP — two protocols with broad support across major DCIM vendors. HTTPS and SSH provide encrypted management sessions. The dual-Ethernet configuration supports both redundant uplinks and daisy-chain topologies, and the protocol suite (LDAP, RADIUS, TACACS+) integrates directly with enterprise AAA infrastructure. For environments already deploying network-managed PDUs, the VP7N60A0 fits within standard per-outlet metering and switching workflows. Pairing with a dedicated rack enclosure optimized for vertical PDU routing eliminates cable management complications. For planning your rack-level power budget, the rack power planning guide covers branch circuit sizing and PDU selection criteria in detail. See the broader data center power distribution category for complementary infrastructure.
Q: What input plug does the VP7N60A0 use and what circuit does it require?
A: The VP7N60A0 uses an IEC 60309 industrial input plug rated for 60A at 200–240V three-phase (208V Delta). Your branch circuit must be provisioned for 60A three-phase. The input cord is 3 meters long.
Q: Can I control individual outlets remotely on the VP7N60A0?
A: Yes — the VP7N60A0 is a switched outlet-level PDU. Each of the 24 IEC C13 outlets can be individually switched on, off, or power-cycled remotely via the network management interface. This is distinct from bank-level or inlet-level switching found on lower-tier PDUs.
Q: What monitoring parameters are available per outlet?
A: The VP7N60A0 monitors current, power, voltage, and temperature at the outlet level. This gives you per-device load accountability, not just total rack draw.
Q: Does the VP7N60A0 support enterprise authentication protocols like RADIUS or LDAP?
A: Yes. The VP7N60A0 supports LDAP, RADIUS, and TACACS+ for authentication, allowing PDU access control to integrate with your existing enterprise identity infrastructure. It also supports SNMP v3 for authenticated and encrypted SNMP management.
Q: How many PDUs can I daisy-chain together on a single network connection?
A: The VP7N60A0 supports daisy-chaining via its dual RJ-45 ports. Consult Vertiv's deployment documentation for the maximum supported chain length per firmware version, as this can vary with software updates.
Q: Does the VP7N60A0 take up rack unit space?
A: No — the VP7N60A0 is a 0U vertical PDU. It mounts in the rear channel of the rack and consumes no rack unit space, preserving the full equipment ladder for servers, switches, and other active gear.

The VP7N60A0 is the PDU I reach for when a customer has a 60A three-phase branch circuit feeding a high-density compute row and needs true per-outlet accountability — not just inlet metering dressed up as monitoring. The combination of outlet-level switching and current/power/voltage/temperature monitoring at each of the 24 C13 receptacles is what makes this unit operationally meaningful rather than just checkbox-compliant.
Technical Highlights:
Deployment Considerations:
For a colocation operator managing multi-tenant cabinets or a corporate data center running mixed compute with strict power accountability requirements, the VP7N60A0 provides the per-outlet granularity and enterprise authentication integration to support both operational efficiency and audit-readiness from a single 0U vertical unit.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Vertiv products? Shop the full Vertiv catalog →