Vertiv
SKU: VP7N30AS
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv VP7N30AJ is a 0U vertical rack PDU built for high-density three-phase deployments where granular power visibility matters at the individual outlet level. Rated at 30A / 17.2kW on a 200–240V / 346–415V WYE input, it delivers 48 C13 outlets in a vertical form factor that mounts inside the rack cabinet without consuming a single rack unit. If your data center, server room, or edge deployment demands per-outlet switching, real-time monitoring of current, power, voltage, and temperature, and a full enterprise protocol stack, this is the unit to evaluate. Explore the broader Vertiv power distribution lineup for complementary PDU families and accessories.
The VP7N30AJ's protocol breadth makes it compatible with most enterprise DCIM and monitoring platforms. SNMP v3 with authentication and encryption is the right choice for security-conscious environments — pair it with your existing NMS or DCIM tool via the three-phase PDU category for full environmental and power management integration. RADIUS, LDAP, and TACACS+ support means user authentication routes through your existing directory infrastructure rather than requiring local account management on each PDU. Modbus TCP extends compatibility to building management systems (BMS) and industrial monitoring platforms. For environments running IPv6-only or dual-stack networks, native IPv6 support means no NAT workarounds. See UPS and battery backup options for upstream power protection that pairs with this PDU, and consider rack enclosures compatible with vertical 0U mounting.
Q: What input plug does the VP7N30AJ use, and what circuit is required?
A: The VP7N30AJ uses a NEMA L22-30P plug, which requires a 30A three-phase WYE circuit operating at 200–240V or 346–415V. Confirm your facility's three-phase circuit type before ordering — a single-phase circuit will not work with this PDU.
Q: Does the VP7N30AJ support per-outlet power switching, or only monitoring?
A: It supports both. Each of the 48 C13 outlets can be individually switched on, off, or power-cycled remotely through the network management interface. This is a switched PDU, not a monitored-only unit.
Q: How many PDUs can be daisy-chained together on one IP address?
A: The VP7N30AJ supports daisy chaining via its dual RJ-45 Ethernet ports. Consult the Vertiv firmware documentation for the maximum chain length supported by the current firmware version, as this can vary by release.
Q: What authentication protocols are supported for user access?
A: The VP7N30AJ supports RADIUS, LDAP, and TACACS+ for centralized authentication, in addition to local accounts. SNMP v3 provides authenticated and encrypted SNMP access for monitoring integrations.
Q: What outlet type does this PDU provide?
A: All 48 outlets are IEC 60320 C13 couplers, suitable for standard C14 server and networking equipment power cords. This PDU does not include C19 outlets — verify your equipment's power cord requirements before deploying.
Q: Can this PDU be used in a horizontal rack mount configuration?
A: The VP7N30AJ is designed as a vertical 0U PDU for side-channel installation inside rack cabinets. It is not intended for horizontal rack-unit mounting.

The VP7N30AJ sits in a specific but important category: high-density three-phase PDUs where you need to do more than just distribute power. The 48 C13 switched outlets with per-outlet monitoring of current, power, and voltage is the spec that separates this unit from basic metered PDUs. If you're managing 40+ servers in a dense row and need to track per-device power consumption or remotely reboot a hung node, that granularity is not optional.
Technical Highlights:
Deployment Considerations:
The VP7N30AJ is best positioned in purpose-built colocation rows or enterprise data center aisles where per-server power accountability, remote outlet switching, and DCIM integration are operational requirements — not in small server closets or edge deployments where a single-phase metered PDU would be over-specified and simpler to manage.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Vertiv products? Shop the full Vertiv catalog →