Vertiv
SKU: VP6N30A8
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv VP6N30AM is a 0U vertical rack PDU engineered for high-density data center and colocation cabinets where per-outlet visibility isn't optional — it's the baseline for capacity planning, tenant billing, and proactive fault isolation. Running on a 30A, 208V Delta three-phase input via a NEMA L15-30P plug, this unit delivers 8.6kW of usable power across 36 C13 locking outlets while reporting current, voltage, power, and temperature in real time. For IT architects managing multi-tenant cabinets or warehouse automation engineers running dense compute loads, the VP6N30AM positions monitoring at the outlet level — the only granularity that catches a single runaway load before it trips a breaker and takes down a full rack.
Vertiv's Vertiv power distribution line anchors this unit in a proven commercial-grade PDU family. If you're evaluating rack power distribution units for a new cabinet build or refresh, the VP6N30AM sits at the managed end of the spectrum: full per-outlet telemetry, dual network ports, and enterprise authentication protocols baked in from the factory.
The VP6N30AM's PDU management protocol support is broad enough to integrate with virtually any enterprise NMS or DCIM platform. SNMP v1/v2c/v3 is the standard polling interface for platforms like SolarWinds, PRTG, Nagios, and Vertiv's own DCIM tools. Modbus TCP opens a direct path to building management systems and SCADA platforms without requiring a protocol converter. LDAP/RADIUS/TACACS+ integration means the PDU plugs into existing AAA infrastructure — no local user database to maintain across your PDU fleet.
For cabinet-level redundancy, the dual RJ-45 ports and daisy chain capability allow a single management VLAN connection to serve both the A-feed and B-feed PDUs in a dual-corded cabinet design. Pair this unit with a rack automatic transfer switch for full N+1 power path protection at the cabinet level. The nominal input voltage range of 200–240V accommodates standard North American three-phase distribution as well as international 50Hz environments where 208V or 220V delta feeds are common.
The vertical 0U mounting profile keeps all 42U or 48U of rack space available for revenue-generating compute, storage, or networking equipment — the correct choice whenever cabinet real estate is constrained and you're running high outlet density.
Q: What input plug does the VP6N30AM use, and what circuit does it require?
A: The VP6N30AM uses a NEMA L15-30P twist-lock plug, which requires a three-phase 30A, 208V Delta circuit. Verify your facility's panel configuration before ordering — L15-30P is a three-phase twist-lock, not a single-phase connector.
Q: How many outlets does the VP6N30AM have, and what type are they?
A: The unit provides 36 C13 locking outlets. The locking mechanism prevents accidental disconnection in dense cabinet environments.
Q: Can multiple VP6N30AM units share a single network connection?
A: Yes. The VP6N30AM supports daisy chaining via its dual RJ-45 Ethernet ports, allowing multiple PDUs to share a single network drop. This reduces switch port consumption in cabinets running both A-feed and B-feed PDUs.
Q: What monitoring parameters does the VP6N30AM measure per outlet?
A: The VP6N30AM monitors current, power, voltage, and temperature at the outlet level. This granularity supports load capacity planning, per-device chargeback reporting, and early detection of overload conditions before a breaker trip.
Q: Does the VP6N30AM support enterprise authentication protocols like LDAP or RADIUS?
A: Yes. The unit supports LDAP, RADIUS, and TACACS+ for integration with existing enterprise identity directories, eliminating the need to maintain local user accounts across a large PDU fleet.
Q: What is the total power capacity of the VP6N30AM?
A: The VP6N30AM delivers 8.6kW total at 30A, 208V Delta three-phase input. This is sufficient for fully-populated GPU compute nodes, blade chassis, or mixed high-density server and storage cabinets.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Vertiv products? Shop the full Vertiv catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price