Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: VP7N30AM
Condition: New
Write a Review 31% OFF

Vertiv Rpdu Switched Outlet Level Monitoring EC 30A 208V Delta 8.6KW Vertical (30 - VP7N30AM

Vertiv VP7N30AM Switched Outlet-Level Monitoring Rack PDUOverviewThe Vertiv VP7N30AM is a 0U vertical switched rack PDU delivering 30A at 208V Delta w…

$4,050.00 $2,777.99 SAVE $1272
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Vertiv Rpdu Switched Outlet Level Monitoring EC 30A 208V Delta 8.6KW Vertical (30 - VP7N30AM

$4,050.00
$2,777.99

Overview

SKU: VP7N30AM
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv VP7N30AM Switched Outlet-Level Monitoring Rack PDU

Overview

The Vertiv VP7N30AM is a 0U vertical switched rack PDU delivering 30A at 208V Delta with 8.6kW of capacity — purpose-built for data center and server room racks where you need granular power visibility and remote outlet control down to the individual device level. Part of the Vertiv PowerIT / Geist series, the VP7N30AM pairs outlet-level monitoring with remote switching, giving operations teams the ability to identify power hogs, reboot hung devices, and enforce load balance without physically touching the rack. If your current PDU is a blind power strip with no visibility below the breaker, this is the upgrade that closes that gap.

Key Features

  • Outlet-Level Power Monitoring: Power metering at every receptacle — not just at the input — means you can see exactly how much each connected device draws. That granularity matters when you're troubleshooting a runaway UPS load or proving capacity headroom before adding a new server.
  • 36 Locking Receptacles (30x C13, 6x C19): U-Lock locking IEC C13 and C19 connectors prevent accidental cord pulls — a real operational risk in high-density racks where cords bundle tight. The color-coded layout lets technicians quickly distinguish outlet groups without tracing cables.
  • Switched Outlets for Remote Reboot: Bi-stable latching relays let you power-cycle individual outlets from the network interface without sending someone to the data floor. The latching design holds its state through a controller reset, so a PDU reboot doesn't cascade into a rack-wide power cycle.
  • 8.6kW Input Capacity (NEMA L15-30P, 30A/208V Delta): 8,640W of headroom supports dense blade or GPU server deployments. The L15-30P input plug is standard for 30A three-phase panel connections — confirm your panel has an L15-30P breaker slot before ordering.
  • Dual Ethernet Ports: Two network ports enable daisy-chaining multiple PDUs on a single IP address, or primary/secondary network connections for resilience. Either way, you're not burning a switch port per PDU in a multi-unit rack.
  • Hot-Swappable IMD (Intelligent Metering Device): The metering controller can be replaced without powering down the PDU or the connected equipment — critical for maintaining uptime during firmware updates or hardware failures on the monitoring module.
  • 128x128 LCD Touchscreen: Local readout of input voltage, current, and per-outlet data without a laptop or remote session. Useful during initial commissioning and for quick spot-checks during physical audits.
  • Environmental Sensor Port: An onboard sensor port lets you attach temperature/humidity probes and fold environmental data into the same monitoring stream as power data — one agent instead of two.
  • 60°C Operating Temperature: Rated to operate in ambient temperatures up to 60°C, which covers hot-aisle containment environments that regularly push 45–55°C without margin concerns.
  • TAA-Compliant: Meets Trade Agreements Act requirements for federal procurement and government contractor deployments where domestic sourcing compliance is mandated.
  • 0U Vertical Form Factor: Mounts vertically in the zero-U space of a standard rack, preserving all 42U of usable rack unit space for active equipment — no rack space consumed by the PDU itself.

Integration & Compatibility

The VP7N30AM connects via dual Ethernet to standard data center management infrastructure. The environmental sensor port accepts compatible Vertiv PowerIT / Geist sensor probes for temperature and humidity integration. The NEMA L15-30P input requires a matching 30A, 208V three-phase circuit — verify panel and breaker compatibility before installation. TAA compliance and RoHS certification support both federal procurement workflows and international deployments requiring restricted-substance compliance. UL Listed and c-UL Listed (60950) certification confirms safety compliance for North American commercial and data center installations. FCC Part 15 Class A classification means this PDU meets radiated emissions limits for commercial environments.

Frequently Asked Questions

Q: Is the VP7N30AM TAA-compliant for federal government purchasing?

A: Yes. The VP7N30AM is TAA-compliant, making it eligible for federal procurement contracts and government contractor deployments that require Trade Agreements Act compliance.

Q: What input plug does the VP7N30AM use, and what circuit does it require?

A: The VP7N30AM uses a NEMA L15-30P input plug. It requires a dedicated 30A, 208V Delta three-phase circuit. Confirm your panel and branch circuit breaker are configured for L15-30P before installation.

Q: Can I replace the metering module without powering down connected equipment?

A: Yes. The VP7N30AM features a hot-swappable IMD (Intelligent Metering Device), allowing the monitoring controller to be replaced without interrupting power to connected devices.

Q: What is the warranty on the VP7N30AM?

A: The VP7N30AM carries a five-year limited manufacturer warranty.

Q: How many outlets does the VP7N30AM provide, and what locking connector types are used?

A: The VP7N30AM provides 36 total locking outlets: 30 IEC C13 and 6 IEC C19, all with U-Lock locking connectors to prevent accidental disconnection.

Q: Does the VP7N30AM support daisy-chaining multiple PDUs?

A: Yes. The dual Ethernet ports support daisy-chaining multiple PDUs, allowing several units to share a single IP address and reducing switch port consumption in multi-PDU rack configurations.

Karl Wilson
Karl Wilson

The VP7N30AM stands out in the Vertiv PowerIT line specifically because it brings outlet-level metering — not just input-level — to a 30A, 208V Delta vertical PDU. That distinction matters: input-only monitoring tells you the rack is drawing 22A total, but outlet-level monitoring tells you which device jumped from 2A to 6A at 2am and whether you have headroom for the GPU node being added next week.

Technical Highlights:

  • Bi-Stable Latching Relays: Switched outlets hold their last commanded state even if the PDU controller resets — no cascading power cycle on a controller fault, which is the failure mode that makes most ops teams distrust outlet switching in production racks.
  • 8,640W at 30A/208V Delta: Practical headroom for high-density compute or mixed server/storage racks. At 208V, you're pulling roughly 41.5A equivalent compared to 120V gear — factor that into your per-phase balance calculations at the panel.
  • Hot-Swap IMD: The monitoring controller can be replaced live. In practice, this means firmware updates or RMA replacements on the metering module don't require a maintenance window — a genuine operational advantage in 24/7 environments.

Deployment Considerations:

  • The NEMA L15-30P input is non-negotiable — this PDU will not connect to an L6-30P or L5-30P circuit. Verify your panel's three-phase 208V breaker and whip configuration before the unit arrives on the floor.
  • The environmental sensor port adds value, but probe compatibility is limited to the Vertiv PowerIT / Geist sensor ecosystem — confirm probe model compatibility with Vertiv before purchasing third-party sensors.

The VP7N30AM is the right call for colocation operators, enterprise IT teams managing high-density compute racks, and any deployment where per-device power accountability — not just aggregate load — drives capacity planning and chargeback reporting.

Specifications
Mount Type: Rack
Sub Brand: Vertiv PowerIT / Geist
Product Type: Rack PDU
Cable Category: Power Distribution
Input Voltage: 208V Delta
Output Voltage: 208V
Mounting: Rack (0U vertical)
Operating Temp: 60°C rated
Warranty: Five-year limited
Standards: UL Listed, c-UL Listed 60950, FCC Part 15 Class A, TAA-Compliant, RoHS certified
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources