Vertiv Rpdu Switched Outlet Level Monitoring 60A/63A 200-240V 14.4KW Vertical (36 - VP7U60A0

Vertiv VP7U60A0 Switched Outlet Level Monitored Rack PDUOverviewThe Vertiv VP7U60A0 is a 0U vertical switched rack PDU rated for 60/63A at 240V, deliv…

$4,952.00 $3,395.99 SAVE $1556
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Vertiv Rpdu Switched Outlet Level Monitoring 60A/63A 200-240V 14.4KW Vertical (36 - VP7U60A0

$4,952.00
$3,395.99

Overview

SKU: VP7U60A0
UPC: 767041047196
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv VP7U60A0 Switched Outlet Level Monitored Rack PDU

Overview

The Vertiv VP7U60A0 is a 0U vertical switched rack PDU rated for 60/63A at 240V, delivering up to 14.4kW of managed power across 36 combination C13/C19 outlets — the right unit when you need outlet-level visibility and remote switching in a dense rack deployment without sacrificing a rack unit. It connects via 1P+N+E (IP44) input plug and supports daisy-chaining up to 50 devices, making it a scalable backbone for data center rows and high-density compute racks. Its upgradeable architecture means the intelligence module can be swapped or upgraded without replacing the physical PDU, protecting the infrastructure investment as management requirements evolve. If you're evaluating Vertiv power distribution for your facility, the VP7U60A0 sits at the high end of the switched outlet monitored tier.

Key Features

  • 14.4kW / 15,120 VA Power Capacity: Supports full 60/63A draw at 240V — enough headroom for blade server chassis, GPU compute nodes, or high-density storage arrays without running close to breaker limits during peak load. Spec the PDU to 80% of breaker rating and this unit comfortably handles ~11.5kW continuous, leaving margin for inrush.
  • 36 Combination C13/C19 Outlets: Mixed outlet format means you can plug standard 1U servers (C13) alongside high-draw devices requiring C19 — without adapters or splitters. In practice, this eliminates the outlet-type bottleneck that forces premature PDU swaps when compute density increases.
  • Outlet-Level Monitoring and Switching: Every outlet can be individually monitored for load and remotely cycled — useful for hung servers, unresponsive network gear, or scheduled power sequencing. Outlet-level granularity means you're not cycling the whole PDU to restart one device, which matters in shared-rack environments.
  • Hot-Swappable IMD (Intelligence Module): The intelligence module can be removed and replaced while the PDU remains live and outlets stay powered. This is a significant operational advantage in production environments where a PDU reboot to service the management card is not acceptable.
  • Upgradeable Technology Architecture: The unit is designed to accept intelligence module upgrades without replacing PDU hardware. As network management or security requirements change — IPv6, enhanced SNMP, LDAP, certificate-based auth — you update the module, not the whole installation.
  • Daisy-Chain up to 50 Devices: A single network drop can manage up to 50 daisy-chained PDUs. For a row of racks in a colocation or enterprise data center, this reduces IP address consumption and simplifies DCIM integration — one management endpoint per row rather than one per rack.
  • P-Lock Cable Compatible Outlets: Vertiv's P-Lock retention system prevents accidental cable pull-outs on C13/C19 connections. In high-density racks where cables are packed tight, an inadvertent disconnect during patching work is a real operational risk — this feature mitigates it without requiring custom locking cables on every port.
  • TAA and RoHS Compliance: TAA compliance satisfies federal procurement requirements for US government contracts and GSA schedule purchases. RoHS and China RoHS compliance covers both domestic and export deployments where environmental material restrictions apply.
  • Network and Serial Connectivity: The unit supports both network interface and serial connection for management access, giving you fallback out-of-band access via serial console if the network management path is unavailable — a standard requirement for lights-out data center operations.

Integration and Compatibility

The VP7U60A0 is designed for integration into managed rack PDU environments with DCIM platforms via SNMP, Modbus, or the network management interface. Daisy-chain topology is a deliberate design choice for row-level DCIM deployments — a single upstream IP handles a run of up to 50 units, which simplifies both DCIM agent licensing and network switch port consumption. The combination C13/C19 outlet format aligns with standard data center power infrastructure cabling conventions, and P-Lock compatibility means you can enforce cable retention site-wide without sourcing proprietary PDU hardware. For facilities with mixed 60A/63A circuit standards — common in international deployments — the unit's dual 60/63A rating covers both without requiring separate SKUs. Pairing the VP7U60A0 with a compatible managed network switch for the daisy-chain uplink connection ensures management availability is not a single point of failure at the access layer.

Frequently Asked Questions

Q: What is the warranty on the Vertiv VP7U60A0?

A: The VP7U60A0 carries a 3-year standard manufacturer warranty. It is extendable to 5 years with product registration completed within 120 days of purchase.

Q: Is the VP7U60A0 TAA compliant?

A: Yes. The VP7U60A0 meets TAA (Trade Agreements Act) compliance requirements, making it eligible for US federal procurement and GSA schedule purchases.

Q: How many PDUs can be daisy-chained on the VP7U60A0?

A: Up to 50 devices can be daisy-chained, sharing a single network management connection. This reduces IP address and switch port consumption in row-level data center deployments.

Q: Can the intelligence module be replaced while the PDU is live?

A: Yes. The VP7U60A0 features a hot-swappable IMD (Intelligence Module Device), meaning the management module can be serviced or upgraded without powering down the outlets or interrupting connected equipment.

Q: What input plug type does the VP7U60A0 use?

A: The VP7U60A0 uses a 1P+N+E (IP44) input plug, rated for 60/63A at 240V. Verify your facility's circuit breaker and receptacle configuration matches before ordering.

Q: Does the VP7U60A0 support outlet-level power switching?

A: Yes. Each of the 36 combination C13/C19 outlets can be individually switched and monitored, enabling remote power cycling of individual devices without affecting other outlets on the same PDU.

Karl Wilson
Karl Wilson

The VP7U60A0's hot-swappable IMD is the spec I'd lead with for any enterprise data center evaluation — it means your management plane can be upgraded or serviced without a maintenance window that takes down 36 outlets and whatever is plugged into them. At 14.4kW across 60/63A input, this PDU is sized for high-density rows, and the daisy-chain ceiling of 50 devices means one IP can cover an entire data hall row without consuming switch ports or DCIM agent licenses at the per-PDU rate.

Technical Highlights:

  • 36 Combination C13/C19 Outlets: Mixed format eliminates outlet-type planning errors in dense deployments — no adapter chains, no mid-project PDU swap when a high-draw C19 device gets added to a mostly-C13 row.
  • Upgradeable Architecture: Replacing just the intelligence module rather than the full PDU hardware protects the capital investment when management software requirements change — a real cost differentiator in five-year facility plans.
  • P-Lock Cable Retention: In cable-dense racks, accidental disconnects during patching are a real incident vector. P-Lock outlets mitigate this without requiring every power cable in the facility to be swapped for locking variants.

Deployment Considerations:

  • The 1P+N+E (IP44) input plug is a European-style connector common in international data centers and some purpose-built US facilities — confirm your raised-floor circuit infrastructure matches before deploying at scale. This is not a NEMA L6-30 or L6-60 installation.
  • Daisy-chaining 50 units through a single network port simplifies IP management but also means a network path failure to that uplink PDU takes all 50 units offline for management — build redundant upstream paths if management continuity is a hard requirement.

The VP7U60A0 is the right specification for international colocation deployments, high-density GPU compute rows, or any enterprise data center facility running 240V IEC infrastructure where outlet-level remote cycling and live intelligence module serviceability are non-negotiable operational requirements.

Specifications
Mount Type: Rack
Product Type: Switched Rack PDU
Cable Category: Power Distribution
Input Voltage: 240V
Output Voltage: 240V
Mounting: Vertical Rack Mount
Dimensions: 3.5 in width
Weight: 19
Warranty: 3-year standard, extendable to 5-year with registration within 120 days
Standards: UL, RoHS, China RoHS, TAA
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources