Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv VP4N30AC is a rack-mounted, unit-level monitored power distribution unit built for three-phase 208V delta deployments in data centers and high-density server rooms. Rated at 30A input via NEMA L15-30P plug and delivering 8.6kW of distributed power across 24 locking IEC C13 outlets, this vertical PDU fits neatted into standard 0U rack space along the cabinet side rail — preserving every rack unit for compute or switching equipment. If your facility runs three-phase delta distribution and you need per-unit power visibility without committing to full outlet-level metering, the VP4N30AC hits that cost-versus-insight balance precisely.
The VP4N30AC's protocol breadth is its integration story. SNMP v3 polling feeds directly into platforms like SolarWinds, PRTG, Nagios, and most enterprise DCIM tools that speak standard MIBs. Modbus TCP opens integration with building management systems that may not speak SNMP. LDAP and RADIUS/TACACS+ mean user authentication follows your existing directory — no local account sprawl across dozens of PDUs. IPv6 readiness future-proofs the unit as data center networks migrate address space. The daisy-chain capability via dual RJ-45 is particularly relevant in power distribution deployments where you're managing multiple PDUs per cabinet — a single IP per rack pair cuts switch port requirements and simplifies DCIM discovery. For facilities running Vertiv's broader power and thermal catalog, the VP4N30AC fits the same management ecosystem as Vertiv's UPS and thermal monitoring products. Buyers evaluating rack PDU options should note the three-phase delta input requirement — this unit is not compatible with single-phase 120V or split-phase 208V circuits. Pair with a compatible managed network switch to enable the dual-port daisy chain and out-of-band management path.
Q: What input plug does the VP4N30AC use?
A: The VP4N30AC ships with a NEMA L15-30P input plug, rated for 30A three-phase 208V delta circuits. Verify your facility's receptacle type before ordering.
Q: Can I monitor individual outlet power consumption on the VP4N30AC?
A: No. The VP4N30AC provides unit-level monitoring of current, power, and voltage — not per-outlet metering. If outlet-level granularity is required, consider a switched or outlet-metered PDU in the Vertiv Geist family.
Q: Does the VP4N30AC support daisy chaining, and how does it work?
A: Yes. The dual RJ-45 Ethernet ports allow multiple VP4N30AC units to be daisy-chained, enabling a group of PDUs to share a single IP address and reducing the number of switch ports consumed per cabinet.
Q: What network protocols does the VP4N30AC support for DCIM integration?
A: The unit supports SNMP v1/v2c/v3, Modbus TCP, HTTPS, SSH, LDAP, RADIUS, TACACS+, RSTP, Syslog, NTP, DHCP, IPv4, and IPv6 — covering the majority of enterprise DCIM, BMS, and monitoring platform integrations.
Q: Is the VP4N30AC compatible with single-phase power circuits?
A: No. The VP4N30AC requires a three-phase 208V delta input. It is not compatible with single-phase 120V or split-phase 208V circuits. Confirm your facility's distribution architecture before specifying.
Q: What is the total outlet count and outlet type?
A: The VP4N30AC provides 24 locking IEC C13 outlets and 6 additional AC outlets, for a total of 30 AC outlets. The locking C13 design prevents accidental cord disconnection.

The VP4N30AC hits the right spec for three-phase delta data center cabinets that need real-time power visibility without the cost and complexity of per-outlet metering. The 30A / 208V delta rating via NEMA L15-30P gives you 8.6kW of distributed capacity — plenty for a dense 1U/2U server cabinet while staying comfortably within the 80% NEC continuous-load threshold at typical utilization.
Technical Highlights:
Deployment Considerations:
The VP4N30AC is the right specification for colocation operators and enterprise data center teams deploying homogeneous compute cabinets on three-phase delta circuits where aggregate power trending, AAA-integrated access control, and DCIM protocol breadth matter more than per-outlet granularity.