Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The VP4N62A3 is a horizontal, unit-level monitored power distribution unit rated at 60A with a 277/480V WYE three-phase input and 39.8KW total capacity. It is built for high-density data center rows and colocation cabinets where per-outlet monitoring is required to track actual load distribution across a rack — not just inlet-level current. With 24 Saf-D-Grid Series 400 outlets and a 277V output, this PDU is matched to high-voltage cabinet deployments where standard 120/208V PDUs hit their limits. The horizontal form factor means it mounts cleanly in a 1U or 2U rack position rather than consuming vertical rail space, which matters in fully populated 42U enclosures. At 31 lbs and 17.1 in wide × 3.4 in tall × 12 in deep, it fits standard 19-inch EIA rack profiles.
The VP4N62A3 is designed for use with Vertiv's Vertiv power infrastructure ecosystem, specifically cabinet deployments requiring high-voltage three-phase distribution. The 24 Saf-D-Grid Series 400 outlets are compatible with Anderson Saf-D-Grid locking connectors — confirm that your downstream power distribution and IT equipment power cords terminate in Saf-D-Grid Series 400 connectors before ordering. This outlet type is common in high-density AI compute, GPU cluster, and hyperscale server rows where per-outlet amperage tracking is operationally critical. Input feed must supply a 60A, 277/480V WYE three-phase circuit — verify your facility's electrical infrastructure supports this voltage class, as it is not interchangeable with standard 208V three-phase deployments.
This unit requires a 60A, 277/480V WYE three-phase feed — coordinate with a licensed electrician for the upstream circuit, as 480V infrastructure demands different breaker, conduit, and grounding standards than 208V racks. The horizontal orientation requires standard 19-inch rack mounting; confirm available 1U or 2U clearance in the target cabinet. At 31 lbs, two-person installation is advisable when inserting into a populated rack. Route input whip to a dedicated 60A breaker — do not share the upstream circuit with other loads. Review outlet load balance across all 24 Saf-D-Grid positions to avoid overloading any single branch circuit monitored by the unit.