Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The AP7585 is a 2U basic rack-mount power distribution unit (PDU) extender designed for high-density data center and equipment rack environments where you need to branch 32A of 230V power into four IEC 60320 C19 outlets — the heavy-duty locking connector standard used on high-draw servers, UPS units, and PDUs themselves. Unlike switched or metered PDUs, this unit keeps the footprint and configuration simple: no network card, no software, no management overhead. You get reliable, always-on power distribution in a 2U horizontal form factor that installs in the front or rear of a standard 19-inch rack.
If your deployment involves high-wattage compute or storage gear that demands C19 connections rather than the lighter C13 standard, the APC by Schneider Electric AP7585 is worth a direct look. It fits naturally into larger power architectures where a rack PDU is feeding downstream gear from a hardwired 32A circuit — common in colocation cabinets, server rooms, and dense edge deployments.
The AP7585 is a basic PDU — no SNMP card slot, no outlet switching, no metering. It integrates into your power architecture as a passive distribution point. Pair it with a UPS system that has a hardwire output or a matching C20 output feeding a C19 inlet if your UPS supports that path. For environments where you need per-outlet switching, energy monitoring, or remote reboot capability, step up to APC's metered or switched PDU families before committing to this model.
The C19 outlet type is compatible with IEC 60320 C20 plugs on server and network equipment PSUs rated at 16A or higher. Confirm that the connected equipment's power cords are C20-terminated before ordering — mixing C13/C14 gear on this unit requires adapters that add resistance and defeat the clean installation the hardwire input is designed for.
For PoE switch infrastructure feeding IP cameras or access control hardware, consider pairing rack power with a PoE switch on its own circuit to avoid mixing high-inrush server loads with network infrastructure on the same PDU branch.
Q: What type of input connection does the AP7585 use?
A: The AP7585 uses a hardwired 3-wire input — there is no plug or inlet connector. It connects directly to a dedicated 32A branch circuit during installation. This is a permanent installation approach, not a plug-and-play PDU.
Q: How many outlets does the AP7585 provide, and what type are they?
A: The AP7585 provides four IEC 60320 C19 outlets, each rated for high-draw equipment. C19 is the locking connector standard used on servers and gear with 16A PSUs. Equipment must have IEC 60320 C20 power cord connectors to mate directly.
Q: What is the maximum load capacity of the AP7585?
A: The AP7585 is rated at 32A input and 7,360 VA load capacity at 230V. Standard electrical practice recommends loading to no more than 80% of rated capacity on a continuous basis, which works out to approximately 5,888 VA for 24/7 operation.
Q: Is the AP7585 compatible with both 208V and 230V power systems?
A: Yes. The AP7585 accepts 200V, 208V, and 230V input, making it compatible with North American 208V three-phase data center circuits as well as European and international 230V single-phase supplies.
Q: Does the AP7585 include monitoring, switching, or metering capabilities?
A: No. The AP7585 is a basic PDU with no network management, outlet switching, or power metering. It distributes power passively. If you need per-outlet control or energy monitoring, you will need a metered or switched PDU from the APC lineup.
Q: What rack space does the AP7585 occupy, and how does it mount?
A: The AP7585 occupies 2U (89mm) and mounts horizontally in a standard 19-inch rack. It can be installed at the front or rear mounting position, with rear mounting preferred to keep power cords close to equipment PSUs.

The AP7585 is one of those units that solves a specific problem cleanly: you have a 32A hardwired circuit feeding a rack, and you need to distribute that capacity to four C19 devices without adding a managed layer you don't need or can't justify the cost of. The hardwire input is the right call for permanent installs — no plug to work loose under thermal cycling, no inlet rating to become the weak link in a 7,360 VA circuit.
Technical Highlights:
Deployment Considerations:
The AP7585 fits well in colocation cabinets and dedicated server rooms where a licensed electrician is commissioning the rack power feed and the operator wants a clean, zero-management C19 distribution point downstream of a UPS or PDU with a hardwire output. Not the right fit for environments where outlet-level visibility or remote reboot is a day-two operational requirement.