Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: SBP2200RM
UPC: 731304266754
Condition: New
Write a Review 32% OFF

APC by Schneider Electric SBP2200RM - Power Distribution Unit - 2U - 120 V - Circuit Breaker - NEMA

APC by Schneider Electric SBP2200RM 2U Rack Basic Power Distribution UnitOverviewThe SBP2200RM is a 2U rack-mount basic PDU from APC by Schneider Elec…

$561.00 $382.99 SAVE $178
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric SBP2200RM - Power Distribution Unit - 2U - 120 V - Circuit Breaker - NEMA

$561.00
$382.99

Overview

SKU: SBP2200RM
UPC: 731304266754
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric SBP2200RM 2U Rack Basic Power Distribution Unit

Overview

The SBP2200RM is a 2U rack-mount basic PDU from APC by Schneider Electric built to distribute 120V AC power across eight outlets in a 20A-maximum circuit — the kind of straightforward, no-frills distribution layer that belongs at the back of a security or IT rack where you need reliable, circuit-protected power to cameras, NVRs, switches, and ancillary equipment without added monitoring complexity. Rated at 2200 VA with a NEMA 5-20P input plug, it draws from a standard 20A commercial circuit and protects downstream gear through a built-in circuit breaker. If you're racking out a power distribution layout and need a dependable fixed-output PDU that doesn't require managed software or network access, the SBP2200RM covers that role cleanly in a 2U footprint.

Key Features

  • 2200 VA / 20A Load Capacity: At 2200 VA on a 20A circuit, this PDU can handle the full draw of a densely populated security rack — eight cameras at 15W each, a PoE switch, and an NVR still land well under ceiling. Size your load to 80% of rated capacity (1760W) to stay within safe continuous-draw limits.
  • 8 Total Outlets — Mixed 5-15R and 5-20R: The output side delivers six NEMA 5-15R outlets for standard 15A devices and two NEMA 5-20R outlets for 20A-rated equipment. That mix matters in a rack where most gear takes 5-15 plugs but your higher-draw appliances (some UPS bypass panels, high-density switches) need the 5-20R receptacle.
  • NEMA 5-20P Input Plug: Connects directly to a standard 20A commercial wall or floor circuit — no hardwiring required, no special connector adapters. Common in server rooms, data closets, and equipment rooms, so installation is typically plug-and-go once the circuit is in place.
  • Built-in Circuit Breaker: Provides overcurrent protection at the PDU level — if a downstream device faults and draws excess current, the breaker trips before the circuit damage propagates upstream or across other outlets. Faster recovery than a blown fuse; reset without replacing hardware.
  • 2U Rackmount Form Factor: Occupies 2U of vertical rack space. In a 12U or 16U edge rack, that's a meaningful fraction — confirm your remaining U count before ordering if space is tight. Mounts horizontally in a standard 19-inch rack.
  • 0–40°C Operating Temperature Range: Covers wiring closets, equipment rooms, and conditioned server spaces. Not rated for outdoor or unconditioned environments — if ambient temperature routinely exceeds 40°C, derate or choose an enclosure with active cooling.
  • RoHS Compliance and TÜV Certification: RoHS compliance limits hazardous substances in the hardware, relevant for deployments in government or regulated facilities. TÜV certification indicates independent third-party safety testing — relevant when procurement requires verified safety documentation.
  • Wide Operating Humidity Range (0–95%): Handles the humidity levels typical of commercial data rooms and security head-end spaces. Non-condensing environments are the target — condensation inside a PDU is a risk regardless of rated humidity tolerance.

Integration & Compatibility

The SBP2200RM is a passive distribution device — it has no network management, no outlet-level switching, and no metering. That means it integrates with any rack setup without driver conflicts or software dependencies, and it works equally well feeding network video recorders, PoE switches, access control panels, or any 120V equipment that draws within the 20A circuit limit. The mixed outlet configuration (5-15R and 5-20R) accommodates virtually all standard rack equipment. For installations requiring outlet-level control, remote reboot capability, or power consumption monitoring, step up to a managed or switched PDU in the APC PDU lineup — the SBP2200RM deliberately omits those features to keep the unit simple and cost-efficient. Pair with a compatible APC UPS unit upstream if runtime protection is needed; this PDU does not include battery backup.

Frequently Asked Questions

Q: What is the maximum current the SBP2200RM can handle?

A: The SBP2200RM supports a maximum input current of 20A per phase, with a total rated load of 2200 VA at 120V. Best practice is to keep continuous load at or below 80% of that rating — roughly 1760W — to avoid sustained operation at ceiling draw.

Q: What outlet types does the SBP2200RM provide?

A: It provides eight total outlets: six NEMA 5-15R (15A standard) and two NEMA 5-20R (20A). The input plug is a NEMA 5-20P, connecting to a standard 20A commercial circuit.

Q: Does the SBP2200RM have network management or outlet switching?

A: No. The SBP2200RM is a basic PDU — it provides passive power distribution and circuit breaker protection only. There is no network interface, no outlet-level switching, and no metering capability. For managed functionality, a different APC PDU model is required.

Q: Is the SBP2200RM compatible with international voltage?

A: The SBP2200RM is rated for 120V nominal input at 50–60 Hz. It is designed for North American 120V infrastructure and is not suitable for 230V markets without a step-down transformer.

Q: What rack space does the SBP2200RM occupy?

A: It is a 2U rackmount unit, designed for standard 19-inch equipment racks. Confirm available U space in your rack before ordering.

Q: What certifications does the SBP2200RM carry?

A: The SBP2200RM carries RoHS compliance and TÜV certification. RoHS limits hazardous materials in the hardware; TÜV certification reflects independent third-party safety testing.

Specifications
PDU types: Basic
Product colour: Black
AC outlets quantity: 8 AC outlet(s)
Power plug: NEMA 5–20P
Output connections: 6 x NEMA 5-15R & 2 x NEMA 5-20R
Nominal input voltage: 120 V
AC input frequency: 50 - 60 Hz
Nominal output voltage: 120 V
Load capacity: 2200 VA
Maximum input current per phase: 20 A
Maximum total current draw per phase: 20 A
Compliance certificates: RoHS
Certification: TUV
Operating temperature (T-T: 0 - 40 °C
Storage temperature (T-T: -15 - 45 °C
Operating relative humidity (H-H: 0 - 95%
Storage relative humidity (H-H: 0 - 95%
Operating altitude: 0 - 4500 m
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources