Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The AP7598 is a basic zero-rack-unit (Zero-U) power distribution unit delivering 12.5kW at 208V across 36 outlets — 30 C13 and 6 C19 receptacles — on a 10-foot input cord. Zero-U mounting runs the PDU vertically along the interior rail of a standard EIA-310 rack, consuming no horizontal rack space, which matters when every rack unit is committed to active equipment. At 12.5kW / 208V, this PDU is sized for high-density server or networking rows where per-outlet loads vary from 1U switches to dual-PSU servers. The 50/60 Hz frequency rating accommodates both North American and international data center power infrastructure where 208V three-phase or single-phase feeds are common. The C19 receptacle group handles higher-draw devices (up to 16A per IEC standard) — useful for dual-corded servers or high-density storage nodes — while the 30 C13 positions cover 1U/2U switching and compute gear. Basic-tier means no outlet-level switching or metering; this is a rack power distribution unit focused on reliable always-on connectivity, not remote management. If your rack requires per-outlet control or power monitoring, look at APC's Switched or Metered PDU families within the APC by Schneider Electric lineup.
Fits standard 19-inch EIA-310 two-post and four-post open-frame racks and enclosed cabinets with vertical PDU mounting channels — including APC NetShelter SX, SV, and VX series enclosures. The C13/C19 outlet mix is compatible with standard IEC 60320 power cords used on Cisco, HPE, Dell, and Lenovo rack servers, as well as network switches and patch panels drawing from a 208V branch circuit. Confirm your upstream breaker and PDU input plug type before ordering — 208V PDUs are not interchangeable with 120V infrastructure. Pair with a compatible UPS system rated for 208V output to maintain runtime protection across the full 12.5kW load.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more APC by Schneider Electric products? Shop the full APC by Schneider Electric catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price