APC by Schneider Electric Rack PDU 2G Metered Zerou 20A 208V 3PH (24) 5-20R (6) L6-20R - AP8863

APC by Schneider Electric AP8863 Metered Zero-U 3-Phase Rack PDUOverviewThe APC by Schneider Electric AP8863 is a 2G metered, Zero-U rack power distri…

$1,485.00 $991.99 SAVE $493
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric Rack PDU 2G Metered Zerou 20A 208V 3PH (24) 5-20R (6) L6-20R - AP8863

$1,485.00
$991.99

Overview

SKU: AP8863
UPC: 731304307495
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric AP8863 Metered Zero-U 3-Phase Rack PDU

Overview

The APC by Schneider Electric AP8863 is a 2G metered, Zero-U rack power distribution unit built for high-density three-phase data center and server room environments. Rated at 20A/208V across a NEMA L21-20P three-phase input, it delivers 5,760 VA of capacity across 30 outlets — 24x NEMA 5-20R for standard 1U/2U servers and 6x NEMA L6-20R for higher-draw equipment up to 208V. The Zero-U form factor installs vertically along the interior rail of a standard rack, preserving all horizontal U-space for compute and storage hardware. If you're distributing three-phase power in a dense rack where every rack unit counts, the AP8863 is the correct tool.

Current monitoring is built in via an LED display with alarm indicators, giving you real-time per-phase load visibility at the unit without requiring a network connection or management console. This matters on the data center floor where a technician needs to confirm phase balance before adding a new load — no laptop required.

Key Features

  • 30-Outlet Capacity (24x 5-20R + 6x L6-20R): The outlet mix covers the two most common load types in a mixed rack — standard 120V servers on the 5-20R side and 208V dual-corded equipment (UPS bypass, higher-draw storage) on the L6-20R side. You won't need a second PDU just to accommodate a single 208V device.
  • 20A / 208V Three-Phase Input (NEMA L21-20P): Three-phase input at 208V means balanced load distribution across phases, reducing current per conductor versus a single-phase equivalent. At 20A maximum per phase with a 16A maximum continuous draw per phase (80% derating per NEC), you have 5,760 VA total — sufficient for a fully loaded 42U rack of mid-density 1U servers.
  • Zero-U Vertical Mounting: Installing vertically in the rack's cable management channel means zero horizontal rack units consumed. In a co-location environment where rack space is billed per U, this distinction has a direct dollar value. The 1.83m (6 ft) cord provides enough reach to route cleanly to a floor PDU or busway tap without excessive slack.
  • Per-Phase Metered Monitoring with LED Display: Real-time current monitoring per phase via the onboard LED display lets rack technicians confirm load balance during provisioning. The alarm LED triggers on overload or threshold breach — a passive alert that doesn't require a networked management path to catch a runaway load.
  • 120–208V Nominal Output Range: Output spans 120V (5-20R outlets) through 208V (L6-20R outlets) from the same unit, eliminating the need for step-down transformers for legacy 120V equipment in a 208V three-phase environment.
  • RoHS, UL 60950-1, cUL Listed, FCC Part 15 Class A, REACH: The full compliance stack — UL 60950-1 for IT equipment safety, cUL for Canadian deployment, FCC Class A for commercial/industrial RF emissions, REACH and RoHS for environmental compliance — means this unit clears procurement and compliance review at enterprise and government accounts without needing special exceptions.
  • 50–60 Hz Input Frequency: Accepts both 50 Hz and 60 Hz input, which matters if the same rack configuration is being deployed across US (60 Hz) and international (50 Hz) data center sites. One SKU handles both without a separate international variant.

Integration and Compatibility

The AP8863 connects to any facility power panel or floor PDU providing a NEMA L21-20P three-phase 20A circuit at 208V — the standard three-phase wye configuration in North American data centers. The rack PDU is compatible with all standard 19-inch two-post and four-post racks. As a metered-only (not switched, not managed) unit, it has no network interface and requires no IP address, firmware management, or software licensing — reducing the attack surface and eliminating ongoing software overhead. For deployments that need remote outlet switching or network-level monitoring, consider a switched or managed variant in the APC by Schneider Electric rack PDU line.

The Zero-U form factor pairs naturally with high-density server rack enclosures where cable management channels accommodate vertical PDU mounting on one or both sides. If your rack infrastructure planning requires detailed data center power distribution guidance, outlet density and phase load calculations should be confirmed before finalizing the number of PDUs per rack.

Frequently Asked Questions

Q: What is the maximum continuous current draw per phase on the AP8863?

A: The AP8863 is rated at 20A maximum input per phase, with a maximum continuous draw of 16A per phase — consistent with the NEC 80% continuous load rule. Exceeding 16A continuous on any phase will trigger the alarm indicator.

Q: Does the AP8863 have network management or remote monitoring capability?

A: No. The AP8863 is a metered PDU only — it provides local current monitoring via an onboard LED display with alarm indication. It has no network interface, no SNMP, and no remote management capability. For networked monitoring, you would need a managed or switched PDU variant.

Q: What input plug does the AP8863 require?

A: The AP8863 uses a NEMA L21-20P input connector, which requires a three-phase 208V 20A circuit with a matching L21-20P receptacle or hardwired connection. Confirm your facility's panel or floor PDU provides this circuit before ordering.

Q: Can the AP8863 be mounted horizontally in a rack?

A: The AP8863 supports both horizontal and vertical mounting. The Zero-U designation refers to its ability to mount vertically in the rack's side channel without consuming horizontal rack units — the preferred installation for maximizing usable rack space.

Q: Is the AP8863 compliant with RoHS and REACH environmental directives?

A: Yes. The AP8863 carries both RoHS and REACH compliance certifications, along with UL 60950-1, cUL Listed, FCC Part 15 Class A, and ICES-003 — covering environmental, safety, and RF emissions requirements for commercial deployment in North America.

Q: What is the total VA capacity of the AP8863?

A: The AP8863 delivers a maximum load capacity of 5,760 VA at 208V three-phase input. This is the theoretical maximum; practical continuous load should be sized at or below 4,608 VA (80% of rated capacity) per standard NEC derating practice.

Jerry Tildsen
Jerry Tildsen

The AP8863 is the unit I reach for when a rack needs three-phase 208V distribution and the integrator wants to preserve every rack unit for compute. The 16A-per-phase continuous rating is the number that actually governs your design — not the 20A nameplate — and at 5,760 VA total across 30 outlets, this PDU can handle a fully loaded mixed rack of 1U servers and dual-corded 208V storage without a second unit alongside it.

Technical Highlights:

  • 30-Outlet Density (24x 5-20R + 6x L6-20R): The 4:1 ratio of 120V to 208V outlets maps directly to how most server racks are actually loaded — the majority of 1U/2U compute runs on 120V, with a minority of higher-draw or dual-corded 208V devices. No rewiring, no adapters.
  • Zero-U Vertical Form Factor: The 1.83m cord length is just right for a standard 42U rack — enough to reach a floor PDU tap cleanly without coiling excess cable in the channel. Horizontal mounting is supported, but vertical is the deployment that earns the Zero-U designation.
  • Metered with Per-Phase LED Alarm: Local current monitoring with an alarm output catches a runaway load before it trips the breaker. In an unmanned co-lo cage, even a passive local indicator is one more layer of protection against silent overload.

Deployment Considerations:

  • Confirm your facility circuit is wired L21-20P at 208V three-phase before the unit ships — retrofitting a different plug or using an adapter on a 20A circuit is not a compliant solution and voids the UL listing.
  • The AP8863 has no network interface. If your operations team expects SNMP traps or integration with a data center infrastructure management (DCIM) platform, you need the managed or switched variant — metered-only means local eyes only.

This unit fits best in co-location environments and enterprise server rooms where three-phase 208V is the facility standard, rack space is at a premium, and the monitoring requirement is satisfied by local LED indication rather than a networked management plane. It is not the right pick for environments that require remote outlet control, per-outlet metering, or integration with a DCIM tool.

Specifications
PDU types: Metered
Mounting: Horizontal/Vertical
Product colour: Black
Display: LED
AC outlets quantity: 30 AC outlet(s)
AC outlet types: NEMA 5–20R, NEMA L6-20R
Input connection type: NEMA L21-20P
LED indicators: Alarm
Cable length: 1.83 m
Monitoring: Current
Nominal input voltage: 208 V
AC input frequency: 50 - 60 Hz
Maximum current: 20 A
Nominal output voltage: 120-208 V
Load capacity: 5760 VA
Maximum total current draw per phase: 16 A
Compliance certificates: RoHS
Certification: cUL Listed, FCC Part 15 Class A, ICES-003, UL 60950-1, UL Listed, REACH
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources