Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric APDU11551ME Metered 3-Phase Rack PDU

Overview

The APDU11551ME is a 0U vertical-mount, three-phase metered rack PDU from APC's Netshelter Advanced 11K series, designed for high-density data center and server room deployments running 208V, 3-phase power at up to 100A. At 28,800 VA load capacity and with NMC3 network management card support, this unit gives power administrators real-time branch-circuit-level visibility without adding horizontal rack space — the vertical 0U form factor keeps all 30 outlets accessible along the side rail of standard open-frame or enclosed racks. This is the right PDU when you're powering dense compute or network rows where per-outlet monitoring and remote management from a central NMS matters operationally.

Compatibility

The APDU11551ME is engineered for APC Netshelter SX, SV, and VX series racks, where the vertical mounting channel accommodates the 0U profile. The 30-outlet mix — C13, C15, C19, and C21 couplers — covers server, storage, and high-wattage GPU workloads on a single distribution unit. Input connects via IEC 60309 plug, so the feed circuit must be provisioned with a matching IEC 60309 receptacle or hardwired panel connection rated for 80/100A at 208V 3-phase. NMC3 integration connects this PDU to APC UPS and power management infrastructure, allowing unified management through EcoStruxure IT or compatible DCIM platforms. Works alongside other APC by Schneider Electric rack PDU families for mixed-density rows.

Installation Notes

Operating temperature range is -5°C to 60°C with 5–90% relative humidity (non-condensing) — standard data center environmental envelope. The IP67 rating means the unit is sealed against dust ingress and temporary water immersion, which is relevant if deploying in edge or industrial environments subject to wash-down or condensation. Input frequency accepts 50 or 60 Hz, so the unit deploys globally without derating. Verify your upstream breaker is rated for the full 100A draw before provisioning high-wattage loads across all 30 outlets simultaneously; typical rack enclosure branch-circuit design recommends loading to 80% of rated capacity (80A continuous) for thermal headroom. NMC3 requires a network drop at the PDU location for remote monitoring to function — factor that into switch port planning in dense rows.

Specifications
PDU types: Metered
Type: Three-phase
Rack capacity: 0U
Mounting: Vertical
Product colour: Black
AC outlets quantity: 30 AC outlet(s)
Power plug: IEC 60309
AC outlet types: C15 coupler, C13 coupler, C19 coupler, C21 coupler
International Protection (IP) code: IP67
Management platform: NMC3
Nominal input voltage: 208 V
AC input frequency: 50/60 Hz
Maximum current: 100 A
Output voltage: 208 V
Load capacity: 28800 VA
Operating temperature (T-T: -5 - 60 °C
Storage temperature (T-T: -20 - 60 °C
Operating relative humidity (H-H: 5 - 90%
Q&A
Reviews

APC by Schneider Electric 0U 3PH 208V 80/100A Metered PDU - APDU11551ME

$9,590.00
$6,497.99

RELATED PRODUCTS

Save $3,356.01
APC Netshelter Rack PDU Advanced 11K Series, Metered, 0U, 3PH, 415V, 80/100A, 51
Add to Cart The item has been added

APC by Schneider Electric APDU11550ME

APC by Schneider Electric APDU11550ME 0U 3PH 415V 80/100A PDU

0U vertical-mount, three-phase metered rack PDU from the APC Netshelter Advanced 11K Series , engineered for high-density data center cabinets and

    Usually Ships in 2-3 Weeks Free shipping over $499
    $10,080.00 $6,723.99 Save $3,356.01
    The item has been added Add to quote
    $10,080.00 $6,723.99 Save $3,356.01
    Save $3,356.01 Add to cart Add to quote
    Save $2,275.01
    APC Netshelter Rack PDU Advanced Metered Outlet 3PH 17.3KW 208V 60A 460P9 - APDU
    Add to Cart The item has been added

    APC by Schneider Electric APDU10452MO

    APC by Schneider Electric Metered PDU 3PH 17.3KW 208V 60A - APDU10452MO

    3-phase, 208V/60A rack-mount power distribution unit designed for high-density data center and enterprise server environments where outlet-level

      Usually Ships in 2-3 Weeks Free shipping over $499
      $7,015.00 $4,739.99 Save $2,275.01
      The item has been added Add to quote
      $7,015.00 $4,739.99 Save $2,275.01
      Save $2,275.01 Add to cart Add to quote
      Save $1,151.01
      APC Netshelter Rack PDU Advanced Metered 3PH 17.3KW 208V 60A 460P9 42 OUT - APDU11452ME
      Add to Cart The item has been added

      APC by Schneider Electric APDU11452ME

      APC by Schneider Electric APDU11452ME Metered 3PH PDU

      3-phase advanced metered rack PDU delivering 17.3kW at 208V/60A — engineered for high-density data center cabinets where per-outlet visibility and

        Usually Ships in 2-3 Weeks Free shipping over $499
        $4,590.00 $3,438.99 Save $1,151.01
        The item has been added Add to quote
        $4,590.00 $3,438.99 Save $1,151.01
        Save $1,151.01 Add to cart Add to quote

        System Design, Deployment & Technical Support

        Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

        Fixed scope • Fixed price

        System Design Assistance

        • Get help validating product compatibility
        • Coverage requirements
        • Storage planning and deployment architecture before you buy.
        Request Design Help

        Deployment & Configuration Support

        • Access fixed-scope support for rollout planning
        • User setup guidance
        • Migration and system standardization across single-site or multi-site deployments
        View Support Services

        Guides, Tools & Calculators

        • PoE requirements
        • Storage retention
        • Camera selection and deployment methodology
        Open Technical Resources