Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric SUVTP15KF2B2S 15kVA 208V Tower UPS

Overview

The APC by Schneider Electric SUVTP15KF2B2S is a 15 kVA tower-form uninterruptible power supply built for medium-to-large commercial and enterprise environments where load protection, runtime assurance, and remote manageability are non-negotiable. Rated for 208V AC output with a 220V AC input, this unit handles up to 40A of input current — sized for power-dense equipment rooms, data closets, and security operation centers running continuous workloads. At 873 lb and 59 inches tall, this is a floor-standing, dedicated power infrastructure deployment, not a rack afterthought.

The SUVTP15KF2B2S sits in the APC by Schneider Electric Smart-UPS VT line, which targets mission-critical applications where both automatic and manual static bypass capabilities matter. If your facility's power team needs to perform maintenance without dropping protected loads, that dual-bypass architecture is the spec to evaluate first.

Key Features

  • 15 kVA Load Capacity: Enough headroom to protect a dense rack of network video recorders, PoE switches, and server infrastructure simultaneously — without running close to the thermal ceiling that shortens battery life on undersized units.
  • 10-Minute Full-Load Runtime / 28.1-Minute Half-Load Runtime: At full 15 kVA draw, you get 10 minutes of bridge time — enough for an orderly shutdown or generator transfer. Shed load to 50% and that extends to 28.1 minutes, which matters if your NVR or video management server needs time to flush buffers and write indexes cleanly before power cuts.
  • Lead Acid Battery Chemistry / 5-Hour Recharge: After a full discharge event, the unit returns to full capacity in 5 hours. Plan maintenance windows accordingly — if you have back-to-back power incidents within a single shift, the second event may catch you with partial battery reserve.
  • Automatic Bypass Switch: The unit transfers to bypass automatically if internal components fail or if overload conditions exceed the inverter's capacity. Protected loads stay powered; the UPS steps aside without manual intervention. Critical in unmanned equipment rooms.
  • Manual Static Maintenance Bypass: Facilities and power engineers can isolate the UPS for battery replacement or internal servicing while maintaining power to downstream equipment. This is the operational feature that separates enterprise-class UPS deployments from prosumer units — zero-downtime maintenance is possible.
  • SNMP-Manageable via SmartSlot: The SmartSlot expansion bay accepts APC network management cards, enabling SNMP-based monitoring, alerting, and remote shutdown scripting through your existing NMS or network management infrastructure. Without an installed management card, SNMP capability is present as a slot — the card itself is a separate purchase.
  • 208V AC / 120V AC Dual Output Voltage: Serves both standard 120V AC single-phase loads and 208V AC equipment from a single unit. Useful in mixed-equipment rooms where servers, storage arrays, and building systems draw different voltages.
  • 70 Hz Input Frequency Tolerance: Accepts input frequencies up to 70 Hz, providing tolerance for generator power that may run slightly off nominal 60 Hz during startup or load transients — a practical consideration for facilities that depend on diesel backup generation.

Integration & Compatibility

The SUVTP15KF2B2S integrates with APC's PowerChute software suite via an installed SmartSlot network management card, enabling scheduled shutdowns, event logging, and UPS status feeds into DCIM or BMS platforms. The SNMP interface supports standard MIB-based integration with Nagios, SolarWinds, PRTG, and most enterprise network management systems. Output frequency is fixed at 60 Hz, which means downstream equipment with tight frequency tolerances will see stable power regardless of generator input variation. Pair this unit with a compatible APC maintenance bypass panel if your installation requires external bypass capability beyond the built-in static bypass.

Frequently Asked Questions

Q: What is the full-load runtime of the SUVTP15KF2B2S?

A: At full 15 kVA load, the SUVTP15KF2B2S provides approximately 10 minutes of battery runtime. At half load (7.5 kVA), runtime extends to 28.1 minutes.

Q: Does the SUVTP15KF2B2S include a network management card?

A: The unit includes a SmartSlot expansion bay that accepts APC network management cards for SNMP monitoring and remote management. The management card itself is a separate accessory and is not included in the base unit.

Q: Can I service the SUVTP15KF2B2S without taking downstream equipment offline?

A: Yes. The unit includes a manual static maintenance bypass that allows trained personnel to isolate the UPS for battery replacement or internal servicing while keeping connected loads powered through bypass.

Q: What input voltage and current does the SUVTP15KF2B2S require?

A: The SUVTP15KF2B2S requires 220V AC input at up to 40A. Verify that your facility's electrical circuit and breaker are rated for this draw before installation.

Q: How long does it take to recharge the SUVTP15KF2B2S battery after a full discharge?

A: Typical battery recharge time from full discharge is approximately 5 hours. Plan maintenance windows or generator test schedules with this recharge window in mind.

Q: What is the warranty on the SUVTP15KF2B2S?

A: The SUVTP15KF2B2S carries a 1-year manufacturer warranty.

Karl Wilson
Karl Wilson

The SUVTP15KF2B2S is the unit I reach for when a project spec calls for 15 kVA of protected 208V power in a tower footprint with zero tolerance for maintenance downtime. That manual static bypass isn't a checkbox — it's what separates a Tuesday-afternoon battery swap from a full site shutdown. At 873 lb and 59 inches, this is a serious floor commitment; confirm your raised-floor load rating and dock access before it ships.

Technical Highlights:

  • Dual Bypass Architecture: Automatic bypass handles unexpected overload or internal fault conditions without manual intervention; the manual static bypass lets you pull the UPS out of circuit for scheduled maintenance while loads stay live on utility power. Both are present on this unit — not an either/or choice.
  • 28.1-Minute Half-Load Runtime: If your protected load averages closer to 7–8 kVA rather than the full 15, you're looking at nearly 30 minutes of runtime — enough for a full generator transfer sequence plus confirmation checks, which matters in facilities where the genset takes 45–90 seconds to reach stable voltage.
  • 70 Hz Input Tolerance: Generator power during startup and load transients can drift well above 60 Hz. The 70 Hz upper input tolerance means this unit won't trip offline during a generator startup sequence — a failure mode I've seen bring down lesser UPS deployments.

Deployment Considerations:

  • The SmartSlot bay is present but the network management card is a separate line item. Budget and order it alongside the UPS — SNMP monitoring is essentially required for any managed deployment, and arriving on-site without the card means a second visit.
  • At 40A input draw, this unit needs a dedicated 50A circuit minimum (80% NEC rule). Confirm panel capacity and breaker sizing with the electrical contractor before the unit arrives — this is not a plug-and-play installation.

This unit is the right call for a physical security operations center or large enterprise equipment room where 208V protected power, zero-downtime serviceability, and SNMP integration into an existing NMS are all required in a single tower deployment.

Specifications
Load Capacity: 15 kVA
Backup Run Time Full Load: 10 Minute
Backup Run Time Half Load: 28.10 Minute
Output Voltage: 120 V AC | 208 V AC
Input Voltage: 220 V AC
Input Frequency: 70 Hz
Output Frequency: 60 Hz
Input Current: 40 A
Network Management: SNMP Manageable
Bypass Switch: Automatic
Maintenance Bypass: Manual Static
Modular Slots: SmartSlot
Battery Chemistry: Lead Acid
Typical Battery Recharge Time: 5 Hour
Form Factor: Tower
Height: 59"
Width: 14"
Depth: 32"
Weight: 873 lb
Warranty: 1 Year
Q&A
Reviews
Have Questions?

APC by Schneider Electric SMART-UPS VT 15KVA - SUVTP15KF2B2S

$15,940.00
$10,527.99

RELATED PRODUCTS

Save $6,027.01
Image coming soon
Add to Cart The item has been added

APC by Schneider Electric SUVTP15KF3B4S

APC by Schneider Electric SMART UPS VT 15KVA - SUVTP15KF3B4S

15kVA, 208V 3-phase uninterruptible power supply (UPS) designed to provide robust battery backup and power conditioning for demanding IT environments

    Usually Ships in 2-3 Weeks Free shipping over $499
    $17,840.00 $11,812.99 Save $6,027.01
    The item has been added Add to quote
    $17,840.00 $11,812.99 Save $6,027.01
    Save $6,027.01 Add to cart Add to quote
    Save $5,807.01
    APC by Schneider Electric Smart-ups VT 15KVA 208V W/2 Batt MOD EXP TO 4, Start-up 5X8, INT Maint Bypass, P
    Add to Cart The item has been added

    APC by Schneider Electric SUVTP15KF2B4S

    APC by Schneider Electric VT 15KVA UPS - SUVTP15KF2B4S

    15 kVA / 12,000W three-phase-input rackmount uninterruptible power supply built for data centers, server rooms, and critical infrastructure

      Usually Ships in 2-3 Weeks Free shipping over $499
      $17,080.00 $11,272.99 Save $5,807.01
      The item has been added Add to quote
      $17,080.00 $11,272.99 Save $5,807.01
      Save $5,807.01 Add to cart Add to quote
      Save $1,501.01
      Image coming soon
      Add to Cart The item has been added

      APC by Schneider Electric SUVTSBP10K15F

      APC by Schneider Electric SMART-UPS VT 10-15KVA FLOOR - SUVTSBP10K15F

      N external battery pack designed to extend the runtime of compatible APC SMART-UPS VT 10-15KVA uninterruptible power supply systems

        Usually Ships in 2-3 Weeks Free shipping over $499
        $4,515.00 $3,013.99 Save $1,501.01
        The item has been added Add to quote
        $4,515.00 $3,013.99 Save $1,501.01
        Save $1,501.01 Add to cart Add to quote
        Save $7,719.01
        APC by Schneider Electric MGE Galaxy 3500 15KVA 400V - G35T15KH4B4S
        Add to Cart The item has been added

        APC by Schneider Electric G35T15KH4B4S

        APC by Schneider Electric G35T15KH4B4S 15KVA UPS

        15 kVA / 12,000 W three-phase double-conversion UPS designed for data centers, industrial control rooms, and enterprise infrastructure where a

          Usually Ships in 2-3 Weeks Free shipping over $499
          $23,965.00 $16,245.99 Save $7,719.01
          The item has been added Add to quote
          $23,965.00 $16,245.99 Save $7,719.01
          Save $7,719.01 Add to cart Add to quote
          Save $5,225.01
          APC by Schneider Electric MGE Galaxy 3500 15KVA 208V With 2 Battery Modules Expandable TO 4, Start-up 5X8
          Add to Cart The item has been added

          APC by Schneider Electric G35T15KF2B4S

          APC by Schneider Electric G35T15KF2B4S 15KVA UPS

          15 kVA / 12,000W three-phase-input, single-phase-output online double-conversion UPS designed for mid-tier data center rows, network equipment rooms

            Usually Ships in 2-3 Weeks Free shipping over $499
            $16,225.00 $10,999.99 Save $5,225.01
            The item has been added Add to quote
            $16,225.00 $10,999.99 Save $5,225.01
            Save $5,225.01 Add to cart Add to quote

            System Design, Deployment & Technical Support

            Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

            Fixed scope • Fixed price

            System Design Assistance

            • Get help validating product compatibility
            • Coverage requirements
            • Storage planning and deployment architecture before you buy.
            Request Design Help

            Deployment & Configuration Support

            • Access fixed-scope support for rollout planning
            • User setup guidance
            • Migration and system standardization across single-site or multi-site deployments
            View Support Services

            Guides, Tools & Calculators

            • PoE requirements
            • Storage retention
            • Camera selection and deployment methodology
            Open Technical Resources