Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Panduit PR2VD06 PatchRunner 2 Vertical Dual-Sided Cable Manager
The Panduit PR2VD06 solves high-density cable routing in datacenters and network closets where floor space is at a premium and accessibility from both sides of the rack matters. This 45RU dual-sided vertical manager ships fully pre-assembled, eliminating field assembly labor and reducing deployment time on multi-rack installations. The 6-inch width profile maximizes cable capacity without consuming excessive aisle space, while dual full-length metal doors with push-to-close hinges provide secure, tool-free access to both cable channels. Built on a metal backbone with molded plastic fingers, the PR2VD06 balances structural rigidity with snag-free cable retention across the full 83.88-inch height.
Key Features
- 45RU vertical capacity supports high-density racks up to standard 42U equipment height plus overhead cable routing
- Dual-sided design with independent access to front and rear cable channels for cross-connect installations or separate zone management
- 6-inch (152.4mm) width balances high cable capacity with narrow aisle footprint in space-constrained server rooms
- Fully pre-assembled construction eliminates field assembly, reducing installation labor by approximately 30-45 minutes per unit
- Metal backbone provides structural rigidity under full cable load (typical 200+ Cat6A cables per side)
- Molded plastic cable retention fingers prevent snags during moves/adds/changes and guide cables through vertical runs
- Dual full-length metal doors with dual-hinging, push-to-close latches secure cables without tools and swing clear for unobstructed access
- UL 2416 listed for use in information technology equipment racks, CSA C22.2 certified, RoHS compliant for commercial datacenter environments
The PR2VD06 construction addresses the two failure modes common in vertical cable managers: backbone flex under load and cable jacket damage during service. The metal backbone runs the full 83.88-inch height and mounts to standard 19-inch or 23-inch racks at multiple points, preventing the lateral sway that occurs when fully loaded managers are mounted only at top and bottom. This rigidity is critical when the manager holds 400+ cables (200 per side) in a dense Cat6A or fiber installation—total cable weight can exceed 80 pounds, and any flex translates to tension on patch cords at the switch ports. The molded plastic fingers are rounded at all contact points and spaced to guide cables vertically without sharp bends, meeting the 4x bend radius requirement for Cat6A (approximately 1 inch radius for 0.25-inch cable diameter) across the full vertical run. Unlike stamped metal fingers, the plastic design eliminates burrs and edges that can nick cable jackets during installation or subsequent moves. The dual-sided architecture means each side operates independently: front-side fingers hold switch-to-panel patch cords while rear-side fingers manage backbone cables to other racks, or you can dedicate one side to copper and the other to fiber to maintain separation. The full-length doors on each side latch at multiple points along the height, preventing the door-sag that leaves the top third of the manager exposed after a few months of use. Push-to-close latches require no tools and no finger strength—push the door edge and it draws closed and latches in one motion, a detail that matters when a tech is holding a cable bundle with one hand and needs to secure the door with the other.
Deploy the PR2VD06 in scenarios where dual-sided access drives efficiency or where physical separation of cable types is required by standards or best practice. In leaf-spine datacenter architectures, mount one PR2VD06 between every two racks of leaf switches: front side manages horizontal patch cords to servers in the adjacent racks, rear side manages vertical spine uplinks that run overhead to the core switches. In network closets serving multi-tenant floors, use the front side for tenant A's connections and the rear side for tenant B's, maintaining physical separation without needing two separate managers. In hybrid copper-fiber environments, dedicate one side to copper patch cords (which require larger bend radius and more finger spacing) and the other side to fiber (which benefits from tighter guidance to prevent sagging). The 6-inch width is optimized for racks with 400-600mm depth (typical server/network racks): it provides enough capacity for 200+ cables per side without protruding into the aisle or interfering with rack door swing. If your racks are spaced on 600mm centers in a hot-aisle/cold-aisle layout, a 6-inch manager leaves enough clearance for techs to work from the aisle without stepping into the opposing row. The 45RU height (83.88 inches) fits standard datacenters with 8-foot raised floor-to-ceiling heights: allows mounting at floor level with the top of the manager clearing a 42U rack by several inches, providing the vertical space needed to route cables overhead into ladder rack or cable tray. For installations where cables enter from above (overhead tray) rather than below (under-floor), mount the manager so the top aligns with the top of the equipment rack and the bottom extends a few RU below the lowest switch—uncommon but valid in retrofit scenarios where under-floor access is obstructed.
The PR2VD06 is UL 2416 listed, the standard for rack-mounted cable management accessories used with information technology equipment, which requires flame rating (94V-0 or better for plastic components, non-combustible for metal) and mechanical load testing to ensure the manager does not collapse or detach under rated cable load. This certification is required by many enterprise datacenter operators and is checked during facility audits for insurance and compliance purposes. CSA C22.2 certification extends the same testing to Canadian electrical code, relevant for cross-border deployments or organizations with facilities in both US and Canada that maintain a single approved-vendor list. RoHS compliance means the unit contains no lead, mercury, cadmium, hexavalent chromium, or restricted flame retardants above the threshold limits, which matters for organizations with environmental procurement policies or for equipment destined for European datacenters where RoHS is legally required. The pre-assembled design reduces your installation labor to four steps: mount the manager to the rack rails at the specified RU positions, verify vertical alignment with a level, torque the mounting hardware to 40 in-lbs, and swing the doors to confirm latch operation. No finger assembly, no door hinging, no separate hardware bags. On a 10-rack datacenter buildout, this saves approximately 5-6 hours of tech time compared to field-assembly managers, and eliminates the QC step of checking that fingers are installed in the correct orientation (a common field error that results in cables sitting between fingers rather than inside them).
Panduit PR2VD06 45RU Dual-Sided Cable Manager
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Panduit products? Shop the full Panduit catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology