UPS & Power Management
Showing Results for UPS & Power Management
-
APC by Schneider Electric
SKU: SMT750J
APC Smart-ups 750VA LCD 100V - SMT750J
In stock · Ships same business day$1,410.00 $941.99 Save $468.01 -
APC by Schneider Electric
SKU: SMT750RM1U
APC Smart-ups 750VA LCD 120V 1U Rackmount - SMT750RM1U
In stock · Ships same business day$1,175.00 $783.99 Save $391.01 -
APC by Schneider Electric
SKU: SMT750CUS
APC Smart-ups 750VA LCD 120V US - SMT750CUS
In stock · Ships same business day$929.00 $620.99 Save $308.01 -
APC by Schneider Electric
SKU: SMT750C
APC Smart-ups 750VA LCD 120V- Line-interactive - 500WATT - 750VA - NEMA 5-15P 6 - SMT750C
In stock · Ships same business day$743.00 $498.99 Save $244.01 -
APC by Schneider Electric
SKU: SMT750IC
APC Smart-ups 750VA LCD 230V with Smartconnect - SMT750IC
In stock · Ships same business day$564.99 $524.99 Save $40.00 -
APC by Schneider Electric
SKU: SMT750R2X122
APC Smart-UPS 750VA LCD RM 2U 120V with L5-15P - SMT750R2X122
In stock · Ships same business day$863.00 $576.99 Save $286.01 -
APC by Schneider Electric
SKU: SMT750RMI2UNC
APC Smart-UPS 750VA LCD RM 2U 230V with Network Card - SMT750RMI2UNC
In stock · Ships same business day$2,305.00 $1,720.99 Save $584.01 -
APC by Schneider Electric
SKU: SMTL750RM2UCNCITE
APC Smart-ups 750VA Lithium-ion 2U 120V Smartconnect+network Card W/ 1 NOD - SMTL750RM2UCNCITE
In stock · Ships same business day$2,985.00 $1,987.99 Save $997.01 -
APC by Schneider Electric
SKU: SMT750RM2UC
APC Smart-ups 750VA RM 2U 120V- Line-interactive - 500WATT - NEMA 5-15P 6 NEMA 5 - SMT750RM2UC
In stock · Ships same business day$983.00 $657.99 Save $325.01 -
APC by Schneider Electric
SKU: SMC1000I-2U
APC Smart-UPS C 1000VA LCD RM 2U 230V - SMC1000I-2U
In stock · Ships same business day$1,040.00 $777.99 Save $262.01 -
APC by Schneider Electric
SKU: SMC1500I
APC Smart-UPS C 1500VA LCD 230V - SMC1500I
In stock · Ships same business day$1,225.00 $912.99 Save $312.01 -
APC by Schneider Electric
SKU: CSH2
APC Smart-ups Charge Mobile Battery IS a Lithium-ion Battery System Designed to - CSH2
In stock · Ships same business day$3,890.00 $2,592.99 Save $1,297.01 -
APC by Schneider Electric
SKU: SUA031
APC Smart-ups Hardwire KIT for 2200/3000/5000VA SUA Models 120/208/230V - SUA031
In stock · Ships same business day$488.00 $326.99 Save $161.01 -
APC by Schneider Electric
SKU: SRYLFSU7
APC Smart-ups High Density Modular I/o Wiring Tray 200/208V - SRYLFSU7
In stock · Ships same business day$1,090.00 $737.99 Save $352.01 -
APC by Schneider Electric
SKU: SMTL1000RM2UC
APC Smart-ups Line Interactive 1000VA Lithium-ion Rackmount 2U 120V 6X NEM - SMTL1000RM2UC
In stock · Ships same business day$2,885.00 $1,632.99 Save $1,252.01 -
APC by Schneider Electric
SKU: SMTL1500RM3UC
APC Smart-ups Line Interactive 1500VA Lithium-ion Rackmount 3U 120V 6X NEM - SMTL1500RM3UC
In stock · Ships same business day$3,505.00 $1,867.99 Save $1,637.01
UPS & Power Management
Uninterruptible power supplies and rack-mount power distribution for network and surveillance infrastructure. Online and line-interactive UPS models with SNMP management protect against outages and power quality issues.
Plan Your Deployment
- Calculate total VA/watt load from all connected networking and recording equipment
- Specify required battery runtime for graceful shutdown or ride-through
- Evaluate online vs. line-interactive topology for power quality needs
- Confirm rack-mount form factor and outlet count for your cabinet
UPS & Power Management — Engineering-Grade UPS & Power Management for Commercial Deployments
This category covers 4 working models of ups & power management sourced manufacturer-direct or through channel-direct US distribution. Build the rest of your system around the architectural choices below — compatibility, environmental rating, and lifecycle decisions made here propagate through every downstream component you specify.
What to Look For
UPS topology dictates power quality during normal operation and transfer behavior during failure. Standby (offline) units switch to battery on AC failure — cheapest, with brief transfer time acceptable for cameras and switches. Line-interactive units regulate voltage and absorb sags without going to battery, extending battery life. Double-conversion online UPS deliver clean, constantly-regenerated AC — required for sensitive analytical equipment and ideal for critical NVRs.
Runtime is a function of load (watts) and battery capacity (Wh). A 1000VA UPS at 500W load runs 5-8 minutes on internal batteries — enough for graceful shutdown but not extended operation. Extended battery packs add hours. Calculate actual runtime requirement based on average utility outage duration in your area and the device's recovery behavior on power restoration.
Form factor and outlet count drive rack-vs-tower choice and circuit-breaker sizing. Tower UPSs serve standalone NVRs or desktop workstations. 1U-4U rack UPSs serve data closets and rack-mounted equipment. Look at the input plug type (NEMA 5-15, L5-30, L6-30) and confirm the building circuit supports the UPS rating; over-large UPSs on under-sized circuits trip breakers during charging.
Network management cards (APC AP9640, Eaton X-Slot) provide SNMP monitoring, email alerts, and integration with VMS or facility management software. For critical sites, this is essential — silent UPS failure leaves you blind until the next outage exposes it. Schedule annual self-tests through the management interface and replace batteries every 3-5 years as a preventive measure.
Key Specs in This Category
| Spec | Available Options |
|---|---|
| IP Rating | IP20 |
| Connectivity | Wired |
| Power | AC/DC, PoE |
| Type | Power Supply |
Top Brands in This Category
Frequently Asked Questions
What size UPS do I need for an 8-camera NVR?
For an 8-camera NVR drawing about 100-150W and a small PoE switch at 200W, plan for a 1000-1500VA UPS to support 15-30 minutes of runtime. That covers most utility outages and gives ample time for graceful shutdown if power doesn't return. For sites with frequent or extended outages, scale to 2000VA+ with an extended battery pack.
How long does a UPS battery last?
Sealed lead-acid (SLA) UPS batteries typically last 3-5 years. Lithium-ion UPS batteries (newer, more expensive) last 8-10 years. Heat is the primary aging factor — UPSs in unconditioned closets fail batteries faster. Schedule replacement at year 3 for SLA and year 7 for lithium, regardless of self-test results; runtime degrades silently and slowly before complete failure.
Should I use a UPS or a generator for backup power?
UPSs cover seconds-to-minutes outages and bridge to generator startup. Generators cover hours-to-days outages but take 10-30 seconds to come online. For sites that need uninterrupted operation through extended outages, both are required: UPS bridges the generator startup gap and conditions generator power, generator covers the long tail. Standalone UPS without generator works for most commercial sites where occasional brief outages are acceptable.
Can one UPS power my entire camera system?
For small sites (8-16 cameras, single NVR, one switch) — yes, a single UPS works. For larger sites, distribute UPS protection across multiple smaller units rather than one large UPS. Reasons: failure isolation (one UPS battery failure doesn't take down everything), shorter cable runs from UPS to load (avoids voltage drop), and runtime calculation simplicity per zone.
What's the difference between line-interactive and online UPS?
Line-interactive UPSs run on utility power normally and switch to battery on failure. They include voltage regulation (AVR) that absorbs sags and surges without battery use. Online (double-conversion) UPSs continuously regenerate AC from battery-rectified DC — perfect output regardless of input quality. Online UPSs cost 2-3x more and are appropriate for highly sensitive loads (servers, lab equipment) or sites with very poor utility power.
Need help choosing? Talk to a Senior Specialist — direct line 877-277-7147 or request a quote.