Panduit PE2V CBL MGR 12IN Wide SGL EA
Dual-sided vertical cable manager from the Panduit PatchRunner 2 line — built for high-density structured cabling environments where cable routing
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Panduit PE2VSD12 is a heavy-duty, dual-sided vertical cable manager from the Panduit PatchRunner™ 2 Enhanced line — engineered for high-density data center and enterprise rack environments where cable organization directly affects both airflow and maintenance access. At 45U of managed capacity plus 15 additional vertical U of cable routing space, this unit handles the kind of cable volume that accumulates in fully-populated 48U cabinets without forcing technicians to disassemble the rack to trace a circuit. The PE2VSD12 ships partially pre-assembled to reduce on-site installation time — a practical consideration when you're commissioning multiple racks in parallel.
At 12 inches wide (304.8 mm) and 83.9 inches tall (2,131.1 mm), the PE2VSD12 is sized to mount between standard EIA 48 cm and 58 cm racks, fitting neatly into the inter-rack bay that most open-frame and enclosed rack layouts already designate for vertical cable management. The unit is finished in black and meets RoHS compliance standards.
The PE2VSD12 is designed for use with EIA-standard 48 cm and 58 cm depth racks. It installs in the inter-rack bay between adjacent cabinets in a row configuration, or as a standalone vertical manager on the end of a rack row. The dual-sided construction supports simultaneous front-of-rack and rear-of-rack cable management from a single unit, which reduces the number of components to procure and the number of attachment points to maintain. For data centers planning hot-aisle/cold-aisle containment, the PE2VSD12's structured routing keeps cables from bridging containment barriers — a detail that matters for thermal management performance. The unit is part of the broader Panduit PatchRunner 2 Enhanced ecosystem, which includes complementary horizontal managers and patching panels designed to work together in high-density structured cabling deployments. Refer to your rack manufacturer's inter-bay spacing specifications before ordering to confirm the 12-inch width fits your specific cabinet row layout.
Q: What rack types is the PE2VSD12 compatible with?
A: The PE2VSD12 is designed for use with EIA-standard racks in 48 cm and 58 cm depth configurations. It mounts in the inter-rack bay between adjacent cabinets in a row deployment.
Q: How tall is the PE2VSD12, and does the 45U rating reflect total height?
A: The unit measures 83.9 inches (2,131.1 mm) overall. The 45U designation reflects the primary patch management zone; the unit also provides 15 additional vertical U of cable routing space beyond that, for a total functional height exceeding standard 45U cabinets.
Q: Does the PE2VSD12 include a door?
A: Yes. The PE2VSD12 includes a full-length metal door with a double-hinge design and push-to-close latch, providing cable containment on the dual-sided manager without requiring separate hardware.
Q: Is the PE2VSD12 RoHS compliant?
A: Yes, the PE2VSD12 meets RoHS compliance standards, making it suitable for deployments with green procurement requirements in regulated industries.
Q: Does the PE2VSD12 arrive pre-assembled?
A: The unit ships partially pre-assembled to simplify on-site installation and reduce deployment time during rack builds.
Q: What is the width of the PE2VSD12?
A: The PE2VSD12 is 12 inches (304.8 mm) wide, designed to fit the inter-rack bay in standard EIA rack row configurations.

The PE2VSD12 addresses a specific pain point I see regularly in high-density structured cabling builds: vertical managers that run out of usable routing space before the rack is fully patched. Panduit's decision to add 15U of routing space beyond the 45U patch zone — giving you 83.9 inches of total managed height — is the spec that matters most in a fully-loaded cabinet row where patch cord slack has to go somewhere.
Technical Highlights:
Deployment Considerations:
The PE2VSD12 is the right call for enterprise data center builds and co-location deployments where 40U+ cabinets are fully patched on both front and rear faces — specifically when your structured cabling standard requires contained, auditable cable paths and you can't afford to compromise rack unit space on intermediate horizontal managers.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Panduit products? Shop the full Panduit catalog →