Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit F92EPLCLCSCM001 OS2 LC Duplex Plenum Fiber Optic Patch Cord 1M

Overview

The Panduit F92EPLCLCSCM001 is a 1-meter, 2-fiber OS1/OS2 single-mode patch cord from the Opti-Core™ line, terminated with LC duplex connectors on both ends and rated OFNP (plenum) for air-handling space installation. At 3.28 ft, this is a short-reach jumper purpose-built for patch panel to active equipment connections inside a telecommunications room or data closet — the length that keeps cable management clean when horizontal runs terminate within a rack or cabinet. If you are building or maintaining a fiber optic patch cord infrastructure in a commercial or enterprise environment, this cord handles the last-meter connection without requiring conduit or raceways in plenum-rated ceiling spaces.

Key Features

  • OS1/OS2 Single-Mode Fiber: Single-mode glass supports long-haul transmission at 1310nm and 1550nm wavelengths — the right choice when your backbone runs extend beyond 300 meters or when you need the lowest insertion loss across a structured cabling plant. Using this at the patch level ensures you are not introducing multimode glass into a single-mode link and creating a modal mismatch that would degrade signal quality.
  • LC Duplex on Both Ends: LC connectors are the dominant interface on SFP and SFP+ transceivers in switches, routers, and fiber channel HBAs. Duplex LC-to-LC means this cord mates directly to virtually any small-form-factor transceiver port without adapters — fewer connection points means fewer potential sources of insertion loss in the link budget.
  • OFNP Plenum Rating: The plenum (OFNP) jacket compound self-extinguishes and produces minimal smoke under fire conditions, meeting the NEC requirements for installation in air-handling plenum spaces without conduit. If your cable pathway runs through a dropped ceiling that doubles as a return-air plenum, this rating is not optional — a non-plenum cord in that space is a code violation regardless of how it performs optically.
  • 1-Meter (3.28 ft) Length: This is the patch panel to switch jumper length — long enough to dress cleanly through a cable manager, short enough to avoid coiling excess slack that traps heat and creates tripping hazards in tight rack environments. Have the right length in stock; forcing a 3M cord into a 1M run adds unnecessary bend radius risk.
  • Opti-Core™ Sub-Brand: Panduit's Opti-Core line is engineered to consistent insertion loss and return loss specifications across the assembly, not just the connector. For Panduit fiber optic assemblies, that means the cord is tested as a complete link, not just the ferrule, which matters in high-density installations where cumulative loss across dozens of patch points can degrade margin.
  • RoHS Compliant: Meets EU Restriction of Hazardous Substances requirements — relevant if the installation is destined for export, a government facility with environmental procurement requirements, or any project that requires documentation of restricted material compliance at the component level.
  • Green Cable Color: Color coding is a real operational tool. Green jackets on single-mode fiber are the TIA-568 standard color — any technician following the standard will immediately identify this as single-mode, reducing the risk of accidentally patching single-mode ports with multimode cords (which would appear to work at short distances but introduce significant loss).
  • Package Quantity of 1, Carton of 10: Available to purchase as a single cord for targeted replacements or in cartons of 10 for structured deployments. Ordering by the carton makes sense when pre-terminating a new patch field — consistent lot manufacturing reduces lot-to-lot insertion loss variation.

Integration & Compatibility

The F92EPLCLCSCM001 mates with any LC duplex port — SFP, SFP+, SFP28, and SFP56 transceivers all use LC duplex interfaces. It is compatible with OS1 and OS2 single-mode links, making it appropriate for both legacy 9/125 OS1 runs and modern ultra-low water peak OS2 infrastructure. Install this cord between LC-equipped fiber optic patch panels and active switching equipment or between two patch panels in a cross-connect configuration. The OFNP rating allows installation in NEC Article 800 plenum spaces without additional conduit. RoHS compliance supports deployment in regulated environments. Because both connector types are LC duplex, this is a symmetric cord — polarity is managed at the structured cabling level, not by asymmetric connectors. Confirm your link polarity scheme (TIA-568 Method A, B, or C) before ordering in quantity; a symmetric LC-LC cord is compatible with all three methods when the trunk and cassette polarity is set correctly.

What's in the Box

  • 1x Panduit Opti-Core F92EPLCLCSCM001 OS2 LC Duplex to LC Duplex Plenum Fiber Patch Cord, 1M, Green

Frequently Asked Questions

Q: Is the F92EPLCLCSCM001 suitable for installation in plenum air-handling spaces without conduit?

A: Yes. The F92EPLCLCSCM001 carries an OFNP (plenum) flammability rating, which meets NEC requirements for direct installation in air-handling plenum spaces without conduit. Do not substitute a non-plenum (OFNR or CM) cord in a plenum pathway — that is a code violation regardless of optical performance.

Q: Can this cord be used on both OS1 and OS2 single-mode links?

A: Yes. The fiber type is specified as OS1/OS2, meaning it is compatible with both legacy 9/125 OS1 infrastructure and modern OS2 ultra-low water peak runs. The optical characteristics are a superset — an OS2-spec fiber meets and exceeds OS1 attenuation requirements.

Q: What connector interface does the F92EPLCLCSCM001 use?

A: Both ends are terminated with LC duplex connectors. LC duplex is the standard interface on SFP, SFP+, SFP28, and SFP56 transceivers. No adapter is needed to connect directly to small-form-factor transceiver ports on switches, routers, or fiber channel HBAs.

Q: Is this cord RoHS compliant?

A: Yes. The F92EPLCLCSCM001 is listed as conforming to RoHS (Restriction of Hazardous Substances) requirements, making it appropriate for projects with environmental procurement documentation requirements or installations destined for regulated markets.

Q: Why is the cable green?

A: Green is the TIA-568 standard jacket color for single-mode fiber. Color coding allows technicians to immediately identify single-mode cords and avoid inadvertently patching them into multimode ports — a mismatch that would appear to link at short distances but introduce significant insertion loss. Using standard color conventions is an operational discipline, not cosmetic.

Q: How many fibers does the F92EPLCLCSCM001 contain?

A: Two fibers — one transmit and one receive — which is the standard count for a duplex LC-to-LC patch cord. This supports full-duplex operation on a single cord without the need for separate Tx and Rx jumpers.

Ted Perry
Ted Perry

The F92EPLCLCSCM001 is one of those cords that looks like a commodity until the job site inspector flags a non-plenum jumper running through a return-air ceiling — at that point the OFNP rating on this Panduit Opti-Core assembly is worth more than any cost savings from a generic cord. At 1 meter, this is specifically a within-rack or top-of-rack jumper: patch panel to switch, switch to media converter, or cassette to transceiver. The OS1/OS2 compatibility means you can deploy this on any single-mode backbone without checking fiber generation at the closet level.

Technical Highlights:

  • OFNP Plenum Rating: Allows direct installation in NEC plenum spaces — no conduit, no raceway required. This is a go/no-go requirement in commercial buildings with dropped-ceiling return-air systems, not a preference.
  • OS1/OS2 Dual Compatibility: A single SKU covers both legacy OS1 9/125 plants and current OS2 low-water-peak infrastructure. You do not need separate SKUs for mixed-generation fiber plants, which simplifies stocking for MACDs on enterprise campuses.
  • LC Duplex Both Ends: Direct compatibility with SFP/SFP+/SFP28 transceivers — the dominant interface in current enterprise switching. No adapters, no polarity sleeves, no conversion hardware adds insertion loss or failure points to the link.

Deployment Considerations:

  • At exactly 1 meter, confirm rack-unit spacing before ordering in volume — if your patch panel and switch are not on adjacent 1U shelves, you may need the next standard length to avoid forcing a tight bend radius at the connector boot.
  • The green jacket is TIA-568 single-mode standard, but confirm with your installation team that they are following the color convention — in a mixed-mode environment, a mis-identified cord patched into a multimode port will appear to link at short reach while silently degrading margin.

This cord is the right specification for enterprise IDF closets and MDF patch fields in commercial office, healthcare, or education facilities where plenum-rated pathways are the norm and SFP-based switching is the active layer — specifically where you need a documented, standards-compliant jumper that will pass both optical and fire inspection.

Specifications
Sub Brand: Opti-Core™
Color: Vert
Connector 1: LC Duplex
Connector 2: LC Duplex
Fiber Type: OS1/OS2
Flammability Rating: Plénum (OFNP)
Fiber Count: 2
Length Ft: 3.28
Length M: 1
Product Type: Fiber Optic Patch Cord
Carton Qty: 10
Package Qty: 1
Standards: Conforme RoHS
Upc: 61305686623
Cable Category: fiber-optic-systems
Q&A
Reviews
Have Questions?

Panduit OS22F 1.6 Pcofnp NK Lc/d Pols GR 1M PK1

$64.34
$41.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources