Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: F92RPU2U2ONM003
UPC: 613056810228
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 35% OFF

Panduit F92RPU2U2ONM003 OS2 LC Uniboot Patch Cord 3m

Panduit F92RPU2U2ONM003 Opti-Core OS2 Single-Mode LC Duplex Uniboot Fiber Patch Cord, 3 Meter The Panduit F92RPU2U2ONM003 is a 3-meter OS2 single-mode…

$71.90 $46.99 SAVE $25

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit F92RPU2U2ONM003 OS2 LC Uniboot Patch Cord 3m

$71.90
$46.99

Overview

SKU: F92RPU2U2ONM003
UPC: 613056810228
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit F92RPU2U2ONM003 Opti-Core OS2 Single-Mode LC Duplex Uniboot Fiber Patch Cord, 3 Meter

The Panduit F92RPU2U2ONM003 is a 3-meter OS2 single-mode fiber patch cord engineered for high-density datacenter and enterprise network deployments where insertion loss budgets, space constraints, and plenum compliance intersect. Built on Panduit's Opti-Core platform, this cable delivers duplex LC uniboot connectivity with APC (Angled Physical Contact) terminations on both ends, reducing return loss to <−60 dB and enabling 10G/40G/100G optics to operate within manufacturer-specified link budgets. The uniboot form factor consolidates two fibers into a single pull-boot assembly, cutting patch-panel port density requirements by half compared to traditional duplex LC designs and simplifying moves/adds/changes in congested horizontal managers. Yellow OFNP-rated jacketing meets NEC Article 770 for installation in air-handling plenums without conduit, a requirement in most commercial office and datacenter ceiling spaces. At 3 meters (9.84 feet), this length suits rack-to-rack interconnects in adjacent rows, ToR-to-EoR switch uplinks, and cassette-based structured cabling cross-connects where pre-terminated trunk assemblies terminate into LC modules.

Key Features

  • OS2 Single-Mode Fiber: 9/125 μm core/cladding diameter supports transmission distances up to 10 km at 10 Gbps, 40 km at 1 Gbps, with <0.4 dB/km attenuation at 1310 nm and <0.3 dB/km at 1550 nm
  • LC Duplex Uniboot APC Connectors: Angled Physical Contact (8° polish) on both ends minimizes back-reflection (<−60 dB return loss) for DWDM, CWDM, and analog video applications; duplex uniboot housing reduces patch-panel footprint by 50%
  • Optimized Insertion Loss: Factory-terminated and tested to ≤0.20 dB typical IL per TIA-568-C.3, preserving link budget headroom for multi-span enterprise backbones and 40G/100G SR4 breakout scenarios
  • Plenum-Rated OFNP Jacket: Yellow low-smoke zero-halogen (LSZH) outer jacket meets UL 910 (Steiner Tunnel) for installation in HVAC plenums, elevator shafts, and above-ceiling pathways without EMT conduit
  • Uniboot Pull-Boot Design: Integrated strain relief and push/pull tab; single-body connector allows polarity reversal in the field (A↔B) without re-termination, critical for TIA-568 polarity Method B cassette deployments
  • 3-Meter Length (9.84 ft): Ideal for rack-to-rack interconnects in 42U–48U open-frame racks spaced <8 feet apart, standard in hot-aisle/cold-aisle datacenter layouts and IDF/MDF cross-connects
  • RoHS Compliant: Meets Directive 2002/95/EC for lead-free, mercury-free, cadmium-free construction; required for federal GSA Schedule deployments and EU-regulated verticals
  • TIA/ISO Standards Conformance: Exceeds TIA-568-C.3, ISO/IEC 11801, TIA-604-3 (FOCIS-3 LC), TIA-604-10 (FOCIS-10 APC) for interoperability with Cisco, Arista, Juniper, Brocade, and Dell EMC SFP/SFP+/QSFP28 transceivers
  • Carton Quantity 10: Bulk packaging for large-scale datacenter builds, campus network refresh projects, and MSP staging inventory; reduces per-unit cost for projects requiring 50+ interconnects

OS2 Single-Mode Performance and APC Connector Geometry: OS2 fiber uses a 9 μm core diameter (vs. 50 μm or 62.5 μm in multimode designs), confining light to a single propagation mode and eliminating modal dispersion. This enables the F92RPU2U2ONM003 to support 10 Gbps links over 10 km (10GBASE-LR), 1 Gbps over 40 km (1000BASE-LX), and future 25G/50G/100G optics on the same physical infrastructure—critical for enterprises planning 5–10 year cabling lifecycles. The APC (Angled Physical Contact) endface geometry polishes the fiber ferrule at an 8° angle, directing Fresnel reflections into the cladding rather than back toward the source. This achieves <−60 dB return loss (vs. −40 dB for UPC connectors), a requirement for DWDM systems, CATV RF-over-fiber deployments, and any application where coherent detection or high-power lasers amplify the impact of back-reflection noise. Panduit's factory termination process uses automated polishing and interferometric inspection to guarantee ≤0.20 dB insertion loss per mated pair, well below the TIA-568-C.3 channel limit of 0.75 dB per connector. For a typical 2-connector permanent link (backbone switch to distribution switch), this leaves 0.35 dB of headroom for splice losses, bend radius attenuation, and aging—insurance against future optics that operate closer to receiver sensitivity floors.

Uniboot Design Advantages in High-Density Environments: Traditional duplex LC patch cords use two separate 1.6 mm or 2.0 mm zipcord legs joined by a clip, consuming ~12 mm of horizontal width per connection. The F92RPU2U2ONM003's uniboot housing merges both fibers into a single ~6 mm boot, cutting patch-panel real estate in half—transformative in 1U 96-port LC panels where every millimeter of bend radius and finger space matters. The integrated pull-boot tab allows one-handed insertion and extraction without pinching individual connectors, reducing install time and the risk of endface contamination from fingerprint oils. Polarity reversal is field-configurable: slide the release latch, rotate the duplex ferrule 180°, and re-seat—converting a Method A cable to Method B (or vice versa) in under 10 seconds. This eliminates the need to stock separate A-to-A and A-to-B cable SKUs for cassette-based systems, simplifying inventory and reducing on-site decision fatigue during cutovers. The yellow OFNP jacket uses a low-smoke PVC compound rated for continuous exposure to 60°C, with a minimum bend radius of 10× cable OD during installation (30 mm) and 5× OD when dressed (15 mm). In practice, the uniboot's rigid strain relief prevents kinking at the connector-cable transition—the failure point responsible for 40% of field attenuation spikes in traditional duplex designs.

Plenum Rating and Datacenter Installation Context: OFNP (Optical Fiber Nonconductive Plenum) jacketing meets UL 910 flame propagation and smoke density requirements, allowing this cable to run through HVAC return-air plenums, above-ceiling J-hooks, and vertical risers without metallic conduit. Most commercial office buildings and colocation facilities classify the space above drop ceilings as a plenum per NFPA 90A, making OFNP the minimum acceptable rating for horizontal fiber runs between IDFs, overhead cable trays in raised-floor datacenters, and campus backbone pathways in multi-story buildings. The 3-meter length is purpose-built for rack-adjacency scenarios: ToR (Top-of-Rack) switches connecting to EoR (End-of-Row) aggregation switches 6–8 feet away, storage-array controller ports cross-connecting to FC SAN switches in the next rack, or hyperconverged nodes forming a 10 GbE mesh in a 4-post open-frame layout. In cassette-based structured cabling architectures (Panduit's FZ, FHD, or FQHD systems), this patch cord serves as the equipment cord linking cassette LC ports to switch/server SFP+ transceivers, while 12-fiber or 24-fiber MTP backbone trunks handle inter-floor vertical distribution. The yellow jacket follows TIA-598-C color-coding for OS2 single-mode fiber, preventing accidental cross-connection with aqua OM3/OM4 multimode cables—a fault that causes immediate link failure and wastes hours of troubleshooting in mixed-mode plants.

Standards compliance locks this cable into enterprise procurement workflows: TIA-568-C.3 conformance is a line-item requirement in most corporate RFPs and university campus network builds, ensuring interoperability with any TIA-compliant cassette, patch panel, or enclosure. ISO/IEC 11801 alignment extends that guarantee to international projects (EMEA datacenters, APAC manufacturing campuses) where local regulations reference ISO rather than TIA specs. TIA-604-3 (FOCIS-3) and TIA-604-10 (FOCIS-10) define the physical dimensions and optical geometry of LC and APC connectors, respectively, guaranteeing this cable will mate with Cisco SFP-10G-LR, Arista SFP-10G-LRM, Juniper EX4300 optics, and any other standards-compliant transceiver without adapter loss or mechanical interference. RoHS compliance (Directive 2002/95/EC) removes lead, mercury, cadmium, and hexavalent chromium from all cable components, a federal-mandate checkbox for GSA Schedule 70 orders, DoD installations, and California Title 20 regulated environments. The 10-pack carton quantity aligns with datacenter staging workflows—installers can pre-position bundles at each row, reducing trips to the staging area and keeping pace with 20–30 rack/day deployment cadences during colo build-outs or hyperscale expansions.

Specifications
Product Type: Fiber Optic Patch Cord
Sub-Brand: Opti-Core®
Fiber Type: OS2 Single-Mode
Core/Cladding Diameter: 9/125 μm
Number of Fibers: 2
Connector 1 Type: LC Duplex Uniboot APC
Connector 2 Type: LC Duplex Uniboot APC
Cable Length: 3 m (9.84 ft)
Cable Color: Yellow
Jacket Rating: Plenum (OFNP)
Insertion Loss: ≤0.20 dB typical
Return Loss:
Polish Type: 8° Angled Physical Contact (APC)
Bend Radius (Install: 30 mm (10× cable OD)
Bend Radius (Dressed: 15 mm (5× cable OD)
Operating Temperature: -20°C to +60°C
Standards Compliance: TIA-568-C.3, ISO/IEC 11801, TIA-604-3 (FOCIS-3), TIA-604-10 (FOCIS-10)
RoHS Compliant: Yes (Directive 2002/95/EC)
UPC: 61305681022
Carton Quantity: 10
Package Quantity: 1
Type: Fiber Optic Patch Cord
Connectivity: LC Duplex Uniboot
Form Factor: Uniboot
Sub Brand: Opti-Core®
Connector 1: LC Duplex Uniboot APC
Connector 2: LC Duplex Uniboot APC
Flammability Rating: Plenum (OFNP)
Fiber Count: 2
Length Ft: 9.84
Length M: 3
Carton Qty: 10
Package Qty: 1
Standards: RoHS Compliant. Meets or exceeds ISO/IEC 11801, TIA/EIA-568-C.3, TIA-604-3 (FOCIS-3), TIA-604-10 (FOCIS-10), All patch cord components meet the requirements of Directive 2002/95/EC.
Cable Category: fiber-optic-systems
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources