Panduit F92RPU2U2ONM016 16m OS2 Uniboot LC Patch Cord

Panduit F92RPU2U2ONM016 Opti-Core 16m OS2 Single-Mode Fiber Patch Cord Datacenter and telecom installers face constant pressure to maximize rack densi…

$84.10 $53.99 SAVE $30

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit F92RPU2U2ONM016 16m OS2 Uniboot LC Patch Cord

$84.10
$53.99

Overview

SKU: F92RPU2U2ONM016
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit F92RPU2U2ONM016 Opti-Core 16m OS2 Single-Mode Fiber Patch Cord

Datacenter and telecom installers face constant pressure to maximize rack density while maintaining clean, manageable fiber infrastructure. The Panduit F92RPU2U2ONM016 Opti-Core fiber patch cord addresses both challenges with a duplex LC uniboot design that cuts panel congestion in half compared to traditional duplex LC connectors. At 16 meters (52.5 feet), this OS2 single-mode jumper hits the sweet spot for inter-rack connections in datacenter rows, equipment-to-distribution cross-connects in telecom rooms, and horizontal pathways between entrance facilities and MDF. The yellow OFNP plenum jacket keeps you code-compliant in raised-floor and overhead-plenum environments without the conduit overhead, while factory-terminated APC polish delivers the low return loss and insertion loss that 10G/40G/100G optics demand.

Key Features

  • Uniboot LC Duplex APC connectors — single-boot design with integrated pull-tab saves 50% panel space vs. two-connector duplex LC; field-reversible polarity without re-termination
  • OS2 9/125μm single-mode fiber — supports 10GBASE-LR, 40GBASE-LR4, 100GBASE-LR4, and future 400G optics over multi-kilometer distances; optimized insertion loss spec for low link budget penalty
  • 16-meter plenum-rated cable — OFNP jacket meets NEC 770.179 for air-handling spaces; yellow color-coding follows TIA-598-D single-mode convention; 2-fiber duplex construction
  • Factory-terminated APC polish — angled physical contact (8° endface) reduces return loss to -60 dB typical, eliminating back-reflection that degrades coherent optics and high-speed protocols
  • Opti-Core quality program — Panduit factory testing includes insertion loss, return loss, and endface geometry per IEC 61300-3-35; serialized test data available on request
  • Compliant with TIA-568-C.3, ISO/IEC 11801, TIA-604-10 (FOCIS-10) — meets commercial building cabling standards and connector interface specs; RoHS Directive 2002/95/EC compliant

The uniboot LC connector is the design detail that matters most in high-density fiber deployments. Traditional duplex LC patch cords use two separate connector bodies, each occupying one port on a fiber panel or switch faceplate. The Panduit Opti-Core uniboot merges both fibers into a single compact housing with a pull-tab for easy insertion and removal in tight spaces. This halves the footprint at the panel, letting you populate twice as many connections in the same rack unit—critical when you're trying to fit 96-port fiber panels into a 1U or 2U form factor. The uniboot design also simplifies polarity management: if you need to swap transmit and receive fibers (common when converting from straight-through to crossover topology), you flip a clip inside the boot rather than swapping two separate connectors at the panel. That means no downtime, no re-labeling, and no risk of mixing up the wrong pair in a bundle of 24 or 48 fibers.

APC (angled physical contact) polish is the standard for single-mode fiber in datacenter and carrier-grade applications, and this patch cord's 8-degree endface angle is the reason. When two fiber endfaces mate, any gap or imperfection reflects a portion of the optical signal back toward the transmitter—a phenomenon called return loss. Standard PC (physical contact) polish reflects roughly -40 dB of the signal back, which is acceptable for 1G and older multi-mode links but causes bit errors and signal degradation on 10G, 40G, and 100G coherent optics. APC polish angles the endface so that back-reflections exit the fiber core at an angle and dissipate into the cladding, achieving -60 dB return loss or better. That's a 100× reduction in reflected power, which keeps your link budget clean and your optics running within spec. The Panduit Opti-Core manufacturing process polishes and inspects every connector endface to IEC 61300-3-35 standards, with automated interferometry checking for scratches, pits, and geometry defects before the cord leaves the factory.

The 16-meter length is purpose-built for structured cabling topologies in mid-size datacenters and telecom facilities. You'll use this jumper to connect equipment racks within the same row (typical row depth is 12-20 meters when accounting for overhead cable tray routing), to cross-connect from horizontal fiber panels to active equipment in the same telecom room, or to bridge a main distribution frame (MDF) to an intermediate distribution frame (IDF) on the same floor. The OS2 fiber spec supports 10GBASE-LR out to 10 km, 40GBASE-LR4 to 10 km, and 100GBASE-LR4 to 10 km, so your 16-meter link budget is a rounding error—leaving you headroom for future optics upgrades, dirty connectors, and the inevitable splice or two in the permanent link. The yellow jacket follows TIA-598-D color conventions for single-mode fiber (multi-mode is orange or aqua), making it easy for your team to distinguish between fiber types during installs and troubleshooting. The OFNP plenum rating certifies the jacket's flame spread and smoke generation meet NEC Article 770 requirements for cables installed in air-handling spaces without conduit, which covers raised floors, drop ceilings, and HVAC plenums in 90% of commercial buildings.

Panduit manufactures these patch cords in ISO 9001-certified facilities and backs them with a comprehensive warranty covering materials, workmanship, and optical performance. The Opti-Core product line undergoes 100% factory testing for insertion loss (≤0.35 dB typical for LC connectors) and return loss (≥60 dB for APC), with test results stored in Panduit's quality database and retrievable by serial number if you need documentation for a client audit or warranty claim. The duplex LC uniboot connector meets TIA-604-10 (FOCIS-10) dimensional specs and mates with any standards-compliant LC adapter or transceiver, so you're not locked into Panduit-only infrastructure. The pull-boot design includes a strain-relief boot and pull-tab molded from impact-resistant polymer that survives hundreds of insertion cycles without cracking or delaminating—important when you're patching and re-patching circuits during MACs (moves, adds, changes) in a live datacenter. For integrators managing multi-building campuses or large-scale datacenter builds, Panduit offers these patch cords in carton quantities of 10, with consistent lead times and SKU availability through authorized distribution, so you can order the exact lengths you need without paying custom-termination premiums or waiting weeks for a build-to-order quote.

Specifications
Product Type: Fiber Optic Patch Cord
Sub-Brand: Opti-Core
Fiber Type: OS2 Single Mode
Fiber Diameter: 9/125 μm
Number of Fibers: 2
Cable Length: 16 m (52.49 ft)
Connector 1 Type: LC Duplex Uniboot APC
Connector 2 Type: LC Duplex Uniboot APC
Polish Type: APC (Angled Physical Contact)
Cable Color: Yellow
Jacket Rating: Plenum (OFNP)
Flammability Rating: OFNP per NEC 770.179
Insertion Loss: ≤0.35 dB typical
Return Loss: ≥60 dB (APC)
Standards Compliance: TIA-568-C.3, ISO/IEC 11801, TIA-604-3 (FOCIS-3), TIA-604-10 (FOCIS-10), RoHS 2002/95/EC
Application: Datacenter interconnects, telecom room cross-connects, entrance facility pathways, horizontal distribution
Package Quantity: 1
Carton Quantity: 10
UPC: 61305681148
Type: Fiber Optic Patch Cord
Connectivity: LC Duplex Uniboot APC
Form Factor: Uniboot
Sub Brand: Opti-Core®
Connector 1: LC Duplex Uniboot APC
Connector 2: LC Duplex Uniboot APC
Fiber Count: 2
Length Ft: 52.49
Length M: 16
Carton Qty: 10
Package Qty: 1
Standards: RoHS Compliant. Meets or exceeds ISO/IEC 11801, TIA/EIA-568-C.3, TIA-604-3 (FOCIS-3), TIA-604-10 (FOCIS-10), All patch cord components meet the requirements of Directive 2002/95/EC.
Cable Category: fiber-optic-systems
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources