Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: FW2ELQ1Q1NNM002
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 0% OFF

Panduit FW2ELQ1Q1NNM002 LC-LC SM Fiber Cable 2m

Panduit FW2ELQ1Q1NNM002 LC-LC Duplex Single-Mode Fiber Patch Cable, 2 Meter The Panduit FW2ELQ1Q1NNM002 is a 2-meter duplex single-mode fiber optic pa…

$77.26 $76.99 SAVE $0

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit FW2ELQ1Q1NNM002 LC-LC SM Fiber Cable 2m

$77.26
$76.99

Overview

SKU: FW2ELQ1Q1NNM002
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FW2ELQ1Q1NNM002 LC-LC Duplex Single-Mode Fiber Patch Cable, 2 Meter

The Panduit FW2ELQ1Q1NNM002 is a 2-meter duplex single-mode fiber optic patch cable terminated with LC connectors on both ends, engineered for high-bandwidth data center, enterprise network, and IP surveillance backbone applications. Built on OS2 9/125μm single-mode fiber, this cable delivers reliable 10/40/100 Gigabit Ethernet and Fibre Channel connectivity across building risers, campus links, and equipment-room patch fields where low insertion loss and long-term link stability are non-negotiable. The duplex LC form factor makes it the standard choice for SFP+/QSFP28 transceiver modules in switches, media converters, and fiber-fed NVR uplinks where bidirectional transmission requires two fibers in a compact footprint.

Key Features

  • OS2 9/125μm single-mode fiber — supports transmission distances up to 10 km at 10 Gb/s, up to 40 km at 1 Gb/s, enabling campus backbone and inter-building links without repeaters
  • Duplex LC (Lucent Connector) terminated both ends — industry-standard interface for SFP/SFP+/SFP28 transceiver modules in Cisco, Ubiquiti, Axis, Hanwha, and enterprise switch platforms
  • Precision-polished ferrules with IL ≤0.3 dB typical — ensures minimal signal attenuation and reliable link budget for high-speed protocols including 10GBASE-LR, 40GBASE-LR4, and 100GBASE-LR4
  • 2-meter factory-terminated length — eliminates field splicing and provides strain-relief routing within equipment racks, fiber panels, and wall-mount enclosures
  • UPC (Ultra Physical Contact) polish — prevents back-reflection that degrades Bit Error Rate in multi-gigabit and analog video transmission over fiber
  • TIA-568 and ISO/IEC 11801 compliant construction — meets structured cabling standards for permanent link and channel performance in commercial installations
  • Non-plenum PVC jacket (NNM designation) — suitable for equipment rooms, riser pathways with plenum-rated innerduct, and patch-cord applications where air-handling space is not directly exposed
  • Color-coded boots and aqua blue cable jacket — provides instant visual identification of single-mode fiber vs. multimode (orange) to prevent costly mis-patching during MACs

Panduit manufactures this cable assembly with 9/125μm OS2-grade single-mode fiber that exhibits chromatic dispersion of ≤18 ps/nm·km at 1550 nm and attenuation ≤0.4 dB/km across the C-band, enabling CWDM and DWDM wavelength multiplexing for high-density fiber networks. The duplex LC connector uses a 1.25 mm zirconia ceramic ferrule polished to an 8° angled physical contact (UPC) endface geometry, producing return loss ≥50 dB to suppress Fabry-Pérot resonance in Distributed Feedback (DFB) laser transceivers. Each ferrule is pre-loaded into a thermoplastic housing with integrated push-pull latch mechanism that mates with SFP cages per IEC 61754-20, delivering >500 insertion cycles without performance degradation. The cable body consists of dual 900μm tight-buffered fibers inside a flame-retardant PVC outer jacket rated for general-purpose indoor use; the NNM suffix confirms non-plenum construction, making this cable appropriate for equipment rooms, telecom closets, and enclosed raceways but requiring substitution with OFNP-rated assemblies when routed through ducted HVAC return-air spaces.

This 2-meter length is optimized for patch-panel-to-switch connections in equipment racks, fiber distribution frame (FDF) cross-connects, and short jumper applications where pre-terminated field-installable connectors would introduce unacceptable insertion loss or require specialized fusion-splicing tools. The duplex LC interface is the de facto standard for 10 Gb/s and faster Ethernet: 10GBASE-LR SFP+ modules (1310 nm, 10 km reach), 25GBASE-LR SFP28 (1310 nm, 10 km), 40GBASE-LR4 QSFP+ (4×10 Gb/s CWDM lanes, 10 km), and 100GBASE-LR4 QSFP28 (4×25 Gb/s CWDM lanes, 10 km) all use LC-duplex or dual-LC physical interfaces. In IP surveillance deployments, this cable links fiber-capable PoE switches (e.g., Cisco Catalyst 9300 with SFP+ uplinks, UniFi Dream Machine Pro with SFP+ WAN) to building-distribution or campus-core switches, allowing high-megapixel camera streams to aggregate over a lossless fiber backbone rather than copper uplinks constrained by 100-meter distance limits. Integrators installing Axis Q-line PTZ cameras with fiber SFP media converters, or Hanwha Wisenet X-series with SFP cages, rely on OS2 single-mode patch cables to bridge equipment rooms separated by 300+ meters without signal repeaters, eliminating lightning-induced ground loops common in copper runs across separate buildings.

The cable meets TIA-568.3-D and ISO/IEC 11801-1 specifications for OS2 single-mode channel performance, ensuring insertion loss ≤0.75 dB per mated connector pair when used with compliant adapters and cleaning protocols. UPC polish geometry is mandatory for data-grade applications; APC (Angled Physical Contact) 8° polish is reserved for RF-over-fiber and analog CATV where return loss >60 dB is required but is incompatible with UPC-equipped transceivers. Panduit includes individual dust caps on each LC connector to protect ferrule endfaces during storage and installation; field technicians must inspect and clean ferrules with lint-free wipes and 99.9% isopropyl alcohol before every mating cycle to prevent micro-scratches that elevate insertion loss beyond the 0.3 dB factory spec. This assembly ships with serialized test data confirming IL and RL performance per connector, providing audit-trail documentation for mission-critical data center and financial-services network builds where link budget validation is part of the acceptance process.

Specifications
Product Type: Fiber Optic Patch Cable
Connector Type A: LC Duplex
Connector Type B: LC Duplex
Fiber Mode: Single-Mode OS2
Fiber Core/Cladding: 9/125 μm
Cable Length: 2 Meters
Polish Type: UPC (Ultra Physical Contact)
Insertion Loss: ≤0.3 dB Typical
Return Loss: ≥50 dB
Jacket Material: PVC (Non-Plenum)
Jacket Color: Aqua Blue
Cable Rating: General Purpose Indoor (NNM)
Fiber Count: 2 (Duplex)
Buffer Type: 900 μm Tight Buffer
Connector Durability: >500 Mating Cycles
Standards Compliance: TIA-568.3-D, ISO/IEC 11801, IEC 61754-20
Operating Wavelength: 1310 nm / 1550 nm
Maximum Attenuation: ≤0.4 dB/km @ 1550 nm
Application: 10/40/100 Gigabit Ethernet, Fibre Channel, SFP/SFP+/QSFP Transceiver Interconnect
Type: Fiber Optic Cable
Connectivity: LC Duplex
Cable Category: fiber-optic-systems
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources