Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: FC2SA-12-10U
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 31% OFF

Panduit FC2SA-12-10U OM4+ 12-Fiber MPO-LC Cassette

Panduit FC2SA-12-10U OptiCom™ OM4+ 12-Fiber MPO-LC Cassette The Panduit FC2SA-12-10U is a factory-terminated fiber cassette engineered for high-densit…

$999.86 $690.99 SAVE $309

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit FC2SA-12-10U OM4+ 12-Fiber MPO-LC Cassette

$999.86
$690.99

Overview

SKU: FC2SA-12-10U
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FC2SA-12-10U OptiCom™ OM4+ 12-Fiber MPO-LC Cassette

The Panduit FC2SA-12-10U is a factory-terminated fiber cassette engineered for high-density data center and enterprise network deployments requiring 40G/100G backbone connectivity. This OptiCom™ system component houses 12 strands of OM4+ ultra-low loss multimode fiber in a pre-configured MPO-to-LC breakout format, eliminating field termination labor and the insertion-loss variability that comes with on-site splicing. The universal polarity method built into this cassette supports both straight-through and crossover trunk configurations without requiring adapter flipping or custom cable assemblies, a critical advantage when provisioning leaf-spine architectures or migrating between TIA polarity standards mid-deployment. At 12.62" × 9.9" × 10", the unit is sized for standard 1U fiber enclosures and accepts duplex LC connections on six ceramic-ferruled adapters, delivering the port density IT teams need when rack space is constrained and every RU counts.

Key Features

  • OM4+ ultra-low loss fiber — 2.0 dB/km maximum attenuation vs. 3.0 dB/km for standard OM4, extending 100GBASE-SR4 reach to 150m and 40GBASE-SR4 to 200m without active optics
  • Universal polarity method — supports Method A, B, or C trunk cables with a single cassette SKU, eliminating the need to stock polarity-specific variants
  • 12-fiber MPO-12 male input to six duplex LC outputs — maps to six bidirectional 10G/25G links or three 40G/100G parallel-optic channels
  • Zirconia ceramic ferrules on all LC adapters — industry-standard mating interface ensures <0.25 dB insertion loss and >1000 mating-cycle durability
  • Factory-terminated and tested — each cassette ships with insertion-loss test data, removing the uncertainty and rework risk of field terminations
  • Black housing — maintains visual organization in mixed-vendor enclosures; non-reflective finish reduces glare during maintenance
  • OptiCom™ system integration — pairs with Panduit FZ2 enclosures, cable management, and MPO trunk cables for a complete pre-engineered fiber infrastructure
  • 10-unit bulk pack — reduces per-port cost on large-scale rollouts and ensures consistent lot performance across a deployment zone

OM4+ fiber represents a measurable performance step beyond the OM4 standard most integrators spec by default. While both share the 50-micron core diameter and 850nm laser-optimization, OM4+ tightens the attenuation ceiling from 3.0 dB/km to 2.0 dB/km and raises the effective modal bandwidth from 4700 MHz·km to 6300 MHz·km. In practical terms, this means a 100GBASE-SR4 link that would hit its attenuation budget at 100 meters on OM4 can extend to 150 meters on OM4+ without requiring mode-conditioning patch cords or ER optics — a difference that matters when crossing campus quads, spanning warehouse aisles, or linking separate floors in a mid-rise colocation facility. The improved bandwidth also reduces inter-symbol interference on NRZ-encoded signals above 25 Gbps per lane, lowering bit-error rates and giving you margin against future 50G-PAM4 upgrades. For data center operators running 40G spine links today with an eye toward 100G or 400G in the next refresh cycle, OM4+ is the future-proof choice that doesn't cost materially more than legacy OM3 or OM4 installs.

The universal polarity design of the FC2SA-12-10U solves a persistent frustration in structured fiber deployments: matching cassette pinouts to trunk cable polarity. TIA-568 defines three polarity methods — Method A (straight key-up-to-key-down), Method B (key-up-to-key-up with one flip), and Method C (pairs flipped within the connector). In a traditional cassette system, you'd need to stock three different cassette SKUs to cover all three scenarios, or resort to field modifications like swapping adapter keys or re-pinning connectors. Panduit's universal cassette handles all three methods with a single part number by using an internal crossover layout that automatically corrects polarity regardless of which method your trunk cables follow. This is especially valuable in mixed-equipment environments — say, connecting Cisco fabric interconnects (typically Method B) to Dell storage arrays (often Method A) through the same fiber plant, or when inheriting an existing installation where the original polarity method is undocumented. You can swap trunk cables without touching the cassette, and add capacity to an existing enclosure without worrying whether the new modules will match the old ones. It's one less variable to track in your structured cabling documentation, and one less reason to dispatch a truck when a circuit goes down.

Installation labor is where pre-terminated cassettes deliver the most immediate ROI. Field-terminating a 12-fiber MPO connector requires a $15,000+ fusion splicer or a $3,000 mechanical splice tool, plus consumables (splice sleeves, cleaning supplies, heat-shrink boots) and the skill to consistently achieve <0.5 dB per splice across all twelve fibers. Even an experienced tech will need 45–90 minutes per cassette when you factor in cleaving, splicing, heat-shrinking, and test-and-troubleshoot time. A factory-terminated cassette like the FC2SA-12-10U reduces that to a 5-minute plug-in operation: route the MPO trunk cable into the enclosure, click the male MPO into the cassette's female port, insert the cassette into the panel, and land your six LC jumpers to the patch panel. Insertion loss is guaranteed by Panduit's factory certification (each cassette includes a test report with per-channel IL measurements), eliminating the post-install OTDR validation step that adds hours to a site acceptance test. On a 288-strand data center build-out — 24 cassettes across four enclosures — you're looking at two hours of plug-and-play installation versus two full days of field termination, and you've removed the single biggest source of fiber link failure (bad splices) from the equation. The labor cost delta alone typically pays for the cassette premium on any job larger than a single rack.

Operationally, the six-duplex-LC breakout format maps cleanly to common data center switch architectures. A single FC2SA-12-10U cassette can support six independent 10GBASE-SR or 25GBASE-SR server uplinks, three 40GBASE-SR4 spine connections (four fibers per link), or one 100GBASE-SR4 fabric link with two ports left for future expansion. When paired with a 24-port MPO enclosure like Panduit's FZ2U, you gain 144 usable LC ports in 1U of rack space — a 6:1 density improvement over traditional LC duplex panels. This density is critical in hyperscale colocation facilities where rack space leases by the RU and cross-connect fees scale with panel count, but it's equally valuable in enterprise server rooms where you're trying to fit 10G aggregation, 1G access, out-of-band management, and storage fabrics into a single 42U relay rack. The cassette-based approach also simplifies MAC (moves/adds/changes) work: swapping a failed server link is a patch-cord change at the LC side; re-homing a VLAN to a different switch is a trunk-side MPO swap. You're never cutting, splicing, or re-terminating under pressure during a maintenance window.

The FC2SA-12-10U ships in bulk packs of ten units, a packaging choice that aligns with how fiber is actually deployed in structured environments. Most rack-scale builds involve symmetrical port counts — eight spine switches each needing twelve uplinks, sixteen storage nodes each needing dual-port connectivity, etc. Buying in ten-packs ensures you have spares on hand for immediate replacements without stocking three different cassette types or waiting on distributor lead times, and it smooths out the per-port cost curve when you're bidding fixed-price cabling jobs. The zirconia ceramic ferrules used in the LC adapters are rated for a minimum of 1000 mating cycles per TIA-604-10-B, meaning these cassettes will outlast the switch hardware they're connecting — a meaningful durability threshold when you're patching and re-patching during beta testing, capacity expansions, or hardware refresh cycles. Ceramic also offers better thermal stability than polymer ferrules, maintaining <0.1 dB insertion-loss variation across the -40°C to +75°C range you'll encounter in unconditioned telecom huts or rooftop equipment enclosures.

This cassette integrates into Panduit's broader OptiCom™ ecosystem, which includes FZ-series enclosures, MCM cable management, and pre-terminated MPO trunk assemblies available in 8-fiber, 12-fiber, 24-fiber, and 72-fiber counts. Using components from a single system family ensures mechanical fit, polarity compatibility, and consistent color-coding across your horizontal and vertical fiber runs. It also simplifies procurement and vendor management — one PO, one warranty contact, one technical support line — compared to mixing cassettes from Vendor A, enclosures from Vendor B, and trunk cables from Vendor C and hoping the polarity pinouts align. For design-build contractors working under performance-bond requirements or government integrators facing Buy American Act compliance audits, a unified system with full traceability from factory to install site reduces documentation overhead and contractual risk. The FC2SA-12-10U carries standard Panduit manufacturer warranty and is backed by the same technical support team that assists with data center backbone designs, making it a defensible spec on jobs where the low bidder isn't automatically the winner.

Specifications
Product Type: Fiber Optic Cassette
Brand: Panduit
Sub-Brand: OptiCom™
MPN: FC2SA-12-10U
Fiber Type: OM4+ Multimode
Number of Fibers: 12
Fiber Core Diameter: 50 micron
Connector 1 Type: MPO-12 Male
Connector 2 Type: LC Duplex (6 ports)
Polarity Method: Universal (Method A/B/C compatible)
Ferrule Material: Zirconia Ceramic
Housing Color: Black
Overall Length: 12.62 in (320 mm)
Overall Width: 9.9 in (251 mm)
Overall Height: 10 in (254 mm)
Package Quantity: 1 cassette
Carton Quantity: 10 units
UPC: 613056567020
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources