Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: FRXTP77Y001F024
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 31% OFF

Panduit FRXTP77Y001F024 OM3 12-Fiber Plenum Trunk - 24ft

Panduit FRXTP77Y001F024 OM3 12-Fiber Plenum Trunk Cable Pre-terminated 12-fiber OM3 trunk assembly eliminates field termination labor and fusion-spli…

$655.10 $452.99 SAVE $202

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit FRXTP77Y001F024 OM3 12-Fiber Plenum Trunk - 24ft

$655.10
$452.99

Overview

SKU: FRXTP77Y001F024
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FRXTP77Y001F024 OM3 12-Fiber Plenum Trunk Cable

Pre-terminated 12-fiber OM3 trunk assembly eliminates field termination labor and fusion-splice costs while delivering factory-tested 10GBASE-SR/40GBASE-SR4/100GBASE-SR10 backbone capacity for datacenter horizontal runs, equipment interconnects, and riser applications. Plenum-rated OFNP jacket meets NEC Article 770.113(B) for installation in environmental air spaces above drop ceilings and below raised floors without conduit, simplifying compliance in telecommunications rooms, main distribution frames, and horizontal cross-connects where air-handling pathways are the only practical route.

Key Features

  • Factory-terminated 12-fiber trunk with MTP/MPO or LC connectors tested to <0.35 dB insertion loss per TIA-568.3-D
  • OM3 50/125µm laser-optimized multimode fiber delivers 10 Gb/s to 300m, 40 Gb/s to 100m, 100 Gb/s to 100m per IEEE 802.3ba
  • Plenum (OFNP) jacket rated for air-handling spaces per NEC 770.113(B) without conduit
  • 24-foot length suits typical rack-to-rack, floor-to-ceiling, or cross-connect applications in standard telecom room layouts
  • Opti-Core construction with aramid yarn strength members and bend-radius protection for 20+ year installed life
  • Polarity method B (TIA-568.0-D standard) ensures straight-through duplex channel operation without adapter flips

Rapid Deployment Architecture: Pre-terminated trunk assemblies cut installation time by 70% compared to field fusion splicing while eliminating the test-and-rework cycle that adds days to traditional fiber builds. Each connector is factory-polished, insertion-loss tested, and serialized for traceability—critical when deploying 40G/100G links where a single marginal splice kills the entire channel. The 12-fiber count matches common switch-port breakout scenarios: one trunk supports six duplex 10G links, three duplex 40G channels, or a single 100GBASE-SR10 parallel optics deployment. Integrators working under compressed schedules—datacenter cutovers, after-hours equipment moves, emergency link restorations—gain predictable installation windows without the splice van, fusion machine calibration, or OTDR post-test that field termination demands.

Plenum Compliance and Air-Space Routing: OFNP flammability rating qualifies this trunk for installation in ducts, plenums, and other environmental air spaces without additional conduit or raceway protection, per NEC Article 770.113(B). This matters in retrofit scenarios where existing cable trays run above drop ceilings or below raised floors—the primary air-return path in most commercial HVAC designs. Non-plenum cable in these zones fails inspection and triggers costly re-pulls; plenum-rated assemblies pass on first review. The jacket compound limits flame spread and smoke generation to levels safe for occupied buildings, meeting UL 910 (Steiner Tunnel) test criteria. For integrators working in healthcare, finance, or government facilities where fire marshal sign-off is mandatory before occupancy, factory certification and third-party ETL/UL marking remove ambiguity from the approval process.

OM3 Bandwidth and Migration Headroom: Laser-optimized 50/125µm OM3 fiber delivers 2000 MHz·km effective modal bandwidth at 850 nm—sufficient for 10GBASE-SR to 300 meters, 40GBASE-SR4 to 100 meters, and 100GBASE-SR10 to 100 meters per IEEE 802.3 and TIA-568.3-D distance specifications. This headroom supports in-place upgrades: today's 10G switch deployment can migrate to 40G or 100G optics without re-cabling, protecting the installed fiber investment across multiple hardware refresh cycles. The 12-fiber count future-proofs designs where initial deployment uses six duplex 10G links but planned expansion requires 40G aggregation or spine-leaf 100G uplinks. OM3 also offers lower transceiver cost than singlemode at these distances—850 nm VCSELs are $50–$150 cheaper per port than 1310 nm DFB lasers—making it the cost-effective choice for horizontal datacenter runs under 300 meters.

Designed for data centers, telecommunications rooms, entrance facilities, and equipment distribution areas requiring pre-terminated fiber infrastructure for rapid deployment. TIA-568.3-D, ISO/IEC 11801, and ANSI/TIA-942-B compliant. Panduit Opti-Core assemblies carry a factory warranty covering fiber performance and mechanical integrity—critical assurance when a single bad trunk can idle an entire switch fabric during troubleshooting.

Specifications
Product Type: Fiber Optic Trunk Assembly
Fiber Type: OM3 Multimode (50/125µm)
Fiber Count: 12
Overall Length (ft: 24
Overall Length (m: 7.3
Flammability Rating: Plenum (OFNP)
Standards Compliance: TIA-568.3-D, ISO/IEC 11801, ANSI/TIA-942-B
Bandwidth (MHz·km at 850nm: 2000
Max Distance 10GBASE-SR: 300m
Max Distance 40GBASE-SR4: 100m
Max Distance 100GBASE-SR10: 100m
Insertion Loss (max:
Jacket Material: OFNP Plenum-Rated
Polarity Method: Method B (TIA-568.0-D)
Application: Data centers, telecommunications rooms, entrance facilities
Sub-Brand: Opti-Core®
NEC Article: 770.113(B) Compliant
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources