Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: AR732507
UPC: 731304302438
Condition: New
Write a Review 45% OFF

APC by Schneider Electric Netshelter SV 48U 1200MM Deep - AR732507

APC by Schneider Electric AR732507 NetShelter SV 48U 1200mm Deep Rack EnclosureOverviewThe APC by Schneider Electric AR732507 is a 48U, 1200mm-deep op…

$511.00 $282.99 SAVE $228
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric Netshelter SV 48U 1200MM Deep - AR732507

$511.00
$282.99

Overview

SKU: AR732507
UPC: 731304302438
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric AR732507 NetShelter SV 48U 1200mm Deep Rack Enclosure

Overview

The APC by Schneider Electric AR732507 is a 48U, 1200mm-deep open-frame rack enclosure from the NetShelter SV line — a workhorse cabinet format built for data centers, server rooms, and network closets where you need a structured, high-density mounting solution for servers, patch panels, PDUs, and network gear. At 84.80 inches tall (215.4 cm), it accommodates a full 48U of rack-mountable equipment without consuming additional vertical real estate beyond a standard floor-to-ceiling bay. The 1200mm depth is the specification to pay attention to: it provides adequate clearance for deep 2-post and 4-post rack gear, including high-density blade chassis and deep 1U/2U servers that would be cramped or unsupported in a shallow 800mm or 1000mm cabinet.

Key Features

  • 48U Capacity: 48 rack units in a single enclosure means you can consolidate a full server stack, top-of-rack switching, patch infrastructure, and power distribution into one structured bay — reducing floor footprint and simplifying cable management compared to distributing gear across multiple shorter cabinets.
  • 1200mm Depth: The extended 1200mm depth accommodates the longest rack-mount chassis on the market, including deep UPS units, blade enclosures, and high-density storage arrays that routinely exceed 900mm in length. If your gear list includes any equipment over 800mm, this depth clears the spec without modification.
  • 84.80-Inch Standing Height (215.4 cm): The enclosure stands at 84.80 inches — designed to sit on a raised floor or standard data center slab and align with adjacent cabinets in a hot/cold aisle row. Verify ceiling clearance before deployment, especially in older IDF closets with drop ceilings.
  • 42.2 lb Empty Weight (19.14 kg): At 42.2 lb unloaded, the AR732507 is manageable for a two-person installation team without mechanical lifting equipment — a practical consideration when deploying into upper-floor server rooms or spaces without freight elevator access.
  • Non-Rack-Mountable (Floor-Standing) Design: This is a floor-standing enclosure, not a wall-mount or rack-within-rack unit. Plan your installation layout accordingly — it requires a stable, level floor surface and adequate aisle clearance front and rear for equipment service access.
  • Black Finish: Standard black finish integrates cleanly into mixed-vendor data center rows alongside other NetShelter SV, NetShelter SX, or third-party cabinet deployments without visual inconsistency.

Integration & Compatibility

The AR732507 is part of the APC by Schneider Electric NetShelter SV family, which is designed to accept APC's own rack PDUs, cable management accessories, blanking panels, and side panels as add-ons. Standard 19-inch EIA-310 rack equipment from any vendor mounts directly. If you are building out a structured rack infrastructure with power distribution and cooling, pair this enclosure with a compatible APC UPS sized to your load — the 1200mm depth leaves room for rear-mounted vertical PDUs without compromising equipment depth. Confirm compatibility of specific rail kits and cable management arms with APC's rack accessory selector before ordering, as SV and SX rail systems differ.

Frequently Asked Questions

Q: How tall is the AR732507 assembled?

A: The AR732507 stands 84.80 inches (215.4 cm) tall when assembled. Shipping height is 88.62 inches (225.1 cm) including packaging.

Q: What is the depth of the AR732507 and what equipment will it fit?

A: The AR732507 has a 1200mm usable depth. This accommodates most deep rack-mount servers, blade chassis, UPS units, and storage arrays, including equipment that exceeds 800mm or 1000mm in length.

Q: Can the AR732507 be wall-mounted?

A: No. The AR732507 is specified as not rack-mountable and is designed as a floor-standing enclosure only. It requires a level floor installation with adequate front and rear aisle clearance.

Q: How much does the AR732507 weigh empty?

A: The AR732507 weighs 42.20 lb (19.14 kg) empty. Shipping weight is 57.10 lb (25.9 kg) including packaging materials.

Q: Is the AR732507 compatible with standard 19-inch rack equipment?

A: Yes. The NetShelter SV enclosure accepts standard 19-inch EIA-310 rack-mount equipment. APC rail kits and accessories for the SV family mount directly; verify SV-specific rail compatibility before ordering third-party rails.

Marty Allison
Marty Allison

The AR732507 is the cabinet you reach for when depth is the binding constraint on your rack build. At 1200mm deep and 48U tall, it handles the gear that a standard 1000mm cabinet turns away — and at 42.2 lb empty, a two-person crew can position it without a lift.

Technical Highlights:

  • 1200mm Depth: Provides clearance for the longest rack chassis in production today — deep UPS units, full-depth blade enclosures, and 1U servers with rear cable management arms that routinely push past 1000mm.
  • 48U Capacity: A full 48 rack units lets you stack a complete server, switching, and power tier in one footprint — critical when floor space is metered in a colocation bay or compact data room.
  • 84.80-Inch Standing Height: Aligns with standard data center row heights for hot/cold aisle containment deployments; verify ceiling clearance to 225.1 inches shipping height before moving through doorways.

Deployment Considerations:

  • Floor-standing only — no wall-mount or overhead-mount option. Confirm your room layout allows front and rear service access before finalizing the installation position.
  • The 1200mm depth is an advantage for deep gear but requires a correspondingly deep aisle; standard 24-inch aisles may be tight with the cabinet doors open and a technician working inside.

The AR732507 is the right call for dense server room builds and colocation deployments where deep chassis gear is the norm — not a general-purpose shallow-depth wiring closet cabinet.

Specifications
Product Or Component Type: Enclosure
Color: Black
Dimensions: 84.80 in (215.4 cm)
Weight: 42.20 lb(US) (19.14 kg)
Mounting Mode: Not rack-mountable
Package 1 Height: 88.62 in (225.1 cm)
Package 1 Width: 4.69 in (11.9 cm)
Package 1 Length: 38.07 in (96.7 cm)
Package 1 Weight: 57.10 lb(US) (25.9 kg)
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources