APC by Schneider Electric AR3357WX930 48U Enclosure
48U NetShelter SX enclosure designed for enterprise data centers and network closets requiring robust physical security and thermal management for IT
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The AR3307 is a 48U NetShelter SX enclosure designed for high-density IT and security infrastructure deployments where physical capacity, cable management headroom, and long-term serviceability matter. At 600mm wide and 1200mm deep (usable depth 47.2"), this cabinet handles the full stack of modern equipment — deep 1U servers, UPS units, patch panels, and network switches — without the compromises you get from shallower alternatives. If you're building out a purpose-built security operations room, a secondary data center closet, or a structured wiring room for a large campus, the AR3307 is sized to grow with the deployment rather than cap it.
The enclosure ships in black with EIA-310-D compliance, meaning your standard 19-inch rack-mount equipment installs directly with no adapter gymnastics. Mounting depth adjusts from 7.52 inches (191mm) minimum to 41.73 inches (1060mm) maximum — a range that accommodates everything from thin patch panels to full-depth 1U blade chassis without repositioning the rail set.
The AR3307 integrates with the full APC by Schneider Electric ecosystem — NetShelter SX blanking panels, cable management arms, side-channel cable managers, vertical PDU brackets, and roof/floor gland plates all mount without modification. Third-party PDUs, patch panels, and KVM drawers sized to the EIA-310-D standard install identically. If you're specifying rack enclosures for a standardized deployment across multiple sites, the SX line offers consistent dimensions and accessory compatibility across the family, simplifying spare parts and tooling.
For airflow management, the perforated door and 1200mm depth support both front-to-rear and bottom-to-top airflow configurations. Pair with blanking panels in unused rack units to prevent hot-air recirculation — a detail that matters more in high-density builds than in lightly loaded cabinets.
Q: What is the maximum equipment depth the AR3307 can accommodate?
A: The AR3307 provides 47.2 inches (1199mm) of usable internal depth, with mounting rail positions adjustable from 7.52 inches (191mm) to 41.73 inches (1060mm) from the front of the cabinet. This covers virtually all standard 1U rack-mount servers, UPS units, and deep storage appliances without modification.
Q: How much weight can the AR3307 hold?
A: The AR3307 has a static load capacity of 3,000 lbs (1,363 kg) — meaning fully loaded and stationary. The dynamic load rating is 2,250 lbs (1,022 kg), which applies when the enclosure is being moved. For typical IT and security infrastructure builds, neither limit is a practical constraint.
Q: Does the AR3307 include side panels?
A: Yes. The AR3307 ships with lift-off side panels included. They remove completely (no hinge) for installation access and can be replaced once cabling is complete.
Q: Is the AR3307 compatible with standard 19-inch rack-mount equipment?
A: Yes. The AR3307 complies with EIA-310-D, which defines the standard 19-inch rack-mount hole pattern. Standard cage nuts, rack screws, and slide rail kits work without adapters.
Q: What door type does the AR3307 use?
A: The AR3307 uses a perforated split front door with a locking handle. The perforation supports airflow, and the split design allows partial opening in tight aisle configurations.
Q: Is the AR3307 part of APC's NetShelter SX line, and does that affect accessory compatibility?
A: Yes, the AR3307 is a NetShelter SX enclosure. This means it is compatible with the full NetShelter SX accessory family — including blanking panels, side cable managers, PDU brackets, and roof/floor gland kits — without custom adapters.

I spec the AR3307 when a project needs consolidation capacity without compromising on serviceability. The 3,000 lb static load rating and 47.2-inch usable depth mean this cabinet can absorb a fully loaded NVR stack, a pair of PoE switches, a UPS module, and a full patch bay in one footprint — and still have rail adjustment range left over. If your equipment list is still evolving at bid time, that 7.52-to-41.73-inch mounting depth window is meaningful insurance.
Technical Highlights:
Deployment Considerations:
The AR3307 is the right call for a purpose-built security operations room or a campus IDF closet where 48U of consolidated, deep-rack capacity needs to outlast two or three equipment refresh cycles without the cabinet becoming the constraint.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more APC by Schneider Electric products? Shop the full APC by Schneider Electric catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price