APC by Schneider Electric
SKU: G35T15KH4B4S
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APC by Schneider Electric G35TBXR6B6 is an extended run battery enclosure designed for the Galaxy 3500 UPS series, supporting 3-phase installations in the 10 to 40 kVA range. If your facility runs critical loads — data center racks, security infrastructure, industrial control systems — where standard runtime falls short during extended outages, this enclosure pairs with a compatible Galaxy 3500 UPS frame to add the battery capacity needed to bridge the gap. The integrated Molded Case Circuit Breaker (MCCB) provides overcurrent protection at the enclosure level, simplifying wiring and reducing the need for external panel components in your electrical design.
The G35TBXR6B6 ships in a gray steel enclosure measuring 59.02 H x 20.59 W x 36.42 D inches — a floor-standing form factor sized for data center rows or dedicated electrical rooms where a full-height battery cabinet is the standard deployment. Its gray color family coordinates with the broader Galaxy 3500 product line for a consistent equipment bay appearance.
The G35TBXR6B6 is designed exclusively for the APC by Schneider Electric Galaxy 3500 series UPS platforms operating in the 10 to 40 kVA range. Integration requires matching the UPS frame's input voltage — 208V (North American 3-phase delta or wye) or 400V (international IEC distribution) — to this enclosure's rated input. Consult the Galaxy 3500 UPS installation guide for battery extension cabling specifications and the maximum number of extended run enclosures supported per UPS frame.
For facilities planning full power continuity infrastructure, this enclosure works alongside UPS and power supply systems as part of a layered power protection strategy. Integrators managing large-scale deployments should also review power distribution options to ensure upstream panel capacity supports the combined load of the UPS frame plus battery extension. Facility engineers unfamiliar with 3-phase battery extension design should consult APC's Galaxy 3500 configuration documentation for proper battery string sizing and runtime calculations — runtime depends on load percentage and the number of battery enclosures deployed, not just the enclosure's kVA rating.
For security and surveillance integrators, extended runtime UPS infrastructure like the G35TBXR6B6 is a foundational element of NVR and recording infrastructure continuity planning — ensuring recording systems stay online through grid interruptions. Pair with appropriate PoE switch UPS feeds to extend protection down to the edge camera layer.
Q: What UPS models is the G35TBXR6B6 compatible with?
A: The G35TBXR6B6 is designed for the APC Galaxy 3500 series UPS platforms in the 10 to 40 kVA range. It is not designed for use with other APC UPS families or third-party UPS systems.
Q: What input voltages does the G35TBXR6B6 support?
A: The enclosure supports 208V and 400V input, covering North American 3-phase and international IEC-standard 3-phase distribution environments.
Q: What is the kVA range supported by the G35TBXR6B6?
A: It is rated for Galaxy 3500 UPS frames configured from 10 kVA up to 40 kVA.
Q: Does the G35TBXR6B6 include overcurrent protection?
A: Yes. The enclosure integrates a Molded Case Circuit Breaker (MCCB), providing overcurrent protection at the battery cabinet level without requiring a separate external breaker for the battery extension circuit.
Q: What are the physical dimensions of the G35TBXR6B6?
A: The enclosure measures 59.02 inches high x 20.59 inches wide x 36.42 inches deep and is a floor-standing gray steel cabinet.
Q: How much additional runtime does the G35TBXR6B6 provide?
A: Runtime extension depends on the connected load (as a percentage of UPS capacity) and the total number of battery enclosures deployed. APC's Galaxy 3500 runtime sizing tool and configuration documentation should be used to calculate expected runtime for a specific load profile.

The G35TBXR6B6 is a battery extension cabinet, not a UPS — that distinction matters more than it sounds. When I spec extended run infrastructure for a Galaxy 3500 deployment, the first question is always load percentage: at 40 kVA frame capacity with a 50% load, you're adding meaningfully more runtime per enclosure than at 90% load. The 10 to 40 kVA compatibility range on this enclosure means it stays valid across a site's capacity lifecycle, which justifies the procurement even if the frame starts at a lower kVA today.
Technical Highlights:
Deployment Considerations:
The G35TBXR6B6 is the right call for data centers and critical facility electrical rooms running Galaxy 3500 frames where a grid outage lasting beyond standard battery runtime is a genuine operational risk — think co-location facilities with SLA-backed uptime commitments or industrial control environments where a cold restart costs more than the cabinet.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more APC by Schneider Electric products? Shop the full APC by Schneider Electric catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price