Overview
Panduit LPCA08-X Dual-Lock IEC Cord 6ft Blue 10pk
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Bundle Summary
Overview
No Bots, Just Experts
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Panduit LPCA08-X Dual-Locking IEC Power Cord
The Panduit LPCA08-X delivers secure, accidental-disconnect-proof power distribution for rack-mounted equipment. This 10-pack of 6-foot IEC C14 to C13 cords features dual mechanical locks at the C13 receptacle end, preventing inadvertent power loss during maintenance, cable management, or routine data center operations. Blue PVC jacket enables color-coded power identification in mixed-vendor or multi-circuit racks. Rated for high-temperature environments and backed by UL, CE, and EAC approvals for global deployment compliance. SmartZone sub-brand positions this cord within Panduit's intelligent rack infrastructure ecosystem.
Key Features
- Dual-locking C13 connector mechanically secures to equipment inlet, preventing accidental pull-out during rack access or cable routing
- 10-pack configuration for full-rack or multi-rack deployments, reducing per-cord cost for infrastructure builds
- Blue PVC jacket for visual circuit identification—ideal for color-coded A/B power feeds or segregated PDU circuits
- 6-foot (1.8m) length suits typical rack-to-rack spacing or in-rack vertical PDU-to-device runs without excess slack
- High-temperature rating and high-conductivity copper for sustained load in densely populated server environments
- UL, CE, and EAC certifications for North American, European, and Eurasian Economic Union installations
Datacenter and server-room power distribution demands both reliability and manageability. The LPCA08-X addresses the core failure mode of standard IEC cords—unintentional disconnection—through Panduit's dual-lock design. Each C13 end incorporates two spring-loaded tabs that engage the equipment inlet's retention slots, creating a positive mechanical lock. This prevents pull-out from accidental tugs during adjacent equipment service, cable adds, or routine cleaning. The lock disengages only through deliberate depression of both release tabs, ensuring power stays connected unless an operator explicitly intends to disconnect. In practice, this eliminates the nuisance outages caused by cleaners, junior techs routing nearby cables, or vibration from high-airflow cooling systems gradually working standard friction-fit connectors loose.
The 10-pack format aligns with typical rack deployment quantities. A standard 42U rack with dual-corded 1U servers requires 84 cords; this pack covers one-eighth of that build, streamlining procurement and inventory. The blue jacket integrates into color-coded power schemes—common practice in facilities running redundant A/B feeds from separate PDUs or UPS branches. Assign blue to Feed A, another color to Feed B, and technicians can instantly verify load balance or diagnose single-feed failures without tracing cables end-to-end. The 6-foot length matches most rack configurations: vertical PDU mount to server inlet typically spans 2-4 feet; rack-to-rack horizontal runs in adjacent rows stay under 6 feet. This minimizes cable slack that clutters airflow paths or creates snag hazards, while still offering enough service loop for equipment removal or maintenance repositioning.
High-conductivity copper construction handles sustained loads without voltage drop or heat buildup—critical when powering blade servers, high-density switches, or GPU compute nodes that pull maximum rated current continuously. The high-temperature PVC insulation withstands the sustained heat loads typical of enclosed racks running at 70-80% capacity, where ambient temperatures inside the cabinet can reach 35-40°C even with adequate front-to-back airflow. Standard-grade cords in these environments show premature jacket degradation; the LPCA08-X's rating extends service life and maintains safety margins. Panduit's SmartZone portfolio focuses on intelligent power distribution and monitoring; while the LPCA08-X is a passive cable, it integrates with SmartZone PDUs and rack infrastructure for unified cable management and reliable connectivity across the power chain, supporting the structured approach required for ISO/IEC 27001 datacenter audits or SSAE 18 compliance reviews.
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Bundle Summary
Looking for more Panduit products? Shop the full Panduit catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology