Lifesafety Power FPO75-B100C8D8E4M1 75W power supply 6A/12V or 3

Lifesafety Power FPO75-B100C8D8E4M1 75W Power Supply with Multi-Output Control ModuleOverviewThe FPO75-B100C8D8E4M1 is a 75W industrial power supply e…

$902.99
Special Order
Usually Ships in 2-3 Weeks

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Experts for pre and post-sales support
Technical and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

Specialized training • U.S - based

Senior Specialist • 877-277-7147

Lifesafety Power FPO75-B100C8D8E4M1 75W power supply 6A/12V or 3

$902.99

Overview

SKU: FPO75-B100C8D8E4M1
Condition: New
Availability: Special Order · Usually Ships in 2-3 Weeks
Warranty Manufacturer Warranty

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Lifesafety Power FPO75-B100C8D8E4M1 75W Power Supply with Multi-Output Control Module

Overview

The FPO75-B100C8D8E4M1 is a 75W industrial power supply engineered for access control and security integration environments where dual-voltage output, relay switching, and supervised auxiliary circuits are mandatory. This module delivers 6A at 12VDC or 3A at 24VDC primary output, with adjustable 5–18V secondary @ 4A max — enabling heterogeneous powered endpoint architectures on a single supply rail. The 8 Class 2 power-limited relay lock control outputs (fused independently at 3A per output) support per-output failsafe/failsecure/FAI (Fail as Is) selection, critical for networked door and gate controllers. Eight additional DC auxiliary outputs (also 3A fused, selectable per Bus1/Bus2) provide supervised monitoring and distribution to subordinate access devices, reducing point-of-failure risk in larger integration schemes.

Compatibility & Integration

The module fits E4 enclosure geometry (24H × 20W × 4.5D inches) with Mercury back plate and door-mount kit included, integrating into standard electrical cabinet and wall-mount scenarios. Output voltage selection and per-output control mode configuration support mixed-voltage installations where power infrastructure must serve both legacy 12VDC and modern 24VDC access readers, magnetic locks, and request-to-exit devices. Relay and auxiliary output selectability (failsafe vs. failsecure per output) accommodates varying security postures across multiple access points on a single supply — typical in warehouse automation, facility perimeter control, and multi-zone entry environments.

Installation Considerations

Each relay and auxiliary output carries independent 3A fusing, limiting fault propagation if a downstream load shorts or draws excess current. Secondary adjustable output (5–18V @ 4A) supports auxiliary sensors, status indicators, and low-power control circuits without requiring a separate power tap. Configurable output destination (Bus1/Bus2) enables logical segmentation of loads, reducing interdependency when integrated with networked access control panels or supervisory switching systems.

Specifications
Form Factor: E4 enclosure module with door-mount hardware
Operating Temperature: Not specified in evidence
Approvals: Class 2 power-limited per specification
Input Voltage: Not specified in evidence
Output Voltage: 12VDC @ 6A or 24VDC @ 3A primary; 5–18VDC @ 4A max secondary
Max Current: 6A @ 12VDC or 3A @ 24VDC (primary); 4A secondary
Number of Outputs: 8 relay lock control + 8 DC auxiliary = 16 total supervised outputs
Battery_Backup: Not specified in evidence
Board_Dimensions: Not specified in evidence
Enclosure_Dimensions: 24H × 20W × 4.5D inches
PoE_Budget: Not applicable
Supervision: Per-output configurable; relay outputs selectable for failsafe, failsecure, or FAI; auxiliary outputs selectable for Bus1 or Bus2 assignment
Q&A
Reviews
Have Questions? Ask an Expert.

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources