APC by Schneider Electric PDM3460IEC309-200 Power Distribution Module
200A power distribution module designed to provide reliable power to high-density IT equipment racks
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The PDM3460IEC309-800 is a 3-phase IT power distribution module from APC by Schneider Electric designed to deliver 208V, 60A three-phase power directly to high-density rack equipment — the kind of load you encounter in data centers, edge deployments, and dense surveillance server rooms where single-phase circuits simply can't keep up. It accepts a 3-phase input at 200–240V permissible range and outputs via a single IEC 309 60A 3P+PE connector, giving you a clean, standards-compliant power handoff at 60 Hz. If you've been sourcing power distribution for high-draw network video recorders, storage arrays, or compute clusters, this unit belongs early in your rack design conversation.
The PDM3460IEC309-800 (often searched as PDM3460IEC309 800) is built to sit between your facility's 3-phase power feed and the rack-level power distribution equipment — typically an APC rack PDU or directly to equipment with IEC 309 inlets. When planning an installation alongside network switches and high-channel-count NVR stacks, map your aggregate load against the 60A maximum before finalizing the circuit design; derate to 80% (48A) for continuous loads per standard electrical practice. The 3-phase configuration also provides inherent load balancing across the three legs, which reduces neutral current and can simplify your facility panel loading versus stacking multiple single-phase circuits to the same aggregate capacity. Pair with appropriately rated APC rack PDUs that accept IEC 309 input for downstream single-phase distribution to individual rack units — see the power distribution category for compatible downstream options.
Q: What is the maximum current the PDM3460IEC309-800 can handle?
A: The PDM3460IEC309-800 is rated for a maximum line current of 60A and a maximum current draw of 60A at 208V 3-phase. For continuous loads, derate to 80% (48A) per standard electrical code practice.
Q: What output connector does the PDM3460IEC309-800 use?
A: It uses a single IEC 309 60A 3-phase plus protective earth (3P+PE) connector for the output. This is an industrial locking connector rated for the full 60A output of the unit.
Q: Is the PDM3460IEC309-800 compatible with 50 Hz installations?
A: No. This unit is rated for 60 Hz network frequency, which covers North American grid installations. For 50 Hz facilities, a different APC model is required.
Q: What is the warranty on the PDM3460IEC309-800?
A: APC provides a 1-year repair or replace manufacturer warranty on the PDM3460IEC309-800.
Q: What input voltage range does the PDM3460IEC309-800 accept?
A: The permissible input voltage range is 200–240V at 3 phases, 60 Hz. The nominal operating voltage is 208V 3-phase.
Q: Can the PDM3460IEC309-800 be rack-mounted?
A: Yes. The unit measures 44.5 cm wide × 40.6 cm deep × 12.7 cm tall and weighs 5.55 kg, sized for integration into standard 19-inch rack enclosures. Confirm U-height clearance in your rack plan before installation.

When I look at the PDM3460IEC309-800, the spec that drives the entire conversation is the 60A max line current at 208V 3-phase — that's the ceiling, and it's a real one. In high-density surveillance deployments where you're running a 64-channel NVR stack, dual redundant switches, and a full drive shelf, your aggregate load can push well past what any single-phase 20A or 30A circuit can legally carry at 80% continuous derate. This module is the right upstream component when your rack design arithmetic tells you that single-phase distribution simply won't get there.
Technical Highlights:
Deployment Considerations:
The PDM3460IEC309-800 fits squarely into enterprise data center racks and high-density surveillance machine rooms where the facility already provides 3-phase 208V power and the rack design calls for a clean, standards-compliant 60A distribution handoff to downstream PDUs — it's the correct upstream component for that specific architecture, and the wrong one for anything lighter.