APC by Schneider Electric PDM3460IEC309-200 Power Distribution Module
200A power distribution module designed to provide reliable power to high-density IT equipment racks
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The PDM3460IEC309-620 is APC by Schneider Electric's 3-pole, 4-wire IT Power Distribution Module rated for 60A at 208V, delivering high-density power consolidation for data center rows and large equipment cabinets where you need both metering and environmental monitoring in a single 1U-style package. With a single IEC 309 output connector, a 6.2-meter cable, and a built-in LCD display backed by Web/SNMP management, this PDM is purpose-built for enterprise environments where granular power visibility isn't optional.
Unlike simpler strip PDUs, the PDM3460IEC309-620 sits at the top of the distribution chain — it takes a 60A 3-phase feed and presents it as a managed, monitored output to downstream distribution or directly to high-draw equipment. That distinction matters when you're designing a power architecture for high-density compute or large UPS output circuits.
The Web/SNMP management interface on the PDM3460IEC309-620 (often searched as PDM3460IEC309 620) is compatible with any NMS platform that supports standard SNMP polling or trap reception. For APC EcoStruxure customers, the unit slots naturally into existing power monitoring dashboards. For non-APC environments, the SNMP interface makes this unit agnostic — configure your OID mappings once and monitor it alongside the rest of your network-managed infrastructure.
The IEC 309 output connector is the industrially common 3P+N+E 60A format. Confirm your downstream device or distribution panel uses the matching receptacle before ordering — IEC 309 variants differ by ampacity and pin configuration, and a mismatch here requires an adapter or field-termination that should be planned ahead of deployment.
Input power comes from a 208V, 60Hz circuit, making this unit specific to North American 3-phase power infrastructure. It is not dual-voltage and will not operate on 240V single-phase or international 50Hz feeds without verified compatibility review.
Q: What type of output connector does the PDM3460IEC309-620 use, and can I connect multiple devices directly?
A: The PDM3460IEC309-620 has a single IEC 309 output connector. It is designed to feed a downstream distribution panel or rack PDU rather than individual devices. If you need per-outlet monitoring at the device level, pair it with a per-outlet monitored PDU downstream.
Q: Does the PDM3460IEC309-620 support SNMP monitoring, and will it integrate with third-party NMS platforms?
A: Yes. The management platform is Web/SNMP, which means it will integrate with any NMS that supports standard SNMP polling — including SolarWinds, PRTG, Nagios, and similar platforms. No proprietary agents are required.
Q: What input voltage and frequency does the PDM3460IEC309-620 require?
A: The unit requires a 208V nominal input at 60 Hz. It is designed for North American 3-phase power infrastructure and is not rated for 50 Hz international feeds or single-phase 240V circuits.
Q: Is the PDM3460IEC309-620 UL listed?
A: Yes, it carries UL certification and RoHS compliance certification. UL listing satisfies most U.S. data center facility and insurance requirements.
Q: How long is the cable on the PDM3460IEC309-620?
A: The cable length is 6.2 meters (approximately 20 feet), which provides enough reach for most raised-floor or overhead cable routing scenarios from a floor-level UPS or panelboard to a row of racks.
Q: What is the maximum current draw supported by the PDM3460IEC309-620?
A: Maximum input current per phase and maximum total current draw per phase are both rated at 60A. Size your upstream breaker and feeder cable to this rating; do not exceed 60A on the input circuit.

The PDM3460IEC309-620 is a 60A/208V metered and monitored power distribution module — not a strip PDU. That single-output IEC 309 topology tells you exactly where this unit belongs: at the top of a two-tier distribution architecture, sitting between a large UPS or panel breaker and a set of downstream rack PDUs. If you're trying to wire individual servers directly into it, you've picked the wrong product.
Technical Highlights:
Deployment Considerations:
This unit is the right pick for enterprise data centers running 208V 3-phase infrastructure where you need metered, SNMP-visible power at the row distribution level — specifically scenarios like colocation cage feed monitoring or modular data hall buildouts where per-row visibility drives capacity decisions.