APC by Schneider Electric IT POWER DISTRIBUTION MODULE 3 - PDM3460IEC309-200
200A power distribution module designed to provide reliable power to high-density IT equipment racks
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APC by Schneider Electric PDM3516IEC-1040 is a 3-pole, 5-wire, 16A IEC309 IT Power Distribution Module built for data center environments where space efficiency, safe distribution, and active power monitoring are non-negotiable. If you're provisioning rack power for dense compute or networking deployments, this unit addresses the two most common failure points: unmonitored consumption creep and under-rated connectors. With a UL-listed design and both local and web-based monitoring, it gives operations teams the visibility they need before a circuit gets overloaded — not after. The PDM3516IEC-1040 (often searched as PDM3516IEC 1040) fits squarely into structured power distribution unit deployments where input-grade IEC309 connections and per-unit capacity management matter.
The PDM3516IEC-1040 integrates into standard APC by Schneider Electric power infrastructure architectures and is designed to work alongside APC's broader data center management ecosystem. The IEC309 input is compatible with standard colocation and enterprise data center power whip assemblies, eliminating the need for custom adapters in most facilities. For environments already running APC's EcoStruxure or similar DCIM platforms, the web-based monitoring interface supports centralized power reporting. If you're building out a structured cabling and power layer for a new data hall or expanding an existing one, pair this with appropriate rack enclosures and UPS systems to complete the power protection chain. For environments where per-outlet switching or outlet-level metering is required, consider stepping up to APC's Switched or Metered PDU families — the PDM3516IEC-1040 provides aggregate monitoring, not granular per-outlet control.
Q: What input connector does the PDM3516IEC-1040 use?
A: The PDM3516IEC-1040 uses an IEC309 input connector rated at 16A, 3-pole, 5-wire. This is the standard industrial-grade connector used in colocation and enterprise data center power distribution.
Q: Does the PDM3516IEC-1040 support remote power monitoring?
A: Yes. The PDM3516IEC-1040 supports both local and web-based monitoring, allowing operations teams to track power consumption remotely without physical access to the rack.
Q: Is the PDM3516IEC-1040 UL listed?
A: Yes. The PDM3516IEC-1040 meets UL requirements, making it suitable for deployments in facilities subject to NEC (NFPA 70) jurisdiction and insurance underwriting that requires independently certified electrical equipment.
Q: Does the PDM3516IEC-1040 provide per-outlet switching or metering?
A: No. The PDM3516IEC-1040 provides aggregate-level monitoring rather than per-outlet switching or individual outlet metering. If per-outlet control is required, consider APC's Switched or Metered PDU product families.
Q: What is the phase configuration of the PDM3516IEC-1040?
A: The PDM3516IEC-1040 is a 3-pole, 5-wire unit, supporting balanced three-phase power distribution — the correct configuration for reducing neutral overcurrent risk in multi-server rack environments.

The PDM3516IEC-1040 is one of those units that doesn't get a lot of fanfare but does a specific job reliably — 16A IEC309 input with 3-pole/5-wire wiring, aggregate monitoring, and a UL listing. Where I see it deployed most often is in colocation cages and enterprise data halls where the facility provides IEC309 whip feeds from overhead busway or floor PDUs, and the tenant needs a cost-controlled way to distribute and monitor that feed at the rack level without paying for per-outlet switching they'll never use.
Technical Highlights:
Deployment Considerations:
Best fit: colocation tenants or enterprise IT teams provisioning rack power in IEC309-fed data halls where the priority is UL-compliant, monitored distribution at a controlled cost — not outlet-level management.