Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The APC by Schneider Electric ACRD100 is a 300mm-wide InRow row-based precision cooling unit engineered for high-density data center aisles where traditional room cooling falls short. Operating at 208–230V / 60Hz and drawing 4,600W under load, this tower-form unit delivers up to 9,900W of cooling capacity — putting meaningful thermal headroom within reach for dense compute rows without requiring a full-scale raised-floor CRAC overhaul. If you're managing per-rack heat loads in the 5–10kW range and your room-level cooling is already struggling, the ACRD100 is worth a close look as part of a data center cooling infrastructure refresh.
Row-based cooling positions the thermal exchange point directly adjacent to the heat source rather than at the room perimeter, which is the fundamental reason InRow architecture outperforms perimeter units at density. The ACRD100 mounts in its own 42U-compatible footprint alongside your equipment racks, capturing hot exhaust air at the source and recirculating conditioned air into the cold aisle — a geometry that standard room units simply cannot replicate at scale.
The ACRD100 is designed to integrate into precision cooling deployments alongside APC's InRow product family and is compatible with APC's EcoStruxure IT and Data Center Expert (DCE) management platforms for environmental monitoring and thermal management. The unit operates at 230V AC / 60Hz — confirm your facility's available voltage and branch circuit ampacity before ordering, as 208V and 230V behave differently at the distribution panel. Row-based deployments typically pair this unit with APC by Schneider Electric NetShelter rack enclosures and hot-aisle containment kits to achieve the containment geometry that makes InRow cooling effective. Without containment, airflow bypasses the heat exchange path and efficiency drops substantially. If you're evaluating rack PDU options alongside this unit, plan branch circuits for both the cooling load (4,600W) and IT load simultaneously — a common oversight in phased deployments.
Q: What is the cooling capacity of the ACRD100?
A: The ACRD100 provides up to 9,900W (approximately 9.9kW) of cooling capacity. This is suited for high-density rack rows with per-rack heat loads in the 5–10kW range.
Q: What input voltage does the ACRD100 require?
A: The ACRD100 requires 208–230V AC / 60Hz input. Verify your facility's available branch circuit voltage and ampacity before ordering — this unit is not compatible with standard 120V circuits.
Q: How much floor space does the ACRD100 occupy?
A: The unit measures 11.8 inches wide x 42.1 inches deep x 78.4 inches tall and weighs approximately 404 lb. Floor load capacity must be verified as part of site preparation before installation.
Q: Does the ACRD100 require a chilled water connection?
A: No. The ACRD100 is an air-cooled unit, so it does not require a chilled water loop or hydronic infrastructure. Heat rejection relies on the building's ambient HVAC system rather than a dedicated chiller circuit.
Q: What is the warranty on the ACRD100?
A: APC includes a 1-year limited warranty with the ACRD100. Extended service options may be available — evaluate against your facility's uptime requirements.
Q: Does the ACRD100 need hot-aisle containment to operate effectively?
A: Hot-aisle containment is not strictly required for the unit to operate, but InRow cooling efficiency depends heavily on containing airflow paths. Without proper containment, conditioned air bypasses IT equipment and recirculates ineffectively — plan containment as part of the deployment, not as an afterthought.

When I look at the ACRD100, the spec I immediately focus on is the 9,900W cooling capacity against a 4,600W power draw — that's a cooling efficiency ratio worth calculating before any alternatives. In a row-based deployment where you're managing 8–10kW racks, this unit can absorb the heat load of a fully populated high-density row while staying within a predictable power budget at the branch circuit level.
Technical Highlights:
Deployment Considerations:
The ACRD100 fits cleanest in a mid-scale enterprise data center or colocation cage running 8–12 high-density compute racks where chilled-water infrastructure isn't available but perimeter cooling has already proven inadequate. It is not the right tool for a single low-density rack or for a facility that already has a robust chilled-water distribution system — in both cases, alternative APC InRow configurations will serve better.