APC by Schneider Electric Inrow RD 600MM - ACRD600P
N in-row air-cooled unit designed to provide targeted cooling for IT racks in data centers and server rooms
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The ACRD601 is APC by Schneider Electric's InRow RD 600mm air-cooled precision cooling unit designed for high-density data center rows. Running on 460/480V at 60Hz, this unit deploys directly alongside server racks to deliver targeted cooling exactly where heat is generated — rather than relying on perimeter cooling that leaves hot spots between aisles. At 42U tall and 23.6 inches wide (600mm), it fits a standard rack footprint, letting you integrate cooling capacity into the row without dedicating separate floor space to remote CRAC units. For enterprise data centers, colocation facilities, or large network operations centers scaling beyond what perimeter cooling can handle, the ACRD601 represents a purpose-built data center cooling solution sized for production deployments.
The ACRD601 is designed for integration into APC InRow cooling architectures and is intended to be managed alongside APC's broader power distribution and monitoring ecosystem. InRow RD units in the ACRD6xx family are typically managed via APC's EcoStruxure IT or NetBotz environmental monitoring platforms, enabling centralized temperature, airflow, and energy monitoring across the data center row. Pairing with APC network management cards allows SNMP/web-based remote monitoring — confirm exact management card compatibility with APC for this voltage variant before procurement. The 460/480V electrical requirement means this unit is not interchangeable with the 208V variants in the InRow RD family; ensure your mechanical and electrical contractors are spec'd to the correct model from the outset.
Q: What voltage is required to operate the ACRD601?
A: The ACRD601 requires 460/480V at 60Hz — this is a three-phase North American voltage unit. It is not compatible with 208V single-phase or standard 120V circuits. Confirm your facility's electrical distribution before specifying this model.
Q: What refrigerant does the ACRD601 use?
A: The ACRD601 uses R410A refrigerant, the current standard for precision cooling equipment of this class. It is widely serviceable but subject to EPA phase-down timelines; factor this into long-term facility planning for deployments expected to run beyond 2030.
Q: What is the physical footprint of the ACRD601?
A: The unit is 600mm (23.6 inches) wide, 78.4 inches tall (42U), and 42.1 inches deep. It weighs 862 pounds installed, which requires floor loading verification before placement.
Q: Is the ACRD601 compatible with hot-aisle/cold-aisle containment systems?
A: Yes — the 42U full rack height and 600mm width are specifically sized to integrate with standard row-based containment architectures. The unit's dimensions must align with adjacent racks to ensure containment integrity; gaps in height or width will compromise aisle separation.
Q: Can the ACRD601 be managed remotely?
A: InRow RD units are designed for integration with APC's EcoStruxure IT and NetBotz environmental monitoring platforms. Remote management capability typically requires compatible APC network management cards — confirm specific card compatibility with APC for this voltage variant before ordering.

The ACRD601 is a unit I'd spec specifically when you're dealing with three-phase 460/480V electrical infrastructure and need InRow cooling to fit a 600mm rack row. At 862 pounds and 42.1 inches deep, this isn't a unit you drop into a small server room — it's engineered for purpose-built data center environments where row-based cooling architecture is already part of the design. The ACRD601's 42U height is the detail that makes or breaks containment: if you're building a hot-aisle containment enclosure, every rack and cooling unit in that row needs to be the same height or you're engineering air bypass back into the system.
Technical Highlights:
Deployment Considerations:
The ACRD601 is the right specification for enterprise data centers and colocation facilities running three-phase 460/480V distribution where row-based precision cooling needs to integrate directly into a 600mm rack row without physical compromise to aisle containment architecture.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more APC by Schneider Electric products? Shop the full APC by Schneider Electric catalog →