APC by Schneider Electric Hyperpod Door - Single Hinged Door - FS-DR-1002-U

APC by Schneider Electric FS-DR-1002-U Hyperpod Single Hinged DoorOverviewThe APC by Schneider Electric FS-DR-1002-U is a single hinged door designed …

$1,675.00 $1,136.99 SAVE $538
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric Hyperpod Door - Single Hinged Door - FS-DR-1002-U

$1,675.00
$1,136.99

Overview

SKU: FS-DR-1002-U
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric FS-DR-1002-U Hyperpod Single Hinged Door

Overview

The APC by Schneider Electric FS-DR-1002-U is a single hinged door designed for the Hyperpod modular enclosure system. Standing 2005mm tall and 150mm wide, it is sized to match full-height Hyperpod bays and provides physical access control to enclosed equipment while keeping the installation profile consistent with the surrounding structure. If you are specifying or expanding a Hyperpod deployment in a server room, communications closet, or structured wiring environment, the FS-DR-1002-U (often searched as FS DR 1002 U) is the door component that completes the enclosure configuration.

This is a purpose-built enclosure accessory, not a standalone rack or cabinet. It ships as a single unit — one door — and integrates directly with compatible Hyperpod frame assemblies. The black finish matches standard Hyperpod system color coordination.

Key Features

  • Full-height 2005mm door panel: At 2005mm tall, this door spans the full height of a standard Hyperpod bay, ensuring no gaps in the physical enclosure envelope. Partial-height doors on full-height frames create airflow bypass and access vulnerabilities — this unit eliminates both issues when installed correctly.
  • 150mm width profile: The 150mm door width is matched to the Hyperpod system's structural width. Attempting to fit a mismatched door dimension to a Hyperpod frame wastes time on-site; specifying FS-DR-1002-U against confirmed Hyperpod inventory removes that variable.
  • 935mm depth clearance: The 935mm depth figure governs clearance requirements for the enclosure run. Verify your aisle or wall-offset plan accommodates this before finalizing the room layout — a common oversight on dense deployments is insufficient depth clearance for door swing.
  • Black finish: Matches the standard Hyperpod color family, keeping visual consistency across mixed-bay deployments. Mismatched colors in structured environments draw attention and can flag non-standard substitutions during audits.
  • UL, cUL, and CE certified: Carries UL, cUL (Canadian), and CE certifications. UL and cUL listings satisfy most North American AHJ (Authority Having Jurisdiction) requirements for enclosure hardware in commercial and data center installations. CE covers European conformity. Specify these certifications in your submittal package to avoid change orders.
  • Single hinged door configuration: The single-door format is appropriate for Hyperpod bays where a full swing is acceptable and a double-door split is not needed. For narrow aisles or constrained access points, confirm swing clearance before ordering — a double-door variant may serve better in tight quarters.
  • 5-year manufacturer warranty: A 5-year warranty on a passive enclosure component reflects the product's expected service life in commercial infrastructure. Enclosure hardware is typically a set-and-forget element; a 5-year coverage window aligns with standard data center refresh cycles.

Integration & Compatibility

The FS-DR-1002-U is designed specifically for the APC by Schneider Electric Hyperpod modular enclosure system. Before ordering, confirm your Hyperpod frame model and bay configuration to verify door compatibility — Hyperpod systems span multiple frame widths and heights, and door fitment is frame-specific. This door does not carry independent rack or PDU mounting capability; it is a door panel only.

For broader server rack enclosure planning, including full Hyperpod system builds, confirm all frame, side panel, and door components against the Hyperpod configuration guide for your specific bay count and layout. Mixing door types (hinged vs. split) within a single Hyperpod run is possible but requires deliberate planning at the design stage.

If your project also involves power distribution or cable management within the enclosure, address those requirements at the frame selection stage — door choice does not affect internal PDU or cable management compatibility, but frame depth does.

What's in the Box

  • 1x FS-DR-1002-U Single Hinged Door

Frequently Asked Questions

Q: What enclosure system is the FS-DR-1002-U designed for?

A: The FS-DR-1002-U is a door component built specifically for the APC by Schneider Electric Hyperpod modular enclosure system. It is not a universal door and should only be ordered after confirming compatibility with your specific Hyperpod frame model and bay configuration.

Q: What are the certified dimensions of the FS-DR-1002-U door?

A: The door measures 150mm wide, 2005mm tall, and 935mm in depth. These dimensions correspond to full-height Hyperpod bay sizing. Confirm your frame dimensions match before ordering.

Q: What certifications does the FS-DR-1002-U carry?

A: The FS-DR-1002-U is UL, cUL, and CE certified. UL and cUL listings address North American commercial and data center installation requirements; CE covers European conformity.

Q: What is the warranty on the FS-DR-1002-U?

A: APC by Schneider Electric provides a 5-year manufacturer warranty on the FS-DR-1002-U.

Q: Does the FS-DR-1002-U ship as a single unit or as a pair?

A: The FS-DR-1002-U ships as a single door — quantity per pack is 1. If your Hyperpod bay requires two doors (e.g., a split double-door configuration), order accordingly or verify whether a dedicated double-door part number better suits your layout.

Q: What is the packaged weight of the FS-DR-1002-U?

A: The packaged weight is 20 kg (approximately 44 lbs). Plan for two-person handling during installation given the door's 2005mm height and packaged dimensions.

Eden Phillips
Eden Phillips

The FS-DR-1002-U is a single hinged door for the APC Hyperpod modular enclosure system — at 2005mm tall and 150mm wide, it is dimensioned to fill the full face of a standard Hyperpod bay. The detail I flag most often when this comes up in a project spec is the 935mm depth: that number governs your door-swing clearance requirement, and it is frequently overlooked until the enclosure run is already positioned in the room.

Technical Highlights:

  • Full-height 2005mm panel: Covers the entire bay face without trim gaps — relevant wherever you need consistent physical access boundaries across a multi-bay Hyperpod row.
  • UL, cUL, CE certification triple: Covers North American AHJ submittals (UL + cUL) and European conformity (CE) in one part number — no need to source a region-specific variant for mixed-jurisdiction projects.
  • 5-year manufacturer warranty: Passive enclosure hardware is infrastructure-grade, long-life equipment; the 5-year coverage window reflects that and aligns with standard data center hardware refresh intervals.

Deployment Considerations:

  • Packaged weight is 20 kg at 2005mm tall — two-person installation is practical. Narrow aisles with staging constraints can make this awkward; plan the delivery path before scheduling the install crew.
  • This is a door panel only — it does not carry any integrated locking hardware, handle hardware, or cable pass-through features beyond what the Hyperpod frame system provides. If your deployment requires keyed access or electronic locking, those components must be specified separately against Hyperpod-compatible hardware.

The FS-DR-1002-U fits cleanly into a structured Hyperpod build for a commercial server room or communications room where you need certified, full-height enclosure closure on a modular bay — and where documentation for UL/cUL/CE compliance is part of the construction submittal package.

Specifications
Type: Door
Product colour: Black
Certification: cUL, CE, UL
Width: 150 mm
Depth: 935 mm
Height: 2005 mm
Weight: 20 kg
Quantity per pack: 1 pc(s)
Package width: 1100 mm
Package depth: 214 mm
Package height: 2005 mm
Package weight: 20 kg
Warranty period: 5 year(s)
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources