Vertiv GXT5 3000VA UPS W/RDU101 - GXT5-3000LVRT2UXLN

Vertiv GXT5-3000LVRT2UXLN 3000VA Online Double-Conversion Rack/Tower UPSOverviewThe Vertiv GXT5-3000LVRT2UXLN is a 3000VA / 2700W online double-conver…

$6,222.00 $4,055.99 SAVE $2166
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Vertiv GXT5 3000VA UPS W/RDU101 - GXT5-3000LVRT2UXLN

$6,222.00
$4,055.99

Overview

SKU: GXT5-3000LVRT2UXLN
UPC: 767041029215
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GXT5-3000LVRT2UXLN 3000VA Online Double-Conversion Rack/Tower UPS

Overview

The Vertiv GXT5-3000LVRT2UXLN is a 3000VA / 2700W online double-conversion UPS designed for rack or tower deployment in server rooms, network closets, security head-end rooms, and edge compute environments where utility power quality cannot be trusted. Unlike line-interactive or standby topologies, double-conversion means protected loads never see raw utility power — the inverter is always online, eliminating transfer time entirely. For power protection and UPS systems where even a half-cycle gap is unacceptable — NVRs mid-write, access control servers, VoIP gateways — that zero-transfer-time topology is the deciding spec. The GXT5-3000LVRT2UXLN ships in a compact 2U form factor (3.4 in H × 16.9 in W × 21.3 in D) that fits standard 19-inch racks while remaining convertible to tower orientation, giving integrators flexibility when rack space is constrained at an edge site.

Key Features

  • Online Double-Conversion Topology: The inverter carries the load continuously — no switchover delay, no voltage sag on transfer. NVRs, servers, and PoE switches stay online through utility brownouts, sags, and outages without a hiccup. This is the topology required whenever the equipment itself cannot tolerate even a momentary interruption.
  • 3000VA / 2700W Capacity: At 2700W continuous output, this unit handles a dense rack segment — a mid-size NVR with drives spinning, a managed PoE switch, and several edge servers simultaneously. Size your load to 80% of rated capacity (roughly 2160W) for thermal headroom and runtime extension during an outage.
  • Up to 98% Efficiency in Active ECO Mode: ECO mode routes utility power through a bypass path when power quality is within tolerance, reducing heat output and operating costs compared to a conventional on-line UPS running at 90–92%. At a typical data center electricity rate, the difference in efficiency on a unit running 24/7 adds up over a multi-year deployment. On-line mode holds 95% efficiency when ECO is not active.
  • Wide Input Voltage Range (60–150V): The 60–150V acceptance window means the UPS rides through deep brownouts and over-voltage events without switching to battery. In commercial buildings with aging electrical infrastructure or facilities on the same circuit as HVAC compressors, this tolerance keeps battery runtime in reserve for genuine outages rather than burning cycles on routine voltage swings.
  • User-Configurable Output Voltage (110/115/120/125VAC ±3%): Output can be set to match the specific voltage requirement of connected equipment rather than simply passing through whatever the utility delivers. Useful when protecting sensitive lab or AV gear that specifies a tighter input tolerance.
  • Seven Output Receptacles — Four Programmable: The outlet configuration (1× L5-30R + 6× 5-20R) covers both high-draw devices via the twist-lock and standard equipment on the 5-20R outlets. Four of the six 5-20R outlets are individually programmable — enabling sequenced load shedding or outlet-level cycling via software without touching the rack. The remaining 1× L5-30R and 2× 5-20R outlets are non-programmable, always-on.
  • NEMA L5-30P Input Plug: The twist-lock input connects to a dedicated 30A circuit, appropriate for a 2700W load. Verify your panel has a 30A circuit available at the rack location before ordering — this is a hard infrastructure requirement that occasionally gets missed until installation day.
  • Gravity-Sensing Color LCD Control Panel: The display auto-orients when the unit is rotated between rack and tower, so readouts stay right-side-up regardless of mounting. Real-time status, configuration menus, and alarm acknowledgment are all available at the front panel without a laptop or network connection.
  • IntelliSlot RDU101 Communications (Included per Product Name): The GXT5-3000LVRT2UXLN variant ships with the RDU101 card, enabling SNMP and web-based monitoring out of the box. This means UPS status, load percentage, battery health, and event logs are visible in your NMS or DCIM platform immediately — no additional card purchase required. USB, RS485, RS232, and terminal block interfaces are also present for environments not running SNMP.
  • ENERGY STAR 2.0 / UL 1778 / RoHS2 / REACH Certified: ENERGY STAR 2.0 certification confirms the efficiency claims are independently verified, not just marketing figures. UL 1778 4th edition listing covers the safety requirements for UPS equipment in North American commercial installations. RoHS2 and REACH compliance support environmental procurement requirements common in government and enterprise contracts.

Integration & Compatibility

The Vertiv power protection line integrates with a broad range of DCIM and NMS platforms via SNMP when the RDU101 card is installed. The serial interfaces (RS232/RS485) support legacy monitoring systems and out-of-band management paths when the network is down. The external battery connector enables runtime extension with compatible Vertiv extended battery modules — confirm model compatibility with Vertiv's battery extension list before ordering additional runtime. For PoE network switch deployments and network video recorders where uninterrupted recording is critical, pairing this UPS with a runtime-matched battery extension module is the standard architecture. A UPS sizing and runtime guide can help you match battery runtime to your actual load and outage duration requirements.

Frequently Asked Questions

Q: What is the input plug type for the GXT5-3000LVRT2UXLN, and what circuit does it require?

A: The input uses a NEMA L5-30P twist-lock plug, which requires a dedicated 30A / 120V circuit at the installation point. Confirm panel availability before deployment — this is a hard infrastructure requirement.

Q: Does the GXT5-3000LVRT2UXLN include SNMP monitoring capability, or is that an add-on?

A: This model ships with the RDU101 communications card installed, enabling SNMP and web-based management out of the box. USB, RS232, RS485, and terminal block interfaces are also available for non-SNMP environments.

Q: What is the transfer time to battery when utility power fails?

A: Zero. The GXT5-3000LVRT2UXLN uses online double-conversion topology — the inverter is always the active power source, so there is no transfer event when utility power drops. Connected loads see no interruption.

Q: Can this UPS be installed in both a rack and tower orientation?

A: Yes. The 2U form factor (3.4 in H × 16.9 in W × 21.3 in D) fits standard 19-inch equipment racks, and the unit converts to tower orientation. The gravity-sensing LCD auto-orients in either position.

Q: What certifications does the GXT5-3000LVRT2UXLN carry?

A: ENERGY STAR 2.0, UL 1778 4th edition, CSA 22.2 No. 107.1, RoHS2, REACH, and WEEE.

Q: What is the maximum efficiency of this UPS?

A: Up to 98% in Active ECO Mode, and up to 95% in standard on-line double-conversion mode.

James Everett
James Everett

The GXT5-3000LVRT2UXLN is the model I specify when a head-end rack needs true double-conversion protection and the site electrician has already pulled a 30A dedicated circuit. The 98% ECO mode efficiency is the standout operational spec here — on a unit running continuously at a mid-load of around 1500W, moving from a 92% efficient older UPS to 98% ECO mode recovers roughly 90W of heat and the proportional electricity cost, year over year. That matters in edge closets without dedicated CRAC units.

Technical Highlights:

  • Zero Transfer Time: Online double-conversion means the inverter is always in the power path — no 4ms, no 8ms gap on switchover. NVRs actively writing to RAID arrays and access control servers processing transactions won't see even a momentary sag.
  • Wide Input Range (60–150V): At sites with known brownout history or shared circuits with motor loads, this input tolerance means the unit rides through voltage events on utility power rather than burning battery cycles — protecting runtime for real outages.
  • RDU101 Included: SNMP and web management are active the moment the unit is networked, with no card purchase required. UPS load, battery state, and event history are available in your NMS immediately after commissioning.

Deployment Considerations:

  • The NEMA L5-30P input is a non-negotiable infrastructure requirement — if the rack location only has 5-20R receptacles available, a 30A circuit extension or panel work is required before installation. Confirm this at the site survey stage, not on installation day.
  • ECO mode efficiency gains come with a trade-off: in ECO mode the load is briefly on bypass when switching, which introduces a very short transfer time. For equipment with ultra-sensitive power supplies, verify tolerance before enabling ECO mode.

This unit is well-matched to a security operations head-end: a 32-channel NVR with a full drive complement, a managed PoE switch feeding 16–24 cameras, and a workstation at the console — that load profile sits comfortably inside the 2700W capacity at under 80% utilization, leaving thermal headroom and meaningful battery runtime during an outage.

Specifications
Weight: 66 lb
Height: 3.4 in
Width: 16.9 in
Depth: 21.3 in
Operating Temp: +32 to +104 °F (0 to 40 °C)
Power Rating: 3000VA / 2700W
Input Voltage Range: Typical: 120V / Range: 60-150V
Output Voltage Range: 110/115/120/125VAC; (user-configurable); ±3%
Efficiency: Up to 98% Active ECO Mode; up to 95% on-line mode
Wiring: Input: NEMA L5-30P; Output: L5-30R+5-20R × 6
Interface Options: Optional communications card (Vertiv™ Liebert® IntelliSlot™ RDU120), USB, RS485, RS232, terminal block, external battery connector
Protocols: SNMP and web management enabled with optional Vertiv™ Liebert® IntelliSlot™ RDU120 communications card; serial connection for out-of-band management
Control Panel: Colored graphic LCD with gravity sensing orientation, provides insight to UPS status for easy installation, configuration and operation
Operating Temperature: +32 to +104 °F (0 to 40 °C)
General: Output Receptacles: 1 x L5-30R + 5-20R × 6; 4 x 5-20R individually programmable receptacles and 1 x L5-30R and 2 x 5-20R non-programmable receptacles
Listings: ENERGY STAR 2.0 certified, WEEE, RoHS2, REACH, UL 1778 4th edition and CSA 22.2 No. 107.1
Topology: On-line double conversion UPS; compact and flexible rack/tower form factor
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources