Vertiv GXT5LI-3000LVRT2UXLN 3000VA Lithium-Ion Online Double-Conversion Rack UPSOverviewThe Vertiv GXT5LI-3000LVRT2UXLN is a 3000VA / 2700W online dou…

$8,444.00 $5,159.99 SAVE $3284
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Vertiv GXT5 3000VA L-ion UPS W/RDU101 - GXT5LI-3000LVRT2UXLN

$8,444.00
$5,159.99

Overview

SKU: GXT5LI-3000LVRT2UXLN
UPC: 767041038002
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GXT5LI-3000LVRT2UXLN 3000VA Lithium-Ion Online Double-Conversion Rack UPS

Overview

The Vertiv GXT5LI-3000LVRT2UXLN is a 3000VA / 2700W online double-conversion UPS built around a lithium-ion battery chemistry — the architecture choice that matters most for server rooms, network closets, and surveillance infrastructure where runtime predictability and weight-per-watt are real constraints. At 2U and 21.5 inches deep, it fits standard 4-post racks without a dedicated shelf, and the included Liebert IntelliSlot RDU120 network card means SNMP visibility is live from day one rather than an add-on purchase. For integrators speccing power protection for multi-camera or edge-compute deployments, the GXT5LI-3000LVRT2UXLN covers the full range of output receptacles most mixed-load racks actually need.

Key Features

  • 3000VA / 2700W Online Double-Conversion Architecture: True online topology means zero transfer time during a utility event — the load never sees a switch. For NVR arrays or PoE switch stacks where even a 4ms gap can trigger reboots, this is the correct UPS class. Budget-tier line-interactive units have 8–20ms transfer windows; this one has none.
  • Lithium-Ion Battery Chemistry: Li-ion batteries deliver a longer service life and significantly lower weight compared to VRLA equivalents at the same capacity. For a rack that gets moved during infrastructure refreshes, or a closet with limited floor loading, the weight difference is operationally meaningful. Li-ion also recharges faster after a discharge event.
  • Up to 98% Efficiency in Active ECO Mode: In online mode efficiency reaches 92%, which is solid for double-conversion. Flip to Active ECO Mode and that rises to 98% — reducing heat output and operating cost over a multi-year deployment. ECO mode still provides online-class protection, making it viable for production loads rather than just test environments.
  • User-Configurable Output Voltage (100/110/115/120/125VAC): The output voltage is software-selectable, which matters when you're integrating international equipment or legacy gear with narrow input tolerances. You don't need a separate transformer or a second UPS model for edge cases — configure it at the control panel.
  • Input Range 60–150 VAC (Full-Load Nominal: 102–150 VAC): A wide input window means the rectifier stays online through browndowns and utility sag events without switching to battery. Facilities with aging electrical infrastructure or shared branch circuits will draw down the input regularly; a 60V minimum floor keeps the UPS on utility power through most of those events, preserving battery for genuine outages.
  • Output Receptacles: (6) 5-15/20R + (1) L5-30R: Six NEMA 5-15/20R outlets cover standard C13/C14 PDUs, 1U switches, and rack-mount appliances. The L5-30R twist-lock output is available for a single high-current device or a downstream PDU — useful when one outlet needs positive retention in a vibration-prone environment.
  • Included Vertiv Liebert IntelliSlot RDU120 Network Card: SNMP/web management is bundled, not optional. You get remote monitoring, load readings, and battery status without a separate card purchase. The IntelliSlot architecture also supports card swaps if you need a different management protocol later — the slot stays accessible.
  • Color Graphic LCD with Gravity-Sensing Orientation: The display auto-rotates based on rack mounting orientation — whether the unit is installed horizontally or in a vertical configuration, the readout stays right-side up. Small detail, but relevant in mixed-orientation cabinets.
  • Interface Options: USB, RS232, Dry-Contact, IntelliSlot: Multiple parallel management paths reduce single-point-of-failure risk in the monitoring stack. Dry-contact terminals allow integration with building management systems or external monitoring panels that don't speak SNMP.
  • Listings: UL 1778, UL 1973, UL 1642, Energy Star 2.0, RoHS, WEEE, REACH: UL 1778 is the UPS safety standard; UL 1973 covers battery systems; UL 1642 addresses the Li-ion cells themselves. Energy Star 2.0 qualification confirms the efficiency ratings are independently verified, not self-reported. RoHS/REACH compliance matters for enterprise procurement teams with environmental documentation requirements.

Integration & Compatibility

The GXT5LI-3000LVRT2UXLN integrates with managed PoE switches and NVR infrastructure via its included RDU120 network card, which supports SNMP and web-based monitoring out of the box. The RS232 and USB ports support out-of-band management connections to connected servers or appliances for graceful shutdown coordination. Dry-contact terminal blocks enable integration with third-party building management or alarm systems. The IntelliSlot expansion bay accepts optional management cards if your environment requires a different protocol or redundant management paths. Operating temperature range is 32°F to 104°F (0°C to 40°C), with a 10% derating at 50°C — plan airflow accordingly in high-ambient enclosures. Pair this unit with a compatible external battery cabinet if extended runtime is required beyond the internal Li-ion pack. For full NVR and video surveillance rack designs, the 2700W real-power output typically covers a 16–32 channel NVR, a managed PoE switch stack, and associated edge compute without load-shedding concerns — verify your actual load watts, not VA, when sizing.

For buyers evaluating the broader Vertiv power protection line, the GXT5 family spans multiple capacities; the GXT5LI-3000LVRT2UXLN sits at the 3000VA tier with the Li-ion variant designation (LI in the model string). Tower-only environments or sites needing extended external battery runtime should evaluate adjacent models in the GXT5 family rather than forcing this 2U rack form factor.

Frequently Asked Questions

Q: What is the real power output (watts) of the GXT5LI-3000LVRT2UXLN?

A: The GXT5LI-3000LVRT2UXLN delivers 2700W of real power at its 3000VA rating — a 0.9 power factor. Size your load budget to watts, not VA, when calculating whether this unit fits your rack.

Q: Does the GXT5LI-3000LVRT2UXLN include a network management card?

A: Yes. The Vertiv Liebert IntelliSlot RDU120 network card is included. It provides SNMP and web-based management without an additional purchase. The IntelliSlot bay also supports card replacement or upgrade if your monitoring environment changes.

Q: What input plug does the GXT5LI-3000LVRT2UXLN require?

A: The input uses an L5-30P twist-lock plug (30A, 120V). Confirm your branch circuit and PDU can support a 30A L5-30 connection before ordering. If your facility is wired for a different input configuration, verify compatibility with your electrician.

Q: What certifications does the GXT5LI-3000LVRT2UXLN carry?

A: The unit is listed to UL 1778 (UPS safety), UL 1973 (battery systems), and UL 1642 (lithium-ion cells). It also carries Energy Star 2.0, RoHS, WEEE, and REACH compliance — relevant for enterprise environmental documentation requirements.

Q: What is the operating temperature range for the GXT5LI-3000LVRT2UXLN?

A: Operating range is 32°F to 104°F (0°C to 40°C), with a 10% output derating at 50°C. Plan rack airflow to keep ambient below 40°C at the unit's intake — Li-ion chemistry is more temperature-sensitive than VRLA under sustained high-ambient conditions.

Q: Can the output voltage on the GXT5LI-3000LVRT2UXLN be adjusted?

A: Yes. Output voltage is user-configurable to 100, 110, 115, 120, or 125VAC via the control panel. This allows the unit to serve loads with narrow input tolerances or international equipment without a separate step-up/step-down transformer.

Ted Perry
Ted Perry

When I'm speccing power protection for a surveillance or edge-compute rack, the first question is always topology — and the GXT5LI-3000LVRT2UXLN answers that with online double-conversion, which means zero transfer time. That's not a marketing distinction; it's the difference between an NVR that stays online through a utility event and one that reboots and loses a recording window. The 2700W real-power rating at 3000VA (0.9 PF) gives you honest headroom math, which I appreciate on a spec sheet.

Technical Highlights:

  • 98% Active ECO Mode Efficiency: Running at 98% versus a typical 92% in online mode means less heat per watt delivered — over a three-year deployment in a tight IDF closet, that thermal reduction is genuinely useful, not just a number on a chart.
  • Li-Ion UL 1973 + UL 1642 Listings: Both certifications cover the battery system and cells independently. In enterprise procurement, having both on a single unit simplifies the compliance documentation burden — you're not hunting for cell-level certs separately.
  • Included RDU120 Network Card: SNMP/web monitoring ships in the box. In my experience, UPS units that require a separate card purchase often get deployed without one and then become visibility blind spots. The IntelliSlot inclusion removes that variable from the project budget and the installation checklist.

Deployment Considerations:

  • The L5-30P input requires a dedicated 30A branch circuit. If your rack room is wired for standard 20A circuits, you'll need an electrician visit before this unit goes live — plan that into the project schedule, not as a day-of discovery.
  • The 10% derating above 40°C is a real constraint for equipment closets in warm climates or buildings with poor HVAC. Measure ambient at the rack intake, not at the room thermostat, before commissioning.

The GXT5LI-3000LVRT2UXLN is well-positioned for 16–32 channel NVR deployments paired with a managed PoE switch stack — the output receptacle mix (six 5-15/20R plus one L5-30R) matches what those racks actually use, and the bundled network card keeps the monitoring stack complete without line-item surprises.

Specifications
Weight: 48.5 lbs
Height: 3.4 in
Width: 16.9 in
Depth: 21.5 in
Operating Temp: 32°F to 104°F (0°C to 40°C) (10% Derating at 50°C)
Power Rating: 3000VA / 2700W
Input Voltage Range: Nominal (Full Load): 102-150 VAC; Max: 60-150 VAC
Output Voltage Range: 120V; 100/110/115/120V/125VAC (User-Configurable)
Efficiency: Up to 92% in online mode; 98% in Active ECO Mode
Wiring: Input: L5-30P; Output: (6) 5-15/20R & (1) L5-30R
Interface Options: USB, RS232, Dry-Contact Terminal Block, Intellislot (for Management Cards)
Protocols: USB, Serial for Out-of-Band Management, SNMP/Web Management with included Vertiv™ Liebert® IntelliSlot™ RDU120 Network Card
Control Panel: Color graphic LCD with gravity sensing orientation
Operating Temperature: 32°F to 104°F (0°C to 40°C) (10% Derating at 50°C)
Listings: UL 1778, UL 1973, UL 1642, Energy Star 2.0, RoHS, WEEE, REACH
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources