Vertiv GXT5 10KVA 208V UPS - GXT5-10KHVRT5UXLN
10,000 VA / 10,000 W online double-conversion UPS designed for mid-to-large server rooms, network closets, and edge data center deployments where
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv VMBC-20KMVRT4U is a hardwired maintenance bypass cabinet engineered specifically for the GXT5-15KMVRT11UXLN and GXT5-20KMVRT11UXLN rackmount UPS systems. When your data center, server room, or critical-infrastructure installation cannot tolerate downtime for UPS servicing, this bypass cabinet is the mechanical bridge that keeps utility power flowing to your protected loads — allowing the UPS to be isolated, serviced, or swapped without dropping a single load. For facilities engineering teams running 208V/120V three-phase or split-phase distributions where the Vertiv GXT5 line anchors power protection, the VMBC-20KMVRT4U is the purpose-built companion piece, not an afterthought accessory.
Compatible with the broader Vertiv UPS and power protection catalog, this bypass cabinet fits into a managed-maintenance workflow that keeps SLA commitments intact during scheduled and emergency UPS maintenance windows. If you are specifying rackmount UPS systems at the 15–20kVA range, factor this bypass into the initial bill of materials — retrofitting bypass capability after commissioning always costs more in labor and coordination than planning for it upfront.
The VMBC-20KMVRT4U integrates directly into the GXT5 extended-runtime platform — specifically the 11U rackmount chassis variants (GXT5-15KMVRT11UXLN and GXT5-20KMVRT11UXLN). It does not apply to the smaller 2U or 5U GXT5 models, which use their own MP2 or PD5 series bypass and distribution accessories. Cross-referencing the full Vertiv bypass and distribution compatibility matrix before purchasing is important: the same 20kVA nameplate on a different GXT5 chassis variant (such as the HVRT5U or MVRT4U family) maps to a different bypass SKU.
For facilities running a structured rack and power infrastructure, the VMBC-20KMVRT4U is typically installed adjacent to or below the UPS in the same rack column, with the bypass interlocked to prevent simultaneous UPS and bypass conduction. Confirm with your electrical contractor that the hardwired input feed is sized for the full 20kVA load before scheduling the installation window. Consult a UPS and power distribution planning guide if you are still sizing the upstream circuit for this deployment.
Q: Which UPS models is the VMBC-20KMVRT4U compatible with?
A: The VMBC-20KMVRT4U is verified compatible with the GXT5-15KMVRT11UXLN and GXT5-20KMVRT11UXLN rackmount UPS systems. It does not apply to other GXT5 chassis variants such as the 2U, 4U MVRT, 5U HVRT, or L6-20/L6-30 input models — those use separate bypass accessories.
Q: What are the output connectors on the VMBC-20KMVRT4U?
A: The VMBC-20KMVRT4U provides three NEMA L14-30 locking output connectors at 125/250V 30A each. An optional PD2 power distribution pod can be added to expand the outlet mix for loads requiring different connector types.
Q: Does the VMBC-20KMVRT4U require hardwired installation?
A: Yes. The input connection is hardwired (L-L-N-G) at 208V/120V — there is no input plug. Licensed electrical work is required at installation to terminate the input feed. This is standard practice at the 15–20kVA service level.
Q: Can the VMBC-20KMVRT4U support both 120V and 208V loads simultaneously?
A: The NEMA L14-30 connectors support both 125V (line-to-neutral) and 250V (line-to-line) loads. With the optional PD2 POD, you can expand to additional outlet types to serve mixed-voltage downstream equipment from a single bypass cabinet.
Q: What is the bypass capacity of the VMBC-20KMVRT4U?
A: The VMBC-20KMVRT4U is rated at 20,000 VA (20kVA) bypass capacity, which matches the full nameplate rating of the GXT5-20KMVRT11UXLN and exceeds the 15kVA rating of the GXT5-15KMVRT11UXLN — so there is no derating concern at either supported UPS model's maximum load.
Q: Is the VMBC-20KMVRT4U compatible with the GXT5-20KMVRT4UXLN or other 4U GXT5 models?
A: No. The VMBC-20KMVRT4U is specifically designed for the 11U extended-runtime chassis (GXT5-15KMVRT11UXLN and GXT5-20KMVRT11UXLN). The GXT5-5000MVRT4UXLN and GXT5-6000MVRT4UXLN use the PD5-series distribution accessories, not this bypass cabinet.

The VMBC-20KMVRT4U is one of those line items that experienced facilities teams build into the initial PO and less experienced teams forget entirely — until the first scheduled UPS maintenance window arrives and they realize the only path forward is a controlled load shutdown. The hardwired L-L-N-G input and three NEMA L14-30 outputs are the right spec for the 208V/120V service environment the GXT5-15K and 20K UPS models live in, and the 20,000 VA bypass rating means you're not derating when the GXT5-20KMVRT11UXLN is running at nameplate.
Technical Highlights:
Deployment Considerations:
The VMBC-20KMVRT4U earns its place in any data center or network operations center running GXT5 extended-runtime UPS at 15–20kVA where the facility SLA prohibits load drops during UPS maintenance — specifically colocation edge nodes, hospital data closets, and broadcast infrastructure rooms where a four-hour maintenance window with a cold load is simply not an option.