Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric GVSUPS50KB4GS-A 50kW Three-Phase Tower UPS

Overview

The APC by Schneider Electric Galaxy VS GVSUPS50KB4GS-A is a 50 kVA / 50 kW three-phase tower UPS built for data centers, industrial control rooms, and critical facility infrastructure running on 480 V AC power distribution. With a true sine wave output, 0 ms transfer time, and dual internal 9 Ah smart battery modules, this unit keeps sensitive loads online without a blip during utility disturbances — the kind of protection that matters when a sub-cycle voltage sag would otherwise drop a rack of servers or a process controller. If you are sourcing a large commercial UPS for a 480 V three-phase environment and need network-manageable, scalable runtime, the GVSUPS50KB4GS-A belongs on your short list.

Key Features

  • True Sine Wave Output at 480 V / 60 Hz: Outputs a clean sine wave at the same 480 V AC your load expects — no derating required for active PFC power supplies, motor drives, or medical-grade equipment that rejects stepped approximations.
  • 0 ms Transfer Time: The online double-conversion topology means the inverter is always driving the load; there is no transfer gap when utility power fails. For PLCs, RAID controllers, and real-time process systems, this is the spec that separates online UPS from line-interactive alternatives.
  • 50 kVA / 50 kW Capacity: Sized for mid-scale critical loads — a fully populated 10–15 kW server rack cluster, an industrial automation panel, or a distributed surveillance head-end. At unity power factor, kVA equals kW, so you are not losing usable watts to a 0.8 PF derating typical of older UPS designs.
  • 480 V AC Input with Wide 408–552 V Range: The 408–552 V input tolerance absorbs utility sags and swells without switching to battery. Sites with poor power quality or long utility runs benefit directly — fewer unnecessary battery discharge cycles mean longer battery service life.
  • Dual 9 Ah Internal Smart Battery Modules: Two factory-installed 9,000 mAh lead-acid modules provide baseline runtime and support hot-swap replacement without a maintenance shutdown. The 'smart' designation means the UPS actively monitors cell health and flags replacement before a failure occurs.
  • SNMP/Modbus and SNMP/HTTP Network Management: Native support for both SNMP (standard NMS integration — Nagios, SolarWinds, PRTG) and Modbus (BAS and SCADA integration) means this unit fits equally into IT and OT monitoring stacks without a protocol gateway.
  • 61 dB(A) Acoustic Output: At 61 dB(A), this unit is marginal for an open office floor but appropriate for a dedicated equipment room or data hall — set expectations accordingly during site planning.
  • Tower Form Factor, 1,014 lb: The tower enclosure (58.5″ H × 20.5″ W × 33.4″ D) requires floor-level placement with forklift or pallet-jack access during installation. Plan your delivery route and floor load rating (roughly 0.5 ton) before the unit arrives.

Integration and Compatibility

The Galaxy VS communicates via SNMP/HTTP and SNMP/Modbus, making it compatible with standard NMS platforms for IT environments and BAS/SCADA systems common in industrial and building automation deployments. The GVSUPS50KB4GS-A (often searched as GVSUPS50KB4GS A) accepts input frequencies up to 70 Hz and locks output to 60 Hz, ensuring stable frequency for frequency-sensitive loads even on sites with generator-sourced utility. Maximum operating temperature is 40°C (104°F); above that, derate accordingly or provide supplemental cooling. The unit is rated for operation up to 3,229 ft elevation — installations above that threshold require APC derating guidance before commissioning.

Frequently Asked Questions

Q: What is the transfer time on the GVSUPS50KB4GS-A?

A: Zero milliseconds. The Galaxy VS uses an online double-conversion topology, so the inverter is always supplying the load. There is no switching event when utility power fails.

Q: What input voltage range does the GVSUPS50KB4GS-A accept?

A: The unit accepts 480 V AC input with a tolerance range of 408 V to 552 V AC, accommodating common utility voltage sags and swells without switching to battery.

Q: How many batteries are installed, and what is the chemistry?

A: Two internal 9,000 mAh lead-acid smart battery modules are factory-installed. They support active health monitoring and are designed for hot-swap replacement.

Q: What network management protocols does the GVSUPS50KB4GS-A support?

A: SNMP/HTTP for IT network management platforms and SNMP/Modbus for BAS and SCADA integration — both are native, no protocol converter required.

Q: What is the maximum operating elevation for this unit?

A: 3,229 ft (984 m). Installations above this altitude require derating; consult APC application engineering before specifying for high-altitude sites.

Q: What is the warranty on the GVSUPS50KB4GS-A?

A: APC provides a 1-year manufacturer warranty on this unit.

Eden Phillips
Eden Phillips

The GVSUPS50KB4GS-A is the Galaxy VS 50 kW in its 480 V three-phase tower configuration — a unit I would specify specifically for facilities that already run 480 V distribution and need a large UPS that fits into both an IT SNMP monitoring stack and an industrial Modbus SCADA environment simultaneously, without adding a protocol bridge.

Technical Highlights:

  • 0 ms Transfer / Online Double-Conversion: The inverter is always in the power path — there is no break during utility failure. For real-time process controllers and RAID arrays, even a 10 ms gap can trigger a fault condition; this topology eliminates that risk entirely.
  • 408–552 V Input Window: A 35% input swing above and below nominal means the unit stays on utility through sags that would drop a standard UPS to battery. On sites with generator switchover or long feeder runs, this translates directly to fewer battery discharge cycles and longer cell life.
  • Dual SNMP Paths (HTTP + Modbus): Having both SNMP/HTTP and SNMP/Modbus native removes the protocol gateway that typically adds cost, failure points, and latency in hybrid IT/OT environments — relevant in industrial surveillance head-ends or integrated BMS deployments.

Deployment Considerations:

  • At 1,014 lb and 58.5″ tall, this unit requires a forklift or pallet jack for final positioning — confirm your facility's floor load rating (roughly 500 kg point load) and delivery path before scheduling installation.
  • The 3,229 ft operating elevation ceiling is a firm limit; data centers or equipment rooms at altitude (Denver, high-desert sites) need APC derating guidance before this unit is commissioned.

This unit is the right fit for a mid-scale 480 V critical power deployment — a co-location cage, an industrial automation panel room, or a distributed physical security head-end — where dual-protocol management and zero-transfer online topology are non-negotiable requirements.

Specifications
Load Capacity: 50 kVA
Input Voltage: 480 V AC
Input Voltage Range: 408 V AC - 552 V AC
Output Voltage: 480 V AC
Input Frequency: 70 Hz
Output Frequency: 60 Hz
Waveform Type: Sine Wave
Transfer Time: 0 ns
Phase: Three Phase
Network Management: SNMP/Modbus, SNMP/HTTP
DC System Voltage: 480 V DC
Number of Batteries: 2
Battery Chemistry: Lead Acid
Battery Capacity: 9000 mAh
Maximum Operating Temperature: 104°F (40°C)
Storage Temperature: 5°F (-15°C) - 104°F (40°C)
Maximum Operating Elevation: 3229.33 ft
Maximum Storage Elevation: 9842.52 ft
Storage Relative Humidity: 0% - 80%
Sound Emission: 61 dB(A)
Thermal Dissipation: 1526.90 W
Form Factor: Tower
Height: 58.5"
Width: 20.5"
Depth: 33.4"
Weight: 1014.13 lb
Warranty: 1 Year
Q&A
Reviews
Have Questions?

APC by Schneider Electric GVSUPS50KB4GS-A 50kW UPS

$64,610.00
$43,024.99

RELATED PRODUCTS

Save $17,550.01
APC by Schneider Electric Galaxy VS UPS 50KW 480V, 2 Internal 9AH Smart Modular Battery Strings, Expandabl
Add to Cart The item has been added

APC by Schneider Electric GVSUPS50KB4GS

APC by Schneider Electric GVSUPS50KB4GS 50KW UPS

50kW / 50kVA three-phase online double-conversion UPS built for data centers, critical infrastructure, and industrial facilities running on 480V AC

    Usually Ships in 2-3 Weeks Free shipping over $499
    $52,530.00 $34,979.99 Save $17,550.01
    The item has been added Add to quote
    $52,530.00 $34,979.99 Save $17,550.01
    Save $17,550.01 Add to cart Add to quote
    Save $20,171.01
    APC by Schneider Electric Galaxy vs UPS 50KW 480V with N+1 Power Module for 5 - GVSUPS50KR0B5GS
    Add to Cart The item has been added

    APC by Schneider Electric GVSUPS50KR0B5GS

    APC by Schneider Electric GVSUPS50KR0B5GS 50KW UPS

    N N+1 power module designed to provide critical backup power for high-demand applications, specifically supporting 50KW loads at 480V

      Usually Ships in 2-3 Weeks Free shipping over $499
      $60,380.00 $40,208.99 Save $20,171.01
      The item has been added Add to quote
      $60,380.00 $40,208.99 Save $20,171.01
      Save $20,171.01 Add to cart Add to quote

      System Design, Deployment & Technical Support

      Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

      Fixed scope • Fixed price

      System Design Assistance

      • Get help validating product compatibility
      • Coverage requirements
      • Storage planning and deployment architecture before you buy.
      Request Design Help

      Deployment & Configuration Support

      • Access fixed-scope support for rollout planning
      • User setup guidance
      • Migration and system standardization across single-site or multi-site deployments
      View Support Services

      Guides, Tools & Calculators

      • PoE requirements
      • Storage retention
      • Camera selection and deployment methodology
      Open Technical Resources